Study on Ultimate Bearing Capacity and Anti-Slip of the Stud

Article Preview

Abstract:

Based on the test data of twelve push-out specimens with different holes filling different materials,the paper compared and analyzed the capacity and the corresponding slip value of the stud shear connector. The results show that, as to the two different kinds of holes shape ,the strength of the stud shear connectors of square push-out specimens was huger than that of circular specimens with the same condition; the strength of stud shear connectors in steel-concrete composite structure was decided by the strength of concrete surrounding the shear in the holes, with increasing concrete strength, the strength of stud shear connectors improved greatly; The outputs of this study are very useful for further understanding of the characteristics of the stud,it is also expected that the results presented in this paper should be valuable for the design of the composite beams.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

166-169

Citation:

Online since:

September 2011

Export:

Price:

[1] Dai yimin. The composite action and carrying capacities of the composite steel-FDPCP beams under concentrated loads [ J]. Sichuan Building Science Journal,2007, 33(4): 55-58. (in chinese)

Google Scholar

[2] Dai yimin,Li zhengnong. Experimental study on composite steel-precast concrete panel beam [ J]. Journal of Natural Disasters,2006, 15(5): 178-85. (in chinese)

Google Scholar

[3] Dai yimin,Liaosha. Study on composite steel-precast concrete panel beam under concentrated loads [ J]. Building Structure Journal,2007, 37(1): 75-77. (in chinese)

Google Scholar

[4] Nie Jianguo,Yu Zhiwu. Research and practice of steel-concrete composite beams in China[ J]. China Civil Engineering Journal,1999, 32(2): 3-8. (in chinese)

Google Scholar

[5] Xiang Haifan,Wu Dingjun. The present situation and prospect of railwaybridge in China[J]. Railway Construction Technology,2001, (2): 1-6. (in chinese)

Google Scholar

[6] NIE Jianguo, WANG Hongquan, TAN Ying.Experimental study on composite steel-HSC beams[J].Journal of Building Structures, 2004, 25(1): 58-62. (in chinese)

Google Scholar

[7] Liu Li,Wang Lianguang, Shi Guang. Experimental studies on slipbehavior of prestressed steel-HS concrete compositebeams[J]. Journal ofNortheastern University(NaturalScience), 2006, 27(8): 934-936. (in chinese)

Google Scholar

[8] Wang Hongquan. Experimental study on thelongitudinal splitting and flexural strength of composite steel-concrete beams with overlapping flange [D ].Beijing: TsinghuaUniversity, 1996. (in chinese)

Google Scholar

[9] Shim C S, Lee P G, Yoon TY. Static behavior of large stud shear connectors [ J]. Engineering Structures,2004, 26(12): 1853-1860.

DOI: 10.1016/j.engstruct.2004.07.011

Google Scholar

[10] Lee P G, Shim C S, Chang S P. Static and fatigue behavior of large stud shear connectors for steel-concrete composite bridges[ J]. Journal of Constructional Steel Research, 2005, 61(9): 1270-1285

DOI: 10.1016/j.jcsr.2005.01.007

Google Scholar

[11] W illiam K S, Jerome FH, ArturoE S, et a.l Behavior of shear studs in steel frames with reinforced concrete infill walls [ J ]. Journal of Constructional Steel Research, 2004, 60: 1453-1480.

DOI: 10.1016/j.jcsr.2004.03.003

Google Scholar

[12] Byung Hwan Oh,Jae Yeol Cho,Dae Gyun Park.Static and fatigue behavior of reinforced concrete beams strengthened with steel plates for flexure[J].Journal ofStructuralEngineering, 2003,129(4):527-535

DOI: 10.1061/(asce)0733-9445(2003)129:4(527)

Google Scholar