Flores, J Michel; Bourdin, Guillaume; Lombard, Fabien; Koren, Ilan; Vardi, Assaf; Gorsky, G; Moulin, Clémentine; Iwankow, Guillaume; Boissin, Emilie; Poulain, Julie; Romac, Sarah; Agostini, Sylvain; Banaigs, Bernard; Boss, Emmanuel; Bowler, Chris; De Vargas, Colomban; Douville, Eric; Forcioli, Didier; Furla, Paola; Galand, Pierre E; Gilson, Eric; Pesant, Stephane; Reynaud, Stéphanie; Sullivan, Matthew B; Sunagawa, Shinichi; Thomas, Olivier; Troublé, Romain; Vega Thurber, Rebecca; Voolstra, Christian R; Wincker, Patrick; Zoccola, Didier; Allemand, Denis; Planes, Serge (2022): Aerosol concentration and size distribution (25-685nm) measured with a scanning mobility particle sizer [SMPS] during the Tara Pacific Expedition 2016-2018 [dataset]. PANGAEA, https://doi.org/10.1594/PANGAEA.943856
Always quote citation above when using data! You can download the citation in several formats below.
Abstract:
The Tara Pacific expedition (2016-2018) sampled coral ecosystems around 32 islands in the Pacific Ocean, and sampled the surface of oceanic waters at 249 locations, resulting in the collection of nearly 58,000 samples. The expedition was designed to systematically study corals, fish, plankton, and seawater, and included the collection of samples for advanced biogeochemical, molecular, and imaging analysis. Here we provide the continuous dataset originating from scanning mobility particle sizer ([SMPS], SMPS-C GRIMM Aerosol Technik Ainring GmbH & Co. KG, Ainring, Germany) instruments acquiring continuously during the full course of the campaign. Aerosols pumped through one of the ([MAST-PUMP]) inlets were channeled through a conductive tubing of 1.9 cm inner diameter to four parallel 47mm filter holders installed in the rear hold using a vacuum pump (Diaphragm pumpME16 NT, VACUUBRAND BmbH & Co KG, Wertheim, Germany) at a minimum flow rate of 30 lpm (20lpm prior to may 2016). Air was conducted to a scanning mobility particle sizer ([SMPS], SMPS-C GRIMM Aerosol Technik Ainring GmbH & Co. KG, Ainring, Germany) measuring particles in the size range 0.025 – 0.70 µm. The SMPS was set to perform a full scan of particle distribution every 5 min. Data from [SMPS] are averaged at the 30 minute scale and provided both at the scale of particle concentration (nb cm-3) together with its normalized size distribution (dN/dlogDp (nb cm-3) i.e., the concentration divided by the log of the width of the bin).
Related to:
Flores, J Michel; Bourdin, Guillaume; Altaratz, Orit; Trainic, Miri; Lang-Yona, Naama; Dzimban, Edouard; Steinau, Sebastian; Tettich, F; Planes, Serge; Allemand, Denis; Agostini, Sylvain; Banaigs, Bernard; Boissin, Emilie; Boss, Emmanuel; Douville, Eric; Forcioli, Didier; Furla, Paola; Galand, Pierre E; Sullivan, Matthew B; Gilson, Eric; Lombard, Fabien; Moulin, Clémentine; Pesant, Stephane; Poulain, Julie; Reynaud, Stéphanie; Romac, Sarah; Sunagawa, Shinichi; Thomas, Olivier; Troublé, Romain; De Vargas, Colomban; Vega Thurber, Rebecca; Voolstra, Christian R; Wincker, Patrick; Zoccola, Didier; Bowler, Chris; Gorsky, G; Rudich, Yinon; Vardi, Assaf; Koren, Ilan (2020): Tara Pacific Expedition's Atmospheric Measurements of Marine Aerosols across the Atlantic and Pacific Oceans: Overview and Preliminary Results. Bulletin of the American Meteorological Society, 101(5), E536-E554, https://doi.org/10.1175/BAMS-D-18-0224.1
Gorsky, G; Bourdin, Guillaume; Lombard, Fabien; Pedrotti, Maria Luiza; Audrain, Samuel; Bin, Nicolas; Boss, Emmanuel; Bowler, Chris; Cassar, Nicolas; Caudan, Loic; Chabot, Genevieve; Cohen, Natalie R; Cron, Daniel; De Vargas, Colomban; Dolan, John; Douville, Eric; Elineau, A; Flores, J Michel; Ghiglione, Jean Francois; Haëntjens, Nils; Hertau, Martin; John, Seth G; Kelly, Rachel Lauren; Koren, Ilan; Lin, Y; Marie, Dominique; Moulin, Clémentine; Moucherie, Yohann; Pesant, Stephane; Picheral, Marc; Poulain, Julie; Pujo-Pay, Mireille; Reverdin, Gilles; Romac, Sarah; Sullivan, Matthew; Trainic, Miri; Tressol, Marc; Troublé, Romain; Vardi, Assaf; Voolstra, Christian R; Wincker, Patrick; Agostini, Sylvain; Banaigs, Bernard; Boissin, Emilie; Forcioli, Didier; Furla, Paola; Galand, Pierre E; Gilson, Eric; Reynaud, Stéphanie; Sunagawa, Shinichi; Thomas, Olivier; Vega Thurber, Rebecca; Zoccola, Didier; Tara Pacific Consortium; Planes, Serge; Allemand, Denis; Karsenti, Eric (2019): Expanding Tara Oceans Protocols for Underway, Ecosystemic Sampling of the Ocean-Atmosphere Interface During Tara Pacific Expedition (2016–2018). Frontiers in Marine Science, 6, https://doi.org/10.3389/fmars.2019.00750
