Abstract:

In this paper, a detailed comparison of axi-symmetric and 3D pipe finite element models was carried out under the condition of same welding simulation parameters. Results showed that axi-symmetric model share similar residual stress distribution with 3D model in the condition of same heat source shape parameters. However, the stress values of the two concerned models were different. Meanwhile the scale of welding pool for 3D model was almost twice bigger than that of axi-symmetric model. Both welding experiment and simulation results of 3D model showed that peak temperature of welding pool along the welding path increased during the welding process, and welding pool width and depth also increased with the moving of heat source.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

277-281

Citation:

Online since:

June 2014

Export:

Price:

* - Corresponding Author

[1] B. Brickstad, B.L. Josefson: Int. J. Pres. Ves. Pip. 75 (1998), 11-25.

Google Scholar

[2] M. Mochizuki, M. Hayashi and T. Hattori: Int. J. Pres. Ves. Pip. 122 (2000), 98-103.

Google Scholar

[3] S.W. Wen, P. Hilton and D. Farrugia: J. Mater. Process. Tech. 119 (2001), 203-209.

Google Scholar

[4] D. Gery , H. Long and P. Maropoulos: J. Mater. Process. Tech. 167 (2005), 393-401.

Google Scholar

[5] E. Karadeniz, U. Ozsarac and C. Yildiz: Mater. Design. 28 (2007), 649-656.

Google Scholar

[6] J.W.H. Price, A. Ziara-Paradowska, S. Joshi, T. Finlayson, C. Semetay and H. Nied: Int. J. Mech. Sci. 50 (2008), 513-521.

DOI: 10.1016/j.ijmecsci.2007.08.008

Google Scholar

[7] A. Traidia, F. Roger, E. Guyot, J. Schroeder and G. Lubineau: Int. J. Heat Mass. Tran. 55 (2012), 3946-3963.

DOI: 10.1016/j.ijheatmasstransfer.2012.03.025

Google Scholar

[8] J.C. An, Analysis of the creep crack growth rate in P92 welded joint HAZ, Tianjin university, (2008).

Google Scholar

[9] D. Deng, H. Murakawa: Comp Mater Sci. 37 (2006), 269-277.

Google Scholar

[10] C. Lee, K. Chang: Appl. Therm. Eng. 45-46 (2012), 33-41.

Google Scholar

[11] D. Deng, S. Kiyoshima: Comp. Mater. Sci. 50 (2010), 612-621.

Google Scholar