抄録

The purpose of the present study was to assess the validity of Piezo-electric accelerometer for estimating energy expenditure in walking and jogging. Energy consumption by oxygen uptake was determined during steady state level of treadmill walking at the speed of 60, 80 and 100 m/min and jogging at the speed of 100, 120, 140, and 160 m/min for 10 subjects. There was a highly significant correlation between the energy consumption and the estimated energy expenditure by an accelerometer despite the attached position (r = 0.912 at the waist, r = 0.915 at the chest, P<0.001), which suggests accurate estimating energy expenditure in the field.