Lombard, Fabien; Bourdin, Guillaume; Pesant, Stephane; Agostini, Sylvain; Baudena, Alberto; Boissin, Emilie; Cassar, Nicolas; Clampitt, Megan; Conan, Pascal; Da Silva, Ophélie; Dimier, Céline; Douville, Eric; Elineau, A; Fin, Jonathan; Flores, J Michel; Ghiglione, Jean Francois; Hume, Benjamin C C; Jalabert, Laetitia; John, Seth G; Kelly, Rachel Lauren; Koren, Ilan; Lin, Yajuan; Marie, Dominique; McMinds, Ryan; Meriguet, Zoe; Metzl, Nicolas; Paz-Garcíax, David A; Pedrotti, Maria Luiza; Poulain, Julie; Pujo-Pay, Mireille; Ras, Josephine; Reverdin, Gilles; Romac, Sarah; Rouan, Alice; Röttinger, Eric; Vardi, Assaf; Voolstra, Christian R; Moulin, Clémentine; Iwankow, Guillaume; Banaigs, Bernard; Bowler, Chris; De Vargas, Colomban; Forcioli, Didier; Furla, Paola; Galand, Pierre E; Gilson, Eric; Reynaud, Stéphanie; Sunagawa, Shinichi; Sullivan, Matthew B; Thomas, Olivier; Troublé, Romain; Vega Thurber, Rebecca; Wincker, Patrick; Zoccola, Didier; Allemand, Denis; Planes, Serge; Boss, Emmanuel; Gorsky, G (2023): Open science resources from the Tara Pacific expedition across coral reef and surface ocean ecosystems. Scientific Data, 10(1), 324, https://doi.org/10.1038/s41597-022-01757-w
Planes, Serge; Allemand, Denis; Agostini, Sylvain; Banaigs, Bernard; Boissin, Emilie; Boss, Emmanuel; Bourdin, Guillaume; Bowler, Chris; Douville, Eric; Flores, J Michel; Forcioli, Didier; Furla, Paola; Galand, Pierre E; Ghiglione, Jean Francois; Gilson, Eric; Lombard, Fabien; Moulin, Clémentine; Pesant, Stephane; Poulain, Julie; Reynaud, Stéphanie; Romac, Sarah; Sullivan, Matthew B; Sunagawa, Shinichi; Thomas, Olivier; Troublé, Romain; De Vargas, Colomban; Vega Thurber, Rebecca; Voolstra, Christian R; Wincker, Patrick; Zoccola, Didier; Tara Pacific Consortium (2019): The Tara Pacific expedition - A pan-ecosystemic approach of the “-omics” complexity of coral reef holobionts across the Pacific Ocean. PLoS Biology, 17(9), e3000483, https://doi.org/10.1371/journal.pbio.3000483
Project(s):
Fondation Tara Expeditions (FondTara)
Tara Pacific Expedition (Tara_Pacific)
Coverage:
Median Latitude: 19.644709 * Median Longitude: 175.789631 * South-bound Latitude: -22.274205 * West-bound Longitude: 109.459625 * North-bound Latitude: 51.701460 * East-bound Longitude: -3.356767
Date/Time Start: 2016-05-28T13:24:00 * Date/Time End: 2018-10-28T13:30:00
Event(s):
TARA_2016-2018 * Location: Pacific Ocean * Campaign: TARA_PACIFIC_2016-2018 * Basis: SV Tara * Method/Device: Underway, multiple sensors (UMS)
Parameter(s):
# | Name | Short Name | Unit | Principal Investigator | Method/Device | Comment |
---|---|---|---|---|---|---|
1 | DATE/TIME | Date/Time | Lombard, Fabien | Geocode – UTC | ||
2 | LATITUDE | Latitude | Lombard, Fabien | Geocode | ||
3 | LONGITUDE | Longitude | Lombard, Fabien | Geocode | ||
4 | Time in minutes | Time | min | Lombard, Fabien | Duration | |
5 | Particle number, total | CP_conc tot | #/cm3 | Lombard, Fabien | Optical particle counter ([EDM]; EDM180 GRIMM Aerosol Technik Ainring GmbH & Co. KG, Ainring, Germany) measuring and counting particles in 30 minutes average | Total |
6 | Particle concentration, standard deviation | Part conc std dev | ± | Lombard, Fabien | Optical particle counter ([EDM]; EDM180 GRIMM Aerosol Technik Ainring GmbH & Co. KG, Ainring, Germany) measuring and counting particles in 30 minutes average | Total |
7 | Log-normal particle size distribution, normalized concentration at particle diameter 25.03 nm | dN/dlogDp(25.03) | #/cm3 | Lombard, Fabien | Optical particle counter ([EDM]; EDM180 GRIMM Aerosol Technik Ainring GmbH & Co. KG, Ainring, Germany) measuring and counting particles in 30 minutes average | |
8 | Log-normal particle size distribution, normalized concentration at particle diameter 25.95 nm | dN/dlogDp(25.95) | #/cm3 | Lombard, Fabien | Optical particle counter ([EDM]; EDM180 GRIMM Aerosol Technik Ainring GmbH & Co. KG, Ainring, Germany) measuring and counting particles in 30 minutes average | |
9 | Log-normal particle size distribution, normalized concentration at particle diameter 26.9 nm | dN/dlogDp(26.9) | #/cm3 | Lombard, Fabien | Optical particle counter ([EDM]; EDM180 GRIMM Aerosol Technik Ainring GmbH & Co. KG, Ainring, Germany) measuring and counting particles in 30 minutes average | |
10 | Log-normal particle size distribution, normalized concentration at particle diameter 27.88 nm | dN/dlogDp(27.88) | #/cm3 | Lombard, Fabien | Optical particle counter ([EDM]; EDM180 GRIMM Aerosol Technik Ainring GmbH & Co. KG, Ainring, Germany) measuring and counting particles in 30 minutes average | |
11 | Log-normal particle size distribution, normalized concentration at particle diameter 28.9 nm | dN/dlogDp(28.9) | #/cm3 | Lombard, Fabien | Optical particle counter ([EDM]; EDM180 GRIMM Aerosol Technik Ainring GmbH & Co. KG, Ainring, Germany) measuring and counting particles in 30 minutes average | |
12 | Log-normal particle size distribution, normalized concentration at particle diameter 29.96 nm | dN/dlogDp(29.96) | #/cm3 | Lombard, Fabien | Optical particle counter ([EDM]; EDM180 GRIMM Aerosol Technik Ainring GmbH & Co. KG, Ainring, Germany) measuring and counting particles in 30 minutes average | |
