2023 年 88 巻 813 号 p. 1513-1524
This paper proposes a design method for M-CK type tuned dynamic mass system considering viscous damping or hysteretic damping of base isolation structure. First, based on the fixed-point theory, the optimal design equation for an M-CK-type tuning system is presented, considering of the viscous damping of the structure. Next, we validate the proposed design method through simulation analysis. Finally, the proposed design method is proved by vibration experiments.