Migration patterns of acetabular cups: a systematic review and meta-analysis of RSA studies

Authors

  • Chan Hee Cho Centre for Orthopaedic and Trauma Research, Faculty of Health and Medical Sciences, The University of Adelaide, Adelaide, SA, Australia https://orcid.org/0000-0003-4598-451X
  • Bart G Pijls Department of Orthopaedics, Leiden University Medical Centre, Leiden, Netherlands https://orcid.org/0000-0001-5351-5057
  • John M Abrahams Centre for Orthopaedic and Trauma Research, Faculty of Health and Medical Sciences, The University of Adelaide, Adelaide, SA, Australia; Department of Orthopaedics and Trauma, Royal Adelaide Hospital, Adelaide, SA, Australia
  • Anne Roerink Department of Orthopaedics, Leiden University Medical Centre, Leiden, Netherlands https://orcid.org/0000-0001-8384-4935
  • Raissa Katembwe Centre for Orthopaedic and Trauma Research, Faculty of Health and Medical Sciences, The University of Adelaide, Adelaide, SA, Australia
  • Andrew Baker Centre for Orthopaedic and Trauma Research, Faculty of Health and Medical Sciences, The University of Adelaide, Adelaide, SA, Australia
  • Lucian B Solomon Centre for Orthopaedic and Trauma Research, Faculty of Health and Medical Sciences, The University of Adelaide, Adelaide, SA, Australia; Department of Orthopaedics and Trauma, Royal Adelaide Hospital, Adelaide, SA, Australia
  • Stuart A Callary Centre for Orthopaedic and Trauma Research, Faculty of Health and Medical Sciences, The University of Adelaide, Adelaide, SA, Australia; Department of Orthopaedics and Trauma, Royal Adelaide Hospital, Adelaide, SA, Australia https://orcid.org/0000-0002-2892-5238

DOI:

https://doi.org/10.2340/17453674.2023.24580

Abstract

Background and purpose: We conducted a systematic review and meta-analysis of RSA studies to investigate the early and long-term migration patterns of acetabular cups and the influence of implant factors on cup migration over time.
Methods: We performed a systematic search of PubMed, Embase, and Scopus databases to identify all RSA studies of cup migration following primary total hip replacement (THR). Proximal migration at 3 and 6 months, 1, 2, 5, and 10 years were considered for analysis. Implant factors investigated included fixation type, head size, bearing surface, uncemented coating design, and the decade of RSA introduction.
Results: 47 studies reported the proximal migration of 83 cohorts (2,328 cups). Besides 1 threaded cup design, no implant factor investigated was found to significantly influence proximal migration. The mean pooled 2-year proximal migration of cemented cups (0.14 mm, 95% confidence interval [CI] 0.08–0.20) was not significantly different from uncemented cups (0.12 mm, CI 0.04–0.19). The mean pooled proximal migration at 6 months was 0.11 mm (CI 0.06–0.16) and there was no significant increase between 6 months and 2 years (0.015 mm, CI 0.000–0.030). 27 of 75 cohorts (36%) reported mean proximal migration greater than 0.2 mm at 2 years, which has previously been identified as a predictor of implants at risk of long-term loosening.
Conclusion: Our meta-analysis demonstrated that the majority of cup migration occurs within the first 6 months. With one exception, no implant factors influenced the 2-year proximal migration of acetabular cups. 36% of studies with 2-year migration were considered at risk of long-term loosening. Further investigation and comparison against long-term survivorship data would validate 6-month and/or 1-year proximal migration measurements as an earlier predictor of long-term loosening than the current 2-year threshold.

Downloads

Download data is not yet available.

References

AOANJRR. Australian Orthopaedic Association National Joint Replacement Registry Annual Report 2022. Adelaide: Australian Orthopaedic Association; 2022.

LROI. LROI annual report 2022. Netherlands: Dutch Arthroplasty Register; 2022.