13 | Log-normal particle size distribution, normalized concentration at particle diameter 31.06 nm | dN/dlogDp(31.06) | #/cm3 | Lombard, Fabien | Optical particle counter ([EDM]; EDM180 GRIMM Aerosol Technik Ainring GmbH & Co. KG, Ainring, Germany) measuring and counting particles in 30 minutes average | |
14 | Log-normal particle size distribution, normalized concentration at particle diameter 32.2 nm | dN/dlogDp(32.2) | #/cm3 | Lombard, Fabien | Optical particle counter ([EDM]; EDM180 GRIMM Aerosol Technik Ainring GmbH & Co. KG, Ainring, Germany) measuring and counting particles in 30 minutes average | |
15 | Log-normal particle size distribution, normalized concentration at particle diameter 33.38 nm | dN/dlogDp(33.38) | #/cm3 | Lombard, Fabien | Optical particle counter ([EDM]; EDM180 GRIMM Aerosol Technik Ainring GmbH & Co. KG, Ainring, Germany) measuring and counting particles in 30 minutes average | |
16 | Log-normal particle size distribution, normalized concentration at particle diameter 34.6 nm | dN/dlogDp(34.6) | #/cm3 | Lombard, Fabien | Optical particle counter ([EDM]; EDM180 GRIMM Aerosol Technik Ainring GmbH & Co. KG, Ainring, Germany) measuring and counting particles in 30 minutes average | |
17 | Log-normal particle size distribution, normalized concentration at particle diameter 35.87 nm | dN/dlogDp(35.87) | #/cm3 | Lombard, Fabien | Optical particle counter ([EDM]; EDM180 GRIMM Aerosol Technik Ainring GmbH & Co. KG, Ainring, Germany) measuring and counting particles in 30 minutes average | |
18 | Log-normal particle size distribution, normalized concentration at particle diameter 37.18 nm | dN/dlogDp(37.18) | #/cm3 | Lombard, Fabien | Optical particle counter ([EDM]; EDM180 GRIMM Aerosol Technik Ainring GmbH & Co. KG, Ainring, Germany) measuring and counting particles in 30 minutes average | |
19 | Log-normal particle size distribution, normalized concentration at particle diameter 38.54 nm | dN/dlogDp(38.54) | #/cm3 | Lombard, Fabien | Optical particle counter ([EDM]; EDM180 GRIMM Aerosol Technik Ainring GmbH & Co. KG, Ainring, Germany) measuring and counting particles in 30 minutes average | |
20 | Log-normal particle size distribution, normalized concentration at particle diameter 39.95 nm | dN/dlogDp(39.95) | #/cm3 | Lombard, Fabien | Optical particle counter ([EDM]; EDM180 GRIMM Aerosol Technik Ainring GmbH & Co. KG, Ainring, Germany) measuring and counting particles in 30 minutes average | |
21 | Log-normal particle size distribution, normalized concentration at particle diameter 41.42 nm | dN/dlogDp(41.42) | #/cm3 | Lombard, Fabien | Optical particle counter ([EDM]; EDM180 GRIMM Aerosol Technik Ainring GmbH & Co. KG, Ainring, Germany) measuring and counting particles in 30 minutes average | |
22 | Log-normal particle size distribution, normalized concentration at particle diameter 42.94 nm | dN/dlogDp(42.94) | #/cm3 | Lombard, Fabien | Optical particle counter ([EDM]; EDM180 GRIMM Aerosol Technik Ainring GmbH & Co. KG, Ainring, Germany) measuring and counting particles in 30 minutes average | |
23 | Log-normal particle size distribution, normalized concentration at particle diameter 44.51 nm | dN/dlogDp(44.51) | #/cm3 | Lombard, Fabien | Optical particle counter ([EDM]; EDM180 GRIMM Aerosol Technik Ainring GmbH & Co. KG, Ainring, Germany) measuring and counting particles in 30 minutes average | |
24 | Log-normal particle size distribution, normalized concentration at particle diameter 46.14 nm | dN/dlogDp(46.14) | #/cm3 | Lombard, Fabien | Optical particle counter ([EDM]; EDM180 GRIMM Aerosol Technik Ainring GmbH & Co. KG, Ainring, Germany) measuring and counting particles in 30 minutes average | |
25 | Log-normal particle size distribution, normalized concentration at particle diameter 47.83 nm | dN/dlogDp(47.83) | #/cm3 | Lombard, Fabien | Optical particle counter ([EDM]; EDM180 GRIMM Aerosol Technik Ainring GmbH & Co. KG, Ainring, Germany) measuring and counting particles in 30 minutes average | |
26 | Log-normal particle size distribution, normalized concentration at particle diameter 49.58 nm | dN/dlogDp(49.58) | #/cm3 | Lombard, Fabien | Optical particle counter ([EDM]; EDM180 GRIMM Aerosol Technik Ainring GmbH & Co. KG, Ainring, Germany) measuring and counting particles in 30 minutes average | |
27 | Log-normal particle size distribution, normalized concentration at particle diameter 51.4 nm | dN/dlogDp(51.4) | #/cm3 | Lombard, Fabien | Optical particle counter ([EDM]; EDM180 GRIMM Aerosol Technik Ainring GmbH & Co. KG, Ainring, Germany) measuring and counting particles in 30 minutes average | |
28 | Log-normal particle size distribution, normalized concentration at particle diameter 53.28 nm | dN/dlogDp(53.28) | #/cm3 | Lombard, Fabien | Optical particle counter ([EDM]; EDM180 GRIMM Aerosol Technik Ainring GmbH & Co. KG, Ainring, Germany) measuring and counting particles in 30 minutes average | |
