Correlation between Materials, Design and Clinical Issues in the Case of Associated Use of Different Stainless Steels as Implant Materials

Article Preview

Abstract:

Metallic implants for ostheosynthesis are used for temporary replacement of the the original functions and to accelerate the bone consolidation after fracture. Stainless steel is frequently used for bone fracture fixation in spite of its sensitivity to corrosion in aggressive environments such as human body 1. This study is focused on the effect of associated use of various metallic implants for osteosynthesis and the occurrence of local adverse reactions as a tissue response. Once the degradation process occurs metal ions are released and are held responsible for these undesirable effects. This was the main motivation of starting a comprehensive study which involved the clinical data of patients who underwent such surgery, analysis of tissues around the implants and also investigation of metallic explants through microscopy techniques.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

41-44

Citation:

Online since:

September 2013

Export:

Price:

[1] ASM International (2009), Biomaterials in Orthopaedic Surgery.

Google Scholar

[2] ASM International (1990), Properties and Selection: Irons, Steels and High Performance Alloys, Metals Handbook 10th Edition, Vol.1.

DOI: 10.31399/asm.hb.v01.9781627081610

Google Scholar

[3] Holt G, Nunag P, Duncan K, Gregori A. Outcome after short intramedullary nail fixation of unstable proximal femoral fractures. Acta Orthop Belgica 2010;76(3):347–55.

Google Scholar

[4] Kasimatis G, Lambiris E, Tyllianakis M, Giannikas D, Mouzakis D, Panagiotopoulos E. Gamma nail breakage: a report of four cases. J Orthop Surg 2007;15(3):368–72.

DOI: 10.1177/230949900701500326

Google Scholar

[5] Larsson S, Friberg S, Hansson LI. Trochanteric fractures. Mobility, complications, and mortality in 607 cases treated with the sliding-screw technique. Clin Orthop Relat Res 1990;(November (260)):232–41.

DOI: 10.1097/00003086-199011000-00039

Google Scholar

[6] Kuzyk PR, Lobo J, Whelan D, Zdero R, McKee MD, Schemitsch EH. Biomechanical evaluation of extramedullary versus intramedullary fixation for reverse obliquity intertrochanteric fractures. J Orthop Trauma 2009;23(January (1)):31–8.

DOI: 10.1097/bot.0b013e318190ea7d

Google Scholar

[7] Makridis KG, Georgaklis V, Georgoussis M, Mandalos V, Kontogeorgakos VLB. Comparing two intramedullary devices for treating trochanteric fractures: a prospective study. J Orthop Surg Res 2010;5(9):1–8.

DOI: 10.1186/1749-799x-5-9

Google Scholar

[8] Williams W, Parker B. Complications associated with the use of the Gamma nail. Injury 1992;23(5):291–2.

Google Scholar