日本金属学会誌
Online ISSN : 1880-6880
Print ISSN : 0021-4876
ISSN-L : 0021-4876
鉄の食孔中における塩化物イオンのその場測定
水野 忠彦
著者情報
ジャーナル フリー

1989 年 53 巻 3 号 p. 322-326

詳細
抄録

Pitting corrosion of pure iron in borate buffer solution was studied by in-situ technics using chloride isotope 36Cl. Relationships between chloride ion concentration and current density in pit during pitting corrosion was discussed. Some results are summarized as follows.
(1) Pits growth process is divided into two steps by the variation of chloride ion concentration and pitting current with time.
The first step: chloride ion concentration on a pit surface (γp) increases linearly with time while the current density (ip) stays constant.
The second step: γp stays at a constant, on the other hand, ip decreases gradually with time.
(2) Both of γp and ip increase with external electrode potential.
(3) Also γp and ip increase with a logarithmic low of the chloride ion concentration in a bulk solution.

著者関連情報
© 社団法人 日本金属学会
前の記事 次の記事
feedback
Top