29 | Log-normal particle size distribution, normalized concentration at particle diameter 55.23 nm | dN/dlogDp(55.23) | #/cm3 | Lombard, Fabien | Optical particle counter ([EDM]; EDM180 GRIMM Aerosol Technik Ainring GmbH & Co. KG, Ainring, Germany) measuring and counting particles in 30 minutes average | |
30 | Log-normal particle size distribution, normalized concentration at particle diameter 57.25 nm | dN/dlogDp(57.25) | #/cm3 | Lombard, Fabien | Optical particle counter ([EDM]; EDM180 GRIMM Aerosol Technik Ainring GmbH & Co. KG, Ainring, Germany) measuring and counting particles in 30 minutes average | |
31 | Log-normal particle size distribution, normalized concentration at particle diameter 59.35 nm | dN/dlogDp(59.35) | #/cm3 | Lombard, Fabien | Optical particle counter ([EDM]; EDM180 GRIMM Aerosol Technik Ainring GmbH & Co. KG, Ainring, Germany) measuring and counting particles in 30 minutes average | |
32 | Log-normal particle size distribution, normalized concentration at particle diameter 61.53 nm | dN/dlogDp(61.53) | #/cm3 | Lombard, Fabien | Optical particle counter ([EDM]; EDM180 GRIMM Aerosol Technik Ainring GmbH & Co. KG, Ainring, Germany) measuring and counting particles in 30 minutes average | |
33 | Log-normal particle size distribution, normalized concentration at particle diameter 63.78 nm | dN/dlogDp(63.78) | #/cm3 | Lombard, Fabien | Optical particle counter ([EDM]; EDM180 GRIMM Aerosol Technik Ainring GmbH & Co. KG, Ainring, Germany) measuring and counting particles in 30 minutes average | |
34 | Log-normal particle size distribution, normalized concentration at particle diameter 66.12 nm | dN/dlogDp(66.12) | #/cm3 | Lombard, Fabien | Optical particle counter ([EDM]; EDM180 GRIMM Aerosol Technik Ainring GmbH & Co. KG, Ainring, Germany) measuring and counting particles in 30 minutes average | |
35 | Log-normal particle size distribution, normalized concentration at particle diameter 68.54 nm | dN/dlogDp(68.54) | #/cm3 | Lombard, Fabien | Optical particle counter ([EDM]; EDM180 GRIMM Aerosol Technik Ainring GmbH & Co. KG, Ainring, Germany) measuring and counting particles in 30 minutes average | |
36 | Log-normal particle size distribution, normalized concentration at particle diameter 71.05 nm | dN/dlogDp(71.05) | #/cm3 | Lombard, Fabien | Optical particle counter ([EDM]; EDM180 GRIMM Aerosol Technik Ainring GmbH & Co. KG, Ainring, Germany) measuring and counting particles in 30 minutes average | |
37 | Log-normal particle size distribution, normalized concentration at particle diameter 73.65 nm | dN/dlogDp(73.65) | #/cm3 | Lombard, Fabien | Optical particle counter ([EDM]; EDM180 GRIMM Aerosol Technik Ainring GmbH & Co. KG, Ainring, Germany) measuring and counting particles in 30 minutes average | |
38 | Log-normal particle size distribution, normalized concentration at particle diameter 76.35 nm | dN/dlogDp(76.35) | #/cm3 | Lombard, Fabien | Optical particle counter ([EDM]; EDM180 GRIMM Aerosol Technik Ainring GmbH & Co. KG, Ainring, Germany) measuring and counting particles in 30 minutes average | |
39 | Log-normal particle size distribution, normalized concentration at particle diameter 79.15 nm | dN/dlogDp(79.15) | #/cm3 | Lombard, Fabien | Optical particle counter ([EDM]; EDM180 GRIMM Aerosol Technik Ainring GmbH & Co. KG, Ainring, Germany) measuring and counting particles in 30 minutes average | |
40 | Log-normal particle size distribution, normalized concentration at particle diameter 82.05 nm | dN/dlogDp(82.05) | #/cm3 | Lombard, Fabien | Optical particle counter ([EDM]; EDM180 GRIMM Aerosol Technik Ainring GmbH & Co. KG, Ainring, Germany) measuring and counting particles in 30 minutes average | |
41 | Log-normal particle size distribution, normalized concentration at particle diameter 85.05 nm | dN/dlogDp(85.05) | #/cm3 | Lombard, Fabien | Optical particle counter ([EDM]; EDM180 GRIMM Aerosol Technik Ainring GmbH & Co. KG, Ainring, Germany) measuring and counting particles in 30 minutes average | |
42 | Log-normal particle size distribution, normalized concentration at particle diameter 88.17 nm | dN/dlogDp(88.17) | #/cm3 | Lombard, Fabien | Optical particle counter ([EDM]; EDM180 GRIMM Aerosol Technik Ainring GmbH & Co. KG, Ainring, Germany) measuring and counting particles in 30 minutes average | |
43 | Log-normal particle size distribution, normalized concentration at particle diameter 91.4 nm | dN/dlogDp(91.4) | #/cm3 | Lombard, Fabien | Optical particle counter ([EDM]; EDM180 GRIMM Aerosol Technik Ainring GmbH & Co. KG, Ainring, Germany) measuring and counting particles in 30 minutes average | |
