低温工学
Online ISSN : 1880-0408
Print ISSN : 0389-2441
ISSN-L : 0389-2441
ITER-TFインサート・コイルの分流開始温度
布谷 嘉彦杉本 誠礒野 高明濱田 一弥松井 邦浩奥野 清CSモデル・コイル実験グループ
著者情報
ジャーナル フリー

2002 年 37 巻 10 号 p. 523-530

詳細
抄録

The Central Solenoid (CS) model coil program was established in 1992 as one of projects in the Engineering Design Activities (EDA) of the International Thermonuclear Experimental Reacter (ITER). Current sharing temperature (Tcs) measurement of an ITER toroidal field insert (TF insert) was performed. The coil is a Nb3Sn superconducting coil, and was installed inside of the ITER CS model coil as a backup field coil. The relation between the voltage of an individual strand composed of the TF insert conductor and the measured voltage using the taps on the jacket were investigated, and evaluation method for Tcs measurement was established. The obtained results show that there was a discrepancy between the expected value from the strand data and the measured value, which is lower by about 1.2K. Some discrepancy was observed just after cooling down the insert before energizing.

著者関連情報
© 社団法人低温工学協会
前の記事 次の記事
feedback