skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Liquid Nitrogen Subcooler Pressure Vessel Engineering Note

Technical Report ·
DOI:https://doi.org/10.2172/1032130· OSTI ID:1032130

The normal operating pressure of this dewar is expected to be less than 15 psig. This vessel is open to atmospheric pressure thru a non-isolatable vent line. The backpressure in the vent line was calculated to be less than 1.5 psig at maximum anticipated flow rates.

Research Organization:
Fermi National Accelerator Lab. (FNAL), Batavia, IL (United States)
Sponsoring Organization:
USDOE Office of Science (SC)
DOE Contract Number:
AC02-07CH11359
OSTI ID:
1032130
Report Number(s):
FERMILAB-D0-EN-466; TRN: US1200495
Country of Publication:
United States
Language:
English