44 | Log-normal particle size distribution, normalized concentration at particle diameter 94.75 nm | dN/dlogDp(94.75) | #/cm3 | Lombard, Fabien | Optical particle counter ([EDM]; EDM180 GRIMM Aerosol Technik Ainring GmbH & Co. KG, Ainring, Germany) measuring and counting particles in 30 minutes average | |
45 | Log-normal particle size distribution, normalized concentration at particle diameter 98.22 nm | dN/dlogDp(98.22) | #/cm3 | Lombard, Fabien | Optical particle counter ([EDM]; EDM180 GRIMM Aerosol Technik Ainring GmbH & Co. KG, Ainring, Germany) measuring and counting particles in 30 minutes average | |
46 | Log-normal particle size distribution, normalized concentration at particle diameter 101.82 nm | dN/dlogDp(101.82) | #/cm3 | Lombard, Fabien | Optical particle counter ([EDM]; EDM180 GRIMM Aerosol Technik Ainring GmbH & Co. KG, Ainring, Germany) measuring and counting particles in 30 minutes average | |
47 | Log-normal particle size distribution, normalized concentration at particle diameter 105.54 nm | dN/dlogDp(105.54) | #/cm3 | Lombard, Fabien | Optical particle counter ([EDM]; EDM180 GRIMM Aerosol Technik Ainring GmbH & Co. KG, Ainring, Germany) measuring and counting particles in 30 minutes average | |
48 | Log-normal particle size distribution, normalized concentration at particle diameter 109.41 nm | dN/dlogDp(109.41) | #/cm3 | Lombard, Fabien | Optical particle counter ([EDM]; EDM180 GRIMM Aerosol Technik Ainring GmbH & Co. KG, Ainring, Germany) measuring and counting particles in 30 minutes average | |
49 | Log-normal particle size distribution, normalized concentration at particle diameter 113.42 nm | dN/dlogDp(113.42) | #/cm3 | Lombard, Fabien | Optical particle counter ([EDM]; EDM180 GRIMM Aerosol Technik Ainring GmbH & Co. KG, Ainring, Germany) measuring and counting particles in 30 minutes average | |
50 | Log-normal particle size distribution, normalized concentration at particle diameter 117.57 nm | dN/dlogDp(117.57) | #/cm3 | Lombard, Fabien | Optical particle counter ([EDM]; EDM180 GRIMM Aerosol Technik Ainring GmbH & Co. KG, Ainring, Germany) measuring and counting particles in 30 minutes average | |
51 | Log-normal particle size distribution, normalized concentration at particle diameter 121.88 nm | dN/dlogDp(121.88) | #/cm3 | Lombard, Fabien | Optical particle counter ([EDM]; EDM180 GRIMM Aerosol Technik Ainring GmbH & Co. KG, Ainring, Germany) measuring and counting particles in 30 minutes average | |
52 | Log-normal particle size distribution, normalized concentration at particle diameter 126.35 nm | dN/dlogDp(126.35) | #/cm3 | Lombard, Fabien | Optical particle counter ([EDM]; EDM180 GRIMM Aerosol Technik Ainring GmbH & Co. KG, Ainring, Germany) measuring and counting particles in 30 minutes average | |
53 | Log-normal particle size distribution, normalized concentration at particle diameter 130.97 nm | dN/dlogDp(130.97) | #/cm3 | Lombard, Fabien | Optical particle counter ([EDM]; EDM180 GRIMM Aerosol Technik Ainring GmbH & Co. KG, Ainring, Germany) measuring and counting particles in 30 minutes average | |
54 | Log-normal particle size distribution, normalized concentration at particle diameter 135.77 nm | dN/dlogDp(135.77) | #/cm3 | Lombard, Fabien | Optical particle counter ([EDM]; EDM180 GRIMM Aerosol Technik Ainring GmbH & Co. KG, Ainring, Germany) measuring and counting particles in 30 minutes average | |
55 | Log-normal particle size distribution, normalized concentration at particle diameter 140.75 nm | dN/dlogDp(140.75) | #/cm3 | Lombard, Fabien | Optical particle counter ([EDM]; EDM180 GRIMM Aerosol Technik Ainring GmbH & Co. KG, Ainring, Germany) measuring and counting particles in 30 minutes average | |
56 | Log-normal particle size distribution, normalized concentration at particle diameter 145.9 nm | dN/dlogDp(145.9) | #/cm3 | Lombard, Fabien | Optical particle counter ([EDM]; EDM180 GRIMM Aerosol Technik Ainring GmbH & Co. KG, Ainring, Germany) measuring and counting particles in 30 minutes average | |
57 | Log-normal particle size distribution, normalized concentration at particle diameter 151.25 nm | dN/dlogDp(151.25) | #/cm3 | Lombard, Fabien | Optical particle counter ([EDM]; EDM180 GRIMM Aerosol Technik Ainring GmbH & Co. KG, Ainring, Germany) measuring and counting particles in 30 minutes average | |
58 | Log-normal particle size distribution, normalized concentration at particle diameter 156.79 nm | dN/dlogDp(156.79) | #/cm3 | Lombard, Fabien | Optical particle counter ([EDM]; EDM180 GRIMM Aerosol Technik Ainring GmbH & Co. KG, Ainring, Germany) measuring and counting particles in 30 minutes average | |
59 | Log-normal particle size distribution, normalized concentration at particle diameter 162.53 nm | dN/dlogDp(162.53) | #/cm3 | Lombard, Fabien | Optical particle counter ([EDM]; EDM180 GRIMM Aerosol Technik Ainring GmbH & Co. KG, Ainring, Germany) measuring and counting particles in 30 minutes average | |