Pijls B G, Nieuwenhuijse M J, Fiocco M, Plevier J W, Middeldorp S, Nelissen R G, et al. Early proximal migration of cups is associated with late revision in THA: a systematic review and meta-analysis of 26 RSA studies and 49 survival studies. Acta Orthop 2012; 83(6): 583-91. doi: 10.3109/17453674.2012.745353. DOI: https://doi.org/10.3109/17453674.2012.745353

Hasan S, Marang-van de Mheen P J, Kaptein B L, Nelissen R, Pijls B G.RSA-tested TKA implants on average have lower mean 10-year revision rates than non-RSA-tested designs. Clin Orthop Relat Res 2020; 478(6): 1232-41. doi: 10.1097/corr.0000000000001209. DOI: https://doi.org/10.1097/CORR.0000000000001209

Nelissen R G, Pijls B G, Kärrholm J, Malchau H, Nieuwenhuijse M J, Valstar E R. RSA and registries: the quest for phased introduction of new implants. J Bone Joint Surg Am 2011; 93(Suppl. 3): 62-5. doi: 10.2106/jbjs.K.00907. DOI: https://doi.org/10.2106/JBJS.K.00907

Malak T T, Broomfield J A, Palmer A J, Hopewell S, Carr A, Brown C, et al. Surrogate markers of long-term outcome in primary total hip arthroplasty: a systematic review. Bone Joint Res 2016; 5(6): 206-14. doi: 10.1302/2046-3758.56.2000568. DOI: https://doi.org/10.1302/2046-3758.56.2000568

Liberati A, Altman D G, Tetzlaff J, Mulrow C, Gøtzsche P C, Ioannidis J P, et al. The PRISMA statement for reporting systematic reviews and meta-analyses of studies that evaluate health care interventions: explanation and elaboration. J Clin Epidemiol 2009; 62(10): e1-e34. doi: DOI: https://doi.org/10.1016/j.jclinepi.2009.06.006

Hasan S, van Dijk L A, Nelissen R G, Plevier J W, Blankevoort L, Pijls B G. RSA migration of unicondylar knee arthroplasties is comparable to migration of total knee arthroplasties: a meta-analysis. J ISAKOS 2022; 7(3): 17-23. doi: 10.1016/j.jisako.2021.12.002. DOI: https://doi.org/10.1016/j.jisako.2021.12.002

Pijls B G, Plevier J W M, Nelissen R. RSA migration of total knee replacements. Acta Orthop 2018; 89(3): 320-8. doi: 10.1080/17453674.2018.1443635. DOI: https://doi.org/10.1080/17453674.2018.1443635

Hozo S P, Djulbegovic B, Hozo I. Estimating the mean and variance from the median, range, and the size of a sample. BMC Med Res Methodol 2005; 5(1): 13. doi: 10.1186/1471-2288-5-13. DOI: https://doi.org/10.1186/1471-2288-5-13

Drevon D, Fursa S R, Malcolm A L. Intercoder reliability and validity of WebPlotDigitizer in extracting graphed data. Behav Modif 2017; 41(2): 323-39. doi: 10.1177/0145445516673998. DOI: https://doi.org/10.1177/0145445516673998

Viechtbauer W. Conducting meta-analyses in R with the metafor package. J Stat Softw 2010; 36(3): 1-48. doi: 10.18637/jss.v036.i03. DOI: https://doi.org/10.18637/jss.v036.i03

Baad-Hansen T, Kold S, Nielsen P T, Laursen M B, Christensen P H, Soballe K. Comparison of trabecular metal cups and titanium fiber-mesh cups in primary hip arthroplasty: a randomized RSA and bone mineral densitometry study of 50 hips. Acta Orthop 2011; 82(2): 155-60. doi: 10.3109/17453674.2011.572251. DOI: https://doi.org/10.3109/17453674.2011.572251

