Technical assessment of BY-1 12 liquid observation well (LOW) anomalous readings
This document contains a technical assessment of the cause and disposition of Interstitial Liquid Level(ILL) readings taken in February 1997 on Hanford waste tank 241-BY-112 that were below specified limits. Some readings were determined to be spurious while other readings were below the limit because of normal data scatter. The data assessment did discover that a new ILL had formed below the currently established baseline because of the normal drainage of the interstitial liquid over time. A new baseline and limit will be established. Because the new ILL appears to be stable and consistent with post saltwell pumping behavior, and because there is no other evidence to the contrary, the tank is judged not to be leaking.
- Research Organization:
- Fluor Daniel Hanford, Inc., Richland, WA (United States)
- Sponsoring Organization:
- USDOE Office of Environmental Restoration and Waste Management, Washington, DC (United States)
- DOE Contract Number:
- AC06-96RL13200
- OSTI ID:
- 326435
- Report Number(s):
- HNF-SD-WM-TA-187; ON: DE98059659; BR: EW3120071; TRN: 97000223
- Resource Relation:
- Other Information: PBD: 11 Mar 1997
- Country of Publication:
- United States
- Language:
- English