Not logged in
PANGAEA.
Data Publisher for Earth & Environmental Science

Weller, Rolf (2023): Aerosol light absorption coefficients and black carbon concentrations at Neumayer for the year 2021 [dataset]. Alfred Wegener Institute, Helmholtz Centre for Polar and Marine Research, Bremerhaven, PANGAEA, https://doi.org/10.1594/PANGAEA.956089

Always quote citation above when using data! You can download the citation in several formats below.

RIS CitationBibTeX CitationShow MapGoogle Earth

Abstract:
We operate a multi angle absorption photometer MAAP (Model 5012, Thermo Electron Corp.). which is in operation since March 2006 ongoing. This instrument measures atmospheric light absorption by aerosol (mainly caused by black carbon, BC). To this end, ambient aerosol was sampled on a glass filter tape. The measured absorption coefficients abs(637) refer to a wavelength of 637 nm. Raw data were originally sampled in one-minute resolution. Finally, hourly averaged MAAP data are presented here. We also provide BC concentrations (ng/m³) derived from the absorption coefficients using the specific BC attenuation cross section (QBC) of 6.6 m²/g.
Keyword(s):
aerosol; AIRCHEM; Atmospheric chemistry; Spuso
Related to:
Weller, Rolf (2021): Aerosol light absorption coefficients and black carbon concentrations at Neumayer (2006-2020). Alfred Wegener Institute, Helmholtz Centre for Polar and Marine Research, Bremerhaven, PANGAEA, https://doi.org/10.1594/PANGAEA.938991
Project(s):
Coverage:
Latitude: -70.650000 * Longitude: -8.250000
Date/Time Start: 2021-01-01T00:00:00 * Date/Time End: 2022-01-01T00:00:00
Minimum HEIGHT above ground: m * Maximum HEIGHT above ground: m
Event(s):
Neumayer_SPUSO * Latitude: -70.650000 * Longitude: -8.250000 * Date/Time: 1983-01-01T00:00:00 * Elevation: 42.0 m * Location: Dronning Maud Land, Antarctica * Campaign: Neumayer_based * Basis: NEUMAYER III * Method/Device: Air chemistry observatory (SPUSO)
Comment:
Important notice: BC concentrations are extremely low at Neumayer, typically lower than the instrumental noise level referring to 1 hour averages (between 0.04 and 0.05 Mm-1). Notwithstanding, we archived hourly averages, but one has to be aware that negative values may not be removed when smoothing the data or when calculating averages with lower temporal resolution, otherwise the results would exhibit a substantial positive bias!
Parameter(s):
#NameShort NameUnitPrincipal InvestigatorMethod/DeviceComment
1HEIGHT above groundHeightmWeller, RolfGeocode
2DATE/TIMEDate/TimeWeller, RolfGeocode – start
3DATE/TIMEDate/TimeWeller, RolfGeocode – end
4DurationDurationhWeller, Rolf
5Aerosol absorption at 637 nmabs(637)1/MmWeller, RolfMulti angle absorption spectrometer MAAP5012
6Black carbon, aerosolAerosol BCng/m3Weller, RolfMulti angle absorption spectrometer MAAP5012
Status:
Curation Level: Enhanced curation (CurationLevelC)
Size:
26205 data points

Download Data

Download dataset as tab-delimited text — use the following character encoding:

View dataset as HTML (shows only first 2000 rows)