Bergvinsson H, Sundberg M, Flivik G. Polyethylene wear with ceramic and metal femoral heads at 5 years: a randomized controlled trial with radiostereometric analysis. J Arthroplasty 2020; 35(12): 3769-76. doi: 10.1016/j.arth.2020.06.057. DOI: https://doi.org/10.1016/j.arth.2020.06.057

Bergvinsson H, Zampelis V, Sundberg M, Flivik G. Highly cross-linked polyethylene still outperforms conventional polyethylene in THA: 10-year RSA results. Acta Orthop 2021; 92(5): 568-74. doi: 10.1080/17453674.2021.1932140. DOI: https://doi.org/10.1080/17453674.2021.1932140

Bergvinsson H, Zampelis V, Sundberg M, Tjörnstrand J, Flivik G. Vitamin E infused highly cross-linked cemented cups in total hip arthroplasty show good wear pattern and stabilize satisfactorily: a randomized, controlled RSA trial with 5-year follow-up. Acta Orthop 2022; 93: 249-55. doi: 10.2340/17453674.2022.1517. DOI: https://doi.org/10.2340/17453674.2022.1517

Bourne R B, McCalden R W, Naudie D, Charron K D, Yuan X, Holdsworth D W. The next generation of acetabular shell design and bearing surfaces. Orthopedics 2008; 31(12 Suppl. 2). doi:

Carlsson L V, Albrektsson B E J, Albrektsson B G, Albrektsson T O, Jacobsson C M, Macdonald W, et al. Stepwise introduction of a boneconserving osseointegrated hip arthroplasty using RSA and a randomized study: I. Preliminary investigations—52 patients followed for 3 years. Acta Orthop 2006; 77(4): 549-58. doi: 10.1080/17453670610012601. DOI: https://doi.org/10.1080/17453670610012601

Digas G, Kärrholm J, Thanner J, Malchau H, Herberts P. Highly cross-linked polyethylene in cemented THA: randomized study of 61 hips. Clin Orthop Relat Res 2003 (417): 126-38. doi: 10.1097/01.blo.0000096802.78689.45. DOI: https://doi.org/10.1097/01.blo.0000096802.78689.45

Digas G, Kärrholm J, Thanner J, Malchau H, Herberts P. The Otto Aufranc Award. Highly cross-linked polyethylene in total hip arthroplasty: randomized evaluation of penetration rate in cemented and uncemented sockets using radiostereometric analysis. Clin Orthop Relat Res 2004 (429): 6-16. doi: DOI: https://doi.org/10.1097/01.blo.0000150314.70919.e3

Digas G, Thanner J, Anderberg C, Kärrholm J. Bioactive cement or ceramic/porous coating vs. conventional cement to obtain early stability of the acetabular cup: randomised study of 96 hips followed with radiostereometry. J Orthop Res 2004; 22(5): 1035-43. doi: 10.1016/j.orthres.2003.09.012. DOI: https://doi.org/10.1016/j.orthres.2003.09.012

Finnilä S, Moritz N, Svedströ M E, Alm J J, Aro H T. Increased migration of uncemented acetabular cups in female total hip arthroplasty patients with low systemic bone mineral density: a 2-year RSA and 8-year radiographic follow-up study of 34 patients. Acta Orthop 2016; 87(1): 48-54. doi: 10.3109/17453674.2015.1115312. DOI: https://doi.org/10.3109/17453674.2015.1115312

Flatøy B, Rydinge J, Dahl J, Röhrl S M, Nordsletten L. Low wear, high stability: promises of success in a moderately cross-linked cup? Hip Int 2015; 25(3): 199-203. doi: 10.5301/hipint.5000230. DOI: https://doi.org/10.5301/hipint.5000230

Flivik G, Kristiansson I, Ryd L. Positive effect of removal of subchondral bone plate for cemented acetabular component fixation in total hip arthroplasty: a randomised RSA study with ten-year follow-up. Bone Joint J 2015; 97-b(1): 35-44. doi: 10.1302/0301-620x.97b1.34391. DOI: https://doi.org/10.1302/0301-620X.97B1.34391