60 | Log-normal particle size distribution, normalized concentration at particle diameter 168.49 nm | dN/dlogDp(168.49) | #/cm3 | Lombard, Fabien | Optical particle counter ([EDM]; EDM180 GRIMM Aerosol Technik Ainring GmbH & Co. KG, Ainring, Germany) measuring and counting particles in 30 minutes average | |
61 | Log-normal particle size distribution, normalized concentration at particle diameter 174.66 nm | dN/dlogDp(174.66) | #/cm3 | Lombard, Fabien | Optical particle counter ([EDM]; EDM180 GRIMM Aerosol Technik Ainring GmbH & Co. KG, Ainring, Germany) measuring and counting particles in 30 minutes average | |
62 | Log-normal particle size distribution, normalized concentration at particle diameter 181.06 nm | dN/dlogDp(181.06) | #/cm3 | Lombard, Fabien | Optical particle counter ([EDM]; EDM180 GRIMM Aerosol Technik Ainring GmbH & Co. KG, Ainring, Germany) measuring and counting particles in 30 minutes average | |
63 | Log-normal particle size distribution, normalized concentration at particle diameter 187.69 nm | dN/dlogDp(187.69) | #/cm3 | Lombard, Fabien | Optical particle counter ([EDM]; EDM180 GRIMM Aerosol Technik Ainring GmbH & Co. KG, Ainring, Germany) measuring and counting particles in 30 minutes average | |
64 | Log-normal particle size distribution, normalized concentration at particle diameter 194.56 nm | dN/dlogDp(194.56) | #/cm3 | Lombard, Fabien | Optical particle counter ([EDM]; EDM180 GRIMM Aerosol Technik Ainring GmbH & Co. KG, Ainring, Germany) measuring and counting particles in 30 minutes average | |
65 | Log-normal particle size distribution, normalized concentration at particle diameter 201.69 nm | dN/dlogDp(201.69) | #/cm3 | Lombard, Fabien | Optical particle counter ([EDM]; EDM180 GRIMM Aerosol Technik Ainring GmbH & Co. KG, Ainring, Germany) measuring and counting particles in 30 minutes average | |
66 | Log-normal particle size distribution, normalized concentration at particle diameter 209.08 nm | dN/dlogDp(209.08) | #/cm3 | Lombard, Fabien | Optical particle counter ([EDM]; EDM180 GRIMM Aerosol Technik Ainring GmbH & Co. KG, Ainring, Germany) measuring and counting particles in 30 minutes average | |
67 | Log-normal particle size distribution, normalized concentration at particle diameter 216.74 nm | dN/dlogDp(216.74) | #/cm3 | Lombard, Fabien | Optical particle counter ([EDM]; EDM180 GRIMM Aerosol Technik Ainring GmbH & Co. KG, Ainring, Germany) measuring and counting particles in 30 minutes average | |
68 | Log-normal particle size distribution, normalized concentration at particle diameter 224.68 nm | dN/dlogDp(224.68) | #/cm3 | Lombard, Fabien | Optical particle counter ([EDM]; EDM180 GRIMM Aerosol Technik Ainring GmbH & Co. KG, Ainring, Germany) measuring and counting particles in 30 minutes average | |
69 | Log-normal particle size distribution, normalized concentration at particle diameter 232.91 nm | dN/dlogDp(232.91) | #/cm3 | Lombard, Fabien | Optical particle counter ([EDM]; EDM180 GRIMM Aerosol Technik Ainring GmbH & Co. KG, Ainring, Germany) measuring and counting particles in 30 minutes average | |
70 | Log-normal particle size distribution, normalized concentration at particle diameter 241.44 nm | dN/dlogDp(241.44) | #/cm3 | Lombard, Fabien | Optical particle counter ([EDM]; EDM180 GRIMM Aerosol Technik Ainring GmbH & Co. KG, Ainring, Germany) measuring and counting particles in 30 minutes average | |
71 | Log-normal particle size distribution, normalized concentration at particle diameter 250.29 nm | dN/dlogDp(250.29) | #/cm3 | Lombard, Fabien | Optical particle counter ([EDM]; EDM180 GRIMM Aerosol Technik Ainring GmbH & Co. KG, Ainring, Germany) measuring and counting particles in 30 minutes average | |
72 | Log-normal particle size distribution, normalized concentration at particle diameter 259.46 nm | dN/dlogDp(259.46) | #/cm3 | Lombard, Fabien | Optical particle counter ([EDM]; EDM180 GRIMM Aerosol Technik Ainring GmbH & Co. KG, Ainring, Germany) measuring and counting particles in 30 minutes average | |
73 | Log-normal particle size distribution, normalized concentration at particle diameter 268.96 nm | dN/dlogDp(268.96) | #/cm3 | Lombard, Fabien | Optical particle counter ([EDM]; EDM180 GRIMM Aerosol Technik Ainring GmbH & Co. KG, Ainring, Germany) measuring and counting particles in 30 minutes average | |
74 | Log-normal particle size distribution, normalized concentration at particle diameter 278.81 nm | dN/dlogDp(278.81) | #/cm3 | Lombard, Fabien | Optical particle counter ([EDM]; EDM180 GRIMM Aerosol Technik Ainring GmbH & Co. KG, Ainring, Germany) measuring and counting particles in 30 minutes average | |
75 | Log-normal particle size distribution, normalized concentration at particle diameter 289.03 nm | dN/dlogDp(289.03) | #/cm3 | Lombard, Fabien | Optical particle counter ([EDM]; EDM180 GRIMM Aerosol Technik Ainring GmbH & Co. KG, Ainring, Germany) measuring and counting particles in 30 minutes average | |
