高力ワンサイドボルトを用いた角形鋼管柱-H形はり接合部の構造特性 : 柱はり仕口部分モデルの引張性状
田中 直樹穐山 靖司志村 保美
著者情報
ジャーナル フリー

1997 年 62 巻 495 号 p. 121-128

詳細
抄録

H-beam to box column connections have been ordinary fabricated by the welding method with interior diaphragms. In this method, there are some problems on their fabrication and structural behaviors, because of the complication regarding the details of the welding connections. In this paper, the bolted H-beam to box column connections with split tees and blind bolts are proposed to solve the above problems. Tensile tests were carried out on local models of the connection to understand their structural behaviors. From the tests, it is confirmed that the stiffness and the strength of the connections without diaphragms are improved by covering the column with L-section steel, expanding the distance of bolts, and increasing column thickness. Also the load-displacement relationships can be approximated by the analysis assuming a square frame for column section on the basis of beam theory.

著者関連情報
© 1997 日本建築学会