Flivik G, Sanfridsson J, Önnerfält R, Kesteris U, Ryd L. Migration of the acetabular component: effect of cement pressurization and significance of early radiolucency. Acta Orthop 2005; 76(2): 159-68. doi: 10.1080/00016470510030526. DOI: https://doi.org/10.1080/00016470510030526

Galea V P, Rojanasopondist P, Laursen M, Muratoglu O K, Malchau H, Bragdon C. Evaluation of vitamin E-diffused highly crosslinked polyethylene wear and porous titanium-coated shell stability: a seven-year randomized control trial using radiostereometric analysis. Bone Joint J 2019; 101-b(7): 760-7. doi: 10.1302/0301-620x.101b7.Bjj-2019-0268.R1. DOI: https://doi.org/10.1302/0301-620X.101B7.BJJ-2019-0268.R1

Hjorth M H, Lorenzen N D, Søballe K, Jakobsen S S, Stilling M. Equal primary fixation of resurfacing stem, but inferior cup fixation with anterolateral vs posterior surgical approach: a 2-year blinded randomized radiostereometric and dual-energy x-ray absorptiometry study of metal-on-metal hip resurfacing arthroplasty. J Arthroplasty 2017; 32(11): 3412-20. doi: 10.1016/j.arth.2017.05.034. DOI: https://doi.org/10.1016/j.arth.2017.05.034

Hjorth M H, Søballe K, Jakobsen S S, Lorenzen N D, Mechlenburg I, Stilling M. No association between serum metal ions and implant fixation in large-head metal-on-metal total hip arthroplasty. Acta Orthop 2014; 85(4): 355-62. doi: 10.3109/17453674.2014.922731. DOI: https://doi.org/10.3109/17453674.2014.922731

Howie D W, Holubowycz O T, Callary S A, Robertson T S, Solomon L B. Highly Porous tantalum acetabular components without ancillary screws have similar migration to porous titanium acetabular components with screws at 2 years: a randomized controlled trial. J Arthroplasty 2020; 35(10): 2931-7. doi: 10.1016/j.arth.2020.05.049. DOI: https://doi.org/10.1016/j.arth.2020.05.049

Itayem R, Arndt A, McMinn D J, Daniel J, Lundberg A. A five-year radiostereometric follow-up of the Birmingham Hip Resurfacing arthroplasty. J Bone Joint Surg Br 2007; 89(9): 1140-3. doi: 10.1302/0301-620x.89b9.18367. DOI: https://doi.org/10.1302/0301-620X.89B9.18367

Jacobsen A, Seehaus F, Hong Y, Cao H, Schuh A, Forst R, et al. Model-based roentgen stereophotogrammetric analysis using elementary geometrical shape models: 10 years results of an uncemented acetabular cup component. BMC Musculoskelet Disord 2018; 19(1): 335. doi: 10.1186/s12891-018-2259-4. DOI: https://doi.org/10.1186/s12891-018-2259-4

Jørgensen P B, Daugaard H, Jakobsen S S, Lamm M, Søballe K, Stilling M. Higher early proximal migration of hemispherical cups with electrochemically applied hydroxyapatite (BoneMaster) on a porous surface compared with porous surface alone: a randomized RSA study with 53 patients. Acta Orthop 2020; 91(1): 26-32. doi: 10.1080/17453674.2019.1687860. DOI: https://doi.org/10.1080/17453674.2019.1687860

Kadar T, Hallan G, Aamodt A, Indrekvam K, Badawy M, Skredderstuen A, et al. Wear and migration of highly cross-linked and conventional cemented polyethylene cups with cobalt chrome or Oxinium femoral heads: a randomized radiostereometric study of 150 patients. J Orthop Res 2011; 29(8): 1222-9. doi: 10.1002/jor.21389. DOI: https://doi.org/10.1002/jor.21389