76 | Log-normal particle size distribution, normalized concentration at particle diameter 299.61 nm | dN/dlogDp(299.61) | #/cm3 | Lombard, Fabien | Optical particle counter ([EDM]; EDM180 GRIMM Aerosol Technik Ainring GmbH & Co. KG, Ainring, Germany) measuring and counting particles in 30 minutes average | |
77 | Log-normal particle size distribution, normalized concentration at particle diameter 310.59 nm | dN/dlogDp(310.59) | #/cm3 | Lombard, Fabien | Optical particle counter ([EDM]; EDM180 GRIMM Aerosol Technik Ainring GmbH & Co. KG, Ainring, Germany) measuring and counting particles in 30 minutes average | |
78 | Log-normal particle size distribution, normalized concentration at particle diameter 321.97 nm | dN/dlogDp(321.97) | #/cm3 | Lombard, Fabien | Optical particle counter ([EDM]; EDM180 GRIMM Aerosol Technik Ainring GmbH & Co. KG, Ainring, Germany) measuring and counting particles in 30 minutes average | |
79 | Log-normal particle size distribution, normalized concentration at particle diameter 333.76 nm | dN/dlogDp(333.76) | #/cm3 | Lombard, Fabien | Optical particle counter ([EDM]; EDM180 GRIMM Aerosol Technik Ainring GmbH & Co. KG, Ainring, Germany) measuring and counting particles in 30 minutes average | |
80 | Log-normal particle size distribution, normalized concentration at particle diameter 345.99 nm | dN/dlogDp(345.99) | #/cm3 | Lombard, Fabien | Optical particle counter ([EDM]; EDM180 GRIMM Aerosol Technik Ainring GmbH & Co. KG, Ainring, Germany) measuring and counting particles in 30 minutes average | |
81 | Log-normal particle size distribution, normalized concentration at particle diameter 358.66 nm | dN/dlogDp(358.66) | #/cm3 | Lombard, Fabien | Optical particle counter ([EDM]; EDM180 GRIMM Aerosol Technik Ainring GmbH & Co. KG, Ainring, Germany) measuring and counting particles in 30 minutes average | |
82 | Log-normal particle size distribution, normalized concentration at particle diameter 371.8 nm | dN/dlogDp(371.8) | #/cm3 | Lombard, Fabien | Optical particle counter ([EDM]; EDM180 GRIMM Aerosol Technik Ainring GmbH & Co. KG, Ainring, Germany) measuring and counting particles in 30 minutes average | |
83 | Log-normal particle size distribution, normalized concentration at particle diameter 385.42 nm | dN/dlogDp(385.42) | #/cm3 | Lombard, Fabien | Optical particle counter ([EDM]; EDM180 GRIMM Aerosol Technik Ainring GmbH & Co. KG, Ainring, Germany) measuring and counting particles in 30 minutes average | |
84 | Log-normal particle size distribution, normalized concentration at particle diameter 399.54 nm | dN/dlogDp(399.54) | #/cm3 | Lombard, Fabien | Optical particle counter ([EDM]; EDM180 GRIMM Aerosol Technik Ainring GmbH & Co. KG, Ainring, Germany) measuring and counting particles in 30 minutes average | |
85 | Log-normal particle size distribution, normalized concentration at particle diameter 414.18 nm | dN/dlogDp(414.18) | #/cm3 | Lombard, Fabien | Optical particle counter ([EDM]; EDM180 GRIMM Aerosol Technik Ainring GmbH & Co. KG, Ainring, Germany) measuring and counting particles in 30 minutes average | |
86 | Log-normal particle size distribution, normalized concentration at particle diameter 429.35 nm | dN/dlogDp(429.35) | #/cm3 | Lombard, Fabien | Optical particle counter ([EDM]; EDM180 GRIMM Aerosol Technik Ainring GmbH & Co. KG, Ainring, Germany) measuring and counting particles in 30 minutes average | |
87 | Log-normal particle size distribution, normalized concentration at particle diameter 445.08 nm | dN/dlogDp(445.08) | #/cm3 | Lombard, Fabien | Optical particle counter ([EDM]; EDM180 GRIMM Aerosol Technik Ainring GmbH & Co. KG, Ainring, Germany) measuring and counting particles in 30 minutes average | |
88 | Log-normal particle size distribution, normalized concentration at particle diameter 461.38 nm | dN/dlogDp(461.38) | #/cm3 | Lombard, Fabien | Optical particle counter ([EDM]; EDM180 GRIMM Aerosol Technik Ainring GmbH & Co. KG, Ainring, Germany) measuring and counting particles in 30 minutes average | |
89 | Log-normal particle size distribution, normalized concentration at particle diameter 478.29 nm | dN/dlogDp(478.29) | #/cm3 | Lombard, Fabien | Optical particle counter ([EDM]; EDM180 GRIMM Aerosol Technik Ainring GmbH & Co. KG, Ainring, Germany) measuring and counting particles in 30 minutes average | |
90 | Log-normal particle size distribution, normalized concentration at particle diameter 495.81 nm | dN/dlogDp(495.81) | #/cm3 | Lombard, Fabien | Optical particle counter ([EDM]; EDM180 GRIMM Aerosol Technik Ainring GmbH & Co. KG, Ainring, Germany) measuring and counting particles in 30 minutes average | |
91 | Log-normal particle size distribution, normalized concentration at particle diameter 513.97 nm | dN/dlogDp(513.97) | #/cm3 | Lombard, Fabien | Optical particle counter ([EDM]; EDM180 GRIMM Aerosol Technik Ainring GmbH & Co. KG, Ainring, Germany) measuring and counting particles in 30 minutes average | |
