Performance Simulation of External Metal Mesh Screen Devices: A Case Study

Article Preview

Abstract:

Early design decisions with regard to building facade characteristics play a significant role in the resulting building's thermal performance. In this context, external metal mesh screens -used as a permanent second facade skin- are a rather new shading alternative, particularly in non-residential buildings. It has been suggested that such products can filter excessive incident solar radiation while maintaining the facade’s transparent quality. Given the multifaceted implications of this shading device for building energy performance, we undertook a detailed simulation-based study to evaluate the impact of metal mesh screens on annual energy demand for heating, cooling and electric lighting in different European climate zones. Possible design variations were considered in terms of mesh screen translucency, window to wall ratio and facade orientation. The feasibility of using such a shading strategy to provide passive cooling during summer was also explored, along with suitable ventilation scenarios. Toward this end, we examined a number of existing approaches to simulate metal mesh screens and identified their capabilities and limitations. A typical office space was tested in three European locations, taking local building construction standards into account. The results of this study can help planners in their choice of the appropriate shading strategy and provide recommendations for the application of metal mesh screens according to the climatic and architectural criteria.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

151-159

Citation:

Online since:

December 2016

Export:

Price:

* - Corresponding Author

[1] B. Aebischer, G. Catenazzi, M. Jakob, Impact of climate change on thermal comfort, heating and cooling energy demand in Europe, in: ECEEE 2007 Summer Study proceedings Saving energy – Just do it!, La Colle sur Loup, France, 2007, pp.859-870.

Google Scholar

[2] G.S. Eskeland, T.K. Mideksa, Electricity demand in a changing climate, Mitig. Adapt. Strategies Glob. Chang. 15 (8) (2010) pp.877-897.

DOI: 10.1007/s11027-010-9246-x

Google Scholar

[3] A. Watts, Modern Construction Envelopes, SpringerWienNewYork, Vienna, (2011).

Google Scholar

[4] GKD Creativeweave, Mesh types, <http: /www. gkd. de/en/architectural-mesh/mesh-types. html> accessed 11. 10. (2015).

Google Scholar

[5] EnergyPlus Input-Output Reference - The encyclopedic reference to EnergyPlus input and output, U.S. Department of Energy, Washington, (2013).

Google Scholar

[6] T.C. Lam, H. Ge, P. Fazio, Study of different glazing modelling approaches in assessing energy performance of curtain wall systems using EnergyPlus, in: IBPSA-Canada eSIM 2014 conference proceedings, Ottawa, (2014).

Google Scholar

[7] WINDOW 7. 3, <https: /windows. lbl. gov/software/window/window. html> accessed 17. 02. (2015).

Google Scholar

[8] J. Klems, A new method for predicting the solar heat gain of complex fenestration systems. I Overview and derivation of the matrix layer calculation, Am. Soc. Heat. Refrig. Air Cond. Eng. Trans. 100 (1994) p.1065–1072.

DOI: 10.2172/179240

Google Scholar

[9] B. Bueno, J. Wienold, A. Katsifaraki, T.E. Kuhn, Fener: A Radiance-based modelling approach to assess the thermal and daylighting performance of complex fenestration systems in office spaces, Energ. Buildings 94 (2015) pp.10-20.

DOI: 10.1016/j.enbuild.2015.02.038

Google Scholar

[10] R. Mitchell et al., THERM 6. 3 / WINDOW 6. 3 NFRC Simulation Manual, July 2013, <https: /windows. lbl. gov/software/NFRC/SimMan/NFRCSim6. 3-2013-07-Manual. pdf> accessed 28. 08. (2015).

DOI: 10.2172/834262

Google Scholar

[11] CEN, Standard EN15251: Indoor environmental input parameters for design and assessment of energy performance of buildings addressing indoor air quality, thermal environment, lighting and acoustics, European Committee for Standardisation, Brussels, (2007).

DOI: 10.3403/30133865u

Google Scholar

[12] CIBSE, TM 52: The limits of thermal comfort, avoiding overheating in European buildings, The Chartered Institution of Building Services Engineers, London, (2013).

Google Scholar

[13] G. Molina, W. Bustamante, J. Rao, P. Fazio, S. Vera, Evaluation of radiance's genBSDF capability to assess solar bidirectional properties of complex fenestration systems, J. Build. Perform. Simu. 8 (2015) pp.216-225.

DOI: 10.1080/19401493.2014.912355

Google Scholar

[14] L.L. Fernandes, E.S. Lee, A. McNeil, J.C. Jonsson, T. Nouidui, X. Pang, S. Hoffmann, Angular selective window systems: Assessment of technical potential for energy savings, Energ. Buildings 90 (2015) pp.188-206.

DOI: 10.1016/j.enbuild.2014.10.010

Google Scholar