Kjærgaard K, Ding M, Jensen C, Bragdon C, Malchau H, Andreasen C M, et al. Vitamin E-doped total hip arthroplasty liners show similar head penetration to highly cross-linked polyethylene at five years: a multi-arm randomized controlled trial. Bone Joint J 2020; 102-b(10): 1303-10. doi: 10.1302/0301-620x.102b10.Bjj-2020-0138.R1. DOI: https://doi.org/10.1302/0301-620X.102B10.BJJ-2020-0138.R1

Klaassen A D, Schäffer E A, Willigenburg N W, Van Beers L, Scholtes V A B, Van der Hulst V P M, et al. Comparison of early migration patterns between a ceramic and polyethylene liner in uncemented Trabecular Titanium cups: a 2-year randomized controlled trial of 52 hips using radiostereometric analysis. Acta Orthop 2022; 93: 451-8. doi: 10.2340/17453674.2022.2267. DOI: https://doi.org/10.2340/17453674.2022.2267

Laende E K, Richardson C G, Dunbar M J. Migration and wear of a dual mobility acetabular construct at 3 years measured by radiostereometric analysis. J Arthroplasty 2020; 35(4): 1109-16. doi: 10.1016/j.arth.2019.11.010. DOI: https://doi.org/10.1016/j.arth.2019.11.010

Lazarinis S, Milbrink J, Mattsson P, Mallmin H, Hailer N P. Bone loss around a stable, partly threaded hydroxyapatite-coated cup: a prospective cohort study using RSA and DXA. Hip Int 2014; 24(2): 155-66. doi: 10.5301/hipint.5000104. DOI: https://doi.org/10.5301/hipint.5000104

Lindalen E, Dahl J, Nordsletten L, Snorrason F, Høvik Ø, Röhrl S. Reverse hybrid and cemented hip replacement compared using radiostereometry and dual-energy X-ray absorptiometry: 43 hips followed for 2 years in a prospective trial. Acta Orthop 2012; 83(6): 592-8. doi: 10.3109/17453674.2012.742393. DOI: https://doi.org/10.3109/17453674.2012.742393

Minten M J, Heesterbeek P J, Spruit M. No effect of additional screw fixation of a cementless, all-polyethylene press-fit socket on migration, wear, and clinical outcome. Acta Orthop 2016; 87(4): 363-7. doi: 10.1080/17453674.2016.1190244. DOI: https://doi.org/10.1080/17453674.2016.1190244

Munzinger U, Guggi T, Kaptein B, Persoon M, Valstar E, Doets H C. A titanium plasma-sprayed cup with and without hydroxyapatite-coating: a randomised radiostereometric study of stability and osseointegration. Hip Int 2013; 23(1): 33-9. doi: 10.5301/hip.2013.10598. DOI: https://doi.org/10.5301/HIP.2013.10598

Naudie D D, Somerville L, Korczak A, Yuan X, McCalden R W, Holdsworth D, et al. A randomized trial comparing acetabular component fixation of two porous ingrowth surfaces using RSA. J Arthroplasty 2013 ; 28(8 Suppl.): 48-52. doi: 10.1016/j.arth.2013.06.041. DOI: https://doi.org/10.1016/j.arth.2013.06.041

Nilsson K G, Theodoulou A, Mercer G, Quinn S J, Krishnan J. Midterm migration of a cementless, porous acetabular cup: a 5 year radiostereometric analysis. J Orthop 2017; 14(4): 454-60. doi: 10.1016/j.jor.2017.07.004. DOI: https://doi.org/10.1016/j.jor.2017.07.004

Nivbrant B, Kärrholm J, Röhrl S, Hassander H, Wesslén B. Bone cement with reduced proportion of monomer in total hip arthroplasty: preclinical evaluation and randomized study of 47 cases with 5 years’ follow-up. Acta Orthop Scand 2001; 72(6): 572-84. doi: 10.1080/000164701317268987. DOI: https://doi.org/10.1080/000164701317268987

