A novel rotation method with variable-angle anterior probe for correcting the depth of the kidney to optimize renal dynamic imaging

Posted on 2022-11-18 - 12:35
Abstract Purpose We aimed to investigate the effect and significance of the rotation method with variable-angle anterior probe corrected for the depth of two kidneys on the determination of glomerular filtration rate (GFR) in total and single kidneys by the renal dynamic imaging Gates method. Methods Seventy-two patients who underwent dynamic renal imaging by the rotation method and abdominal CT in our hospital were collected in the present study. CT scanning, rotation method, Tonnesen's formula, and Li-Qian's formula were compared in terms of the depth of two kidneys, the depth difference between the two kidneys, and the total renal and single GFR obtained by substituting the renal depth values into Gates' formula. Results ①The depth of kidneys and GFR: Compared to CT, Tonnesen's formula significantly underestimated the depth of both kidneys and the total and single renal GFR (P < 0.05). No significant differences were found in the depth of both kidneys and the total and single renal GFR between Li-Qian's formula and the rotation method (P > 0.05), with a strong agreement and with the least bias in the values measured by the rotation method. ②Renal depth difference: Compared to CT, Tonnesen's formula and Li-Qian's formula underestimated the difference in depth between the two kidneys (P < 0.05). None of the differences were statistically significant based on the rotation method (P > 0.05). The depth difference was positively correlated with the resulting changes in single renal function (|R(CT)-R(Li-Qian)|) and (|R(Rotation)-R(Li-Qian)|) (r = 0.881, 0.641, P < 0.001). As the depth difference increased, Li-Qian's formula could not visualize changes in single renal function accurately. In contrast, the accuracy of the rotation method in assessing single renal function remains unaffected. Conclusion The rotation method obtains an accurate depth and depth difference between the two kidneys without additional CT radiation, enhancing the accuracy of the Gates method for determining total and single renal GFR. Trial registration Medical Ethics Committee of First Hospital of Shanxi Medical University, 2021BAL0146. Registered 12 January 2021.

CITE THIS COLLECTION

DataCite
3 Biotech
3D Printing in Medicine
3D Research
3D-Printed Materials and Systems
4OR
AAPG Bulletin
AAPS Open
AAPS PharmSciTech
Abhandlungen aus dem Mathematischen Seminar der Universität Hamburg
ABI Technik (German)
Academic Medicine
Academic Pediatrics
Academic Psychiatry
Academic Questions
Academy of Management Discoveries
Academy of Management Journal
Academy of Management Learning and Education
Academy of Management Perspectives
Academy of Management Proceedings
Academy of Management Review
or
Select your citation style and then place your mouse over the citation text to select it.

SHARE

email

Usage metrics

EJNMMI Physics

AUTHORS (10)

Hua Wei
Ke Han
Jiaojiao Wu
Guang Hu
Zhifang Wu
Hongliang Wang
Xiaoshan Guo
Yansong Hou
Rui Wang
Sijin Li
need help?