衝撃荷重を受ける使用済燃料貯蔵容器と鉄筋コンクリート床版の動的相互作用
白井 孝治伊藤 千浩加藤 安久服部 清一三枝 利有大沼 博志
著者情報
ジャーナル フリー

1995 年 37 巻 5 号 p. 430-441

詳細
抄録

Cask-storage is the best method for storing spent fuels at a reactor site. It is necessary to confirm the integrity of a cask subjected to impact load caused by cask mishandling drop accident because it is one of the technical issues to be considered in the safety analysis for cask and storage house.
In this paper, an evaluation method of the dynamic interaction between cask and floor of the Storage facility Subjected to impact load is proposed. Firstly, the cask drop tests onto the reinforced concrete slab representing floor of the storage facility were conducted.
Test results showed that the structural integrity of the cask was maintained even under impact load due to free drop caused by mishandling of cask. Secondly, drop analysis was performed using a finite element method analysis code considering concrete model developed at our laboratory, and compared with the experimental results. As a result, the applicability of this code for drop impact analysis of the cask was confirmed.