Onsten I, Bengnér U, Besjakov J. Socket migration after Charnley arthroplasty in rheumatoid arthritis and osteoarthritis: a roentgen stereophotogrammetric study. J Bone Joint Surg Br 1993; 75(5): 677-80. doi: 10.1302/0301-620x.75b5.8376420. DOI: https://doi.org/10.1302/0301-620X.75B5.8376420

Onsten I, Carlsson A S. Cemented versus uncemented socket in hip arthroplasty: a radiostereometric study of 60 randomized hips followed for 2 years. Acta Orthop Scand 1994; 65(5): 517-21. doi: 10.3109/17453679409000904. DOI: https://doi.org/10.3109/17453679409000904

Onsten I, Carlsson A S, Sanzén L, Besjakov J. Migration and wear of a hydroxyapatite-coated hip prosthesis: a controlled roentgen stereophotogrammetric study. J Bone Joint Surg Br 1996; 78(1): 85-91. doi: DOI: https://doi.org/10.1302/0301-620X.78B1.0780085

Pakvis D, Luites J, van Hellemondt G, Spruit M. A cementless, elastic press-fit socket with and without screws. Acta Orthop 2012; 83(5): 481-7. doi: 10.3109/17453674.2012.720116. DOI: https://doi.org/10.3109/17453674.2012.720116

Palm L, Olofsson J, åström S-E, Ivarsson I. No difference in migration or wear between cemented low-profile cups and standard cups: a randomized radiostereographic study of 53 patients over 3 years. Acta Orthop 2007; 78(4): 479-84. doi: 10.1080/17453670710014112. DOI: https://doi.org/10.1080/17453670710014112

Röhrl S, Nivbrant B, Mingguo L, Hewitt B. In vivo wear and migration of highly cross-linked polyethylene cups: a radiostereometry analysis study. J Arthroplasty 2005; 20(4): 409-13. doi: 10.1016/j.arth.2004.09.040. DOI: https://doi.org/10.1016/j.arth.2004.09.040

Röhrl S M, Li M G, Nilsson K G, Nivbrant B. Very low wear of non-remelted highly cross-linked polyethylene cups: an RSA study lasting up to 6 years. Acta Orthop 2007; 78(6): 739-45. doi: 10.1080/17453670710014509. DOI: https://doi.org/10.1080/17453670710014509

Röhrl S M, Li M G, Pedersen E, Ullmark G, Nivbrant B. Migration pattern of a short femoral neck preserving stem. Clin Orthop Relat Res 2006 ; 448: 73-8. doi: 10.1097/01.blo.0000224000.87517.4c. DOI: https://doi.org/10.1097/01.blo.0000224000.87517.4c

Röhrl S M, Nivbrant B, Nilsson K G. No adverse effects of submelt-annealed highly crosslinked polyethylene in cemented cups: an RSA study of 8 patients 10 years after surgery. Acta Orthop 2012; 83(2): 14852. doi: 10.3109/17453674.2011.652889. DOI: https://doi.org/10.3109/17453674.2011.652889

Röhrl S M, Nivbrant B, Ström H, Nilsson K G. Effect of augmented cup fixation on stability, wear, and osteolysis: a 5-year follow-up of total hip arthroplasty with RSA. J Arthroplasty 2004; 19(8): 962-71. doi: 10.1016/j.arth.2004.06.024. DOI: https://doi.org/10.1016/S0883-5403(04)00345-6

Salemyr M, Muren O, Eisler T, Bodén H, Chammout G, Stark A, et al. Porous titanium construct cup compared to porous coated titanium cup in total hip arthroplasty: a randomised controlled trial. Int Orthop 2015; 39(5): 823-32. doi: 10.1007/s00264-014-2571-z. DOI: https://doi.org/10.1007/s00264-014-2571-z

