日本建築学会環境系論文集
Online ISSN : 1881-817X
Print ISSN : 1348-0685
ISSN-L : 1348-0685
コージェネレーションシステムを用いた大学キャンパスにおけるエネルギー調査
-需要側の電力消費量の実態 その2-
張 健許 雷
著者情報
ジャーナル フリー

2012 年 77 巻 673 号 p. 185-192

詳細
抄録

The end-use consumption of electricity in a university campus with co-generation system is investigated. According to the hourly data in classrooms, research laboratory, office rooms, and dining hall, the characteristics for electricity consumption in different buildings are analyzed. The office room consumes the largest amount of electricity of about 124.4kWh/(m2·a), then followed by the dining hall and then the research laboratory, both of about 114 kWh/(m2·a). The classroom consumes the smallest amount of about 60.6kWh/(m2·a). The difference between the peak and off-peak is quite large, and it is 6 times in research laboratory, while it is nearly 20 times in classrooms and dining hall. The duration of peak load is very short, while the operating frequency at partial load is quite high, which leads to large electricity consumption during the partial load rate. Furthermore, the monthly pattern and hour pattern of electricity consumption in different buildings are also analyzed.

著者関連情報
© 2012 日本建築学会
前の記事 次の記事
feedback