Shareghi B, Johanson P E, Kärrholm J. Clinical evaluation of model-based radiostereometric analysis to measure femoral head penetration and cup migration in four different cup designs. J Orthop Res 2017; 35(4): 760-7. doi: 10.1002/jor.23177. DOI: https://doi.org/10.1002/jor.23177

Sillesen N H, Greene M E, Nebergall A K, Nielsen P T, Laursen M B, Troelsen A, et al. Three year RSA evaluation of vitamin e diffused highly cross-linked polyethylene liners and cup stability. J Arthroplasty 2015; 30(7): 1260-4. doi: 10.1016/j.arth.2015.02.018. DOI: https://doi.org/10.1016/j.arth.2015.02.018

Sköldenberg O G, Rysinska A D, Chammout G, Salemyr M, Mukka S S, Bodén H, et al. A randomized double-blind noninferiority trial, evaluating migration of a cemented vitamin E-stabilized highly crosslinked component compared with a standard polyethylene component in reverse hybrid total hip arthroplasty. Bone Joint J 2019; 101-b(10): 1192-8. doi: 10.1302/0301-620x.101b10.Bjj-2019-0456.R2. DOI: https://doi.org/10.1302/0301-620X.101B10.BJJ-2019-0456.R2

Snorrason F, Kärrholm J. Primary migration of fully-threaded acetabular prostheses: a roentgen stereophotogrammetric analysis. J Bone Joint Surg Br 1990; 72(4): 647-52. doi: 10.1302/0301-620x.72b4.2199453. DOI: https://doi.org/10.1302/0301-620X.72B4.2199453

Tabori-Jensen S, Mosegaard S B, Hansen T B, Stilling M. Inferior stabilization of cementless compared with cemented dual-mobility cups in elderly osteoarthrosis patients: a randomized controlled radiostereometry study on 60 patients with 2 years’ follow-up. Acta Orthop 2020; 91(3): 246-53. doi: 10.1080/17453674.2020.1720978. DOI: https://doi.org/10.1080/17453674.2020.1720978

Thanner J, Freij-Larsson C, Kärrholm J, Malchau H, Wesslén B. Evaluation of Boneloc: chemical and mechanical properties, and a randomized clinical study of 30 total hip arthroplasties. Acta Orthop Scand 1995; 66(3): 207-14. doi: 10.3109/17453679508995525. DOI: https://doi.org/10.3109/17453679508995525

Thanner J, Kärrholm J, Herberts P, Malchau H. Hydroxyapatite and tricalcium phosphate-coated cups with and without screw fixation: a randomized study of 64 hips. J Arthroplasty 2000; 15(4): 405-12. doi: 10.1054/arth.2000.2963. DOI: https://doi.org/10.1054/arth.2000.2963

Thanner J, Kärrholm J, Malchau H, Wallinder L, Herberts P. Migration of press-fit cups fixed with poly-L-lactic acid or titanium screws: a randomized study using radiostereometry. J Orthop Res 1996; 14(6): 895-900. doi: 10.1002/jor.1100140608. DOI: https://doi.org/10.1002/jor.1100140608

Thien T M, Ahnfelt L, Eriksson M, Strömberg C, Kärrholm J. Immediate weight bearing after uncemented total hip arthroplasty with an anteverted stem: a prospective randomized comparison using radiostereometry. Acta Orthop 2007; 78(6): 730-8. doi: 10.1080/17453670710014491. DOI: https://doi.org/10.1080/17453670710014491

Thien T M, Thanner J, Kärrholm J. Fixation and bone remodeling around a low-modulus stem: seven-year follow-up of a randomized study with use of radiostereometry and dual-energy X-ray absorptiometer. J Arthroplasty 2012; 27(1): 134-42. e1. doi: DOI: https://doi.org/10.1016/j.arth.2011.03.029

Thoen P S, Nordsletten L, Pripp A H, Röhrl S M. Results of a randomized controlled trial with five-year radiostereometric analysis results of vitamin E-infused highly crosslinked versus moderately crosslinked polyethylene in reverse total hip arthroplasty. Bone Joint J 2020; 102-b(12): 1646-53. doi: 10.1302/0301-620x.102b12.Bjj-2020-0721.R1. DOI: https://doi.org/10.1302/0301-620X.102B12.BJJ-2020-0721.R1

Tsikandylakis G, Mortensen K R L, Gromov K, Troelsen A, Malchau H, Mohaddes M. The use of porous titanium coating and the largest possible head do not affect early cup fixation: a 2-year report from a randomized controlled trial. JB JS Open Access 2020; 5(4). doi: 10.2106/jbjs.Oa.20.00107. DOI: https://doi.org/10.2106/JBJS.OA.20.00107

von Schewelov T, Sanzén L, Onsten I, Carlsson A. Catastrophic failure of an uncemented acetabular component due to high wear and osteolysis: an analysis of 154 omnifit prostheses with mean 6-year follow-up. Acta Orthop Scand 2004; 75(3): 283-94. doi: 10.1080/00016470410001213. DOI: https://doi.org/10.1080/00016470410001213

von Schewelov T, Sanzén L, Onsten I, Carlsson A, Besjakov J. Total hip replacement with a zirconium oxide ceramic femoral head: a randomised roentgen stereophotogrammetric study. J Bone Joint Surg Br 2005; 87(12): 1631-5. doi: 10.1302/0301-620x.87b12.16873. DOI: https://doi.org/10.1302/0301-620X.87B12.16873

Zhou Z K, Li M G, Börlin N, Wood D J, Nivbrant B. No increased migration in cups with ceramic-on-ceramic bearing: an RSA study. Clin Orthop Relat Res 2006; 448: 39-45. doi: 10.1097/01.blo.0000223999.10389.c9. DOI: https://doi.org/10.1097/01.blo.0000223999.10389.c9

Aspenberg P, Wagner P, Nilsson K G, Ranstam J. Fixed or loose? Dichotomy in RSA data for cemented cups. Acta Orthopaedica 2008; 79(4): 467-73. doi: 10.1080/17453670710015445. DOI: https://doi.org/10.1080/17453670710015445

Abrahams J M, Callary S A, Munn Z, Jang S W, Huang Q, Howie D W, et al. Acetabular component migration measured using radiostereometric analysis following revision total hip arthroplasty: a scoping review. JBJS Rev 2020; 8(4): e0170. doi: 10.2106/jbjs.Rvw.19.00170. DOI: https://doi.org/10.2106/JBJS.RVW.19.00170

Valstar E R, Gill R, Ryd L, Flivik G, Börlin N, Kärrholm J. Guidelines for standardization of radiostereometry (RSA) of implants. Acta Orthop 2005; 76(4): 563-72. doi: 10.1080/17453670510041574. DOI: https://doi.org/10.1080/17453670510041574

de Vries L M, van der Weegen W, Pilot P, Stolarczyk P A, Sijbesma T, Hoffman E L. The predictive value of radiostereometric analysis for stem survival in total hip arthroplasty: a systematic review. Hip Int 2014; 24(3): 215-22. doi: 10.5301/hipint.5000102. DOI: https://doi.org/10.5301/hipint.5000102

Finnilä S, Löyttyniemi E, Aro H T. Denosumab in cementless total hip arthroplasty: multivariate reanalysis of 3D femoral stem migration and the influence on outliers. JBMR Plus 2022; 6(2): e10588. doi: https://doi.org/10.1002/jbm4.10588. DOI: https://doi.org/10.1002/jbm4.10588

Published

2023-12-29

How to Cite

Cho, C. H., Pijls, B. G., Abrahams, J. M., Roerink, A., Katembwe, R., Baker, A., Solomon, L. B., & Callary, S. A. (2023). Migration patterns of acetabular cups: a systematic review and meta-analysis of RSA studies. Acta Orthopaedica, 94, 626–634. https://doi.org/10.2340/17453674.2023.24580

Issue

Section

Articles

Categories