92 | Log-normal particle size distribution, normalized concentration at particle diameter 532.8 nm | dN/dlogDp(532.8) | #/cm3 | Lombard, Fabien | Optical particle counter ([EDM]; EDM180 GRIMM Aerosol Technik Ainring GmbH & Co. KG, Ainring, Germany) measuring and counting particles in 30 minutes average | |
93 | Log-normal particle size distribution, normalized concentration at particle diameter 552.32 nm | dN/dlogDp(552.32) | #/cm3 | Lombard, Fabien | Optical particle counter ([EDM]; EDM180 GRIMM Aerosol Technik Ainring GmbH & Co. KG, Ainring, Germany) measuring and counting particles in 30 minutes average | |
94 | Log-normal particle size distribution, normalized concentration at particle diameter 572.55 nm | dN/dlogDp(572.55) | #/cm3 | Lombard, Fabien | Optical particle counter ([EDM]; EDM180 GRIMM Aerosol Technik Ainring GmbH & Co. KG, Ainring, Germany) measuring and counting particles in 30 minutes average | |
95 | Log-normal particle size distribution, normalized concentration at particle diameter 593.52 nm | dN/dlogDp(593.52) | #/cm3 | Lombard, Fabien | Optical particle counter ([EDM]; EDM180 GRIMM Aerosol Technik Ainring GmbH & Co. KG, Ainring, Germany) measuring and counting particles in 30 minutes average | |
96 | Log-normal particle size distribution, normalized concentration at particle diameter 615.27 nm | dN/dlogDp(615.27) | #/cm3 | Lombard, Fabien | Optical particle counter ([EDM]; EDM180 GRIMM Aerosol Technik Ainring GmbH & Co. KG, Ainring, Germany) measuring and counting particles in 30 minutes average | |
97 | Log-normal particle size distribution, normalized concentration at particle diameter 637.8 nm | dN/dlogDp(637.8) | #/cm3 | Lombard, Fabien | Optical particle counter ([EDM]; EDM180 GRIMM Aerosol Technik Ainring GmbH & Co. KG, Ainring, Germany) measuring and counting particles in 30 minutes average | |
98 | Log-normal particle size distribution, normalized concentration at particle diameter 661.17 nm | dN/dlogDp(661.17) | #/cm3 | Lombard, Fabien | Optical particle counter ([EDM]; EDM180 GRIMM Aerosol Technik Ainring GmbH & Co. KG, Ainring, Germany) measuring and counting particles in 30 minutes average | |
99 | Log-normal particle size distribution, normalized concentration at particle diameter 685.39 nm | dN/dlogDp(685.39) | #/cm3 | Lombard, Fabien | Optical particle counter ([EDM]; EDM180 GRIMM Aerosol Technik Ainring GmbH & Co. KG, Ainring, Germany) measuring and counting particles in 30 minutes average | |
100 | Log-normal particle size distribution, normalized concentration at particle diameter 25.03 nm, standard deviation | dN/dlogDp(25.03) std dev | ± | Lombard, Fabien | Optical particle counter ([EDM]; EDM180 GRIMM Aerosol Technik Ainring GmbH & Co. KG, Ainring, Germany) measuring and counting particles in 30 minutes average | |
101 | Log-normal particle size distribution, normalized concentration at particle diameter 25.95 nm, standard deviation | dN/dlogDp(25.95) std dev | ± | Lombard, Fabien | Optical particle counter ([EDM]; EDM180 GRIMM Aerosol Technik Ainring GmbH & Co. KG, Ainring, Germany) measuring and counting particles in 30 minutes average | |
102 | Log-normal particle size distribution, normalized concentration at particle diameter 26.9 nm, standard deviation | dN/dlogDp(26.9) std dev | ± | Lombard, Fabien | Optical particle counter ([EDM]; EDM180 GRIMM Aerosol Technik Ainring GmbH & Co. KG, Ainring, Germany) measuring and counting particles in 30 minutes average | |
103 | Log-normal particle size distribution, normalized concentration at particle diameter 27.88 nm, standard deviation | dN/dlogDp(27.88) std dev | ± | Lombard, Fabien | Optical particle counter ([EDM]; EDM180 GRIMM Aerosol Technik Ainring GmbH & Co. KG, Ainring, Germany) measuring and counting particles in 30 minutes average | |
104 | Log-normal particle size distribution, normalized concentration at particle diameter 28.9 nm, standard deviation | dN/dlogDp(28.9) std dev | ± | Lombard, Fabien | Optical particle counter ([EDM]; EDM180 GRIMM Aerosol Technik Ainring GmbH & Co. KG, Ainring, Germany) measuring and counting particles in 30 minutes average | |
105 | Log-normal particle size distribution, normalized concentration at particle diameter 29.96 nm, standard deviation | dN/dlogDp(29.96) std dev | ± | Lombard, Fabien | Optical particle counter ([EDM]; EDM180 GRIMM Aerosol Technik Ainring GmbH & Co. KG, Ainring, Germany) measuring and counting particles in 30 minutes average | |
106 | Log-normal particle size distribution, normalized concentration at particle diameter 31.06 nm, standard deviation | dN/dlogDp(31.06) std dev | ± | Lombard, Fabien | Optical particle counter ([EDM]; EDM180 GRIMM Aerosol Technik Ainring GmbH & Co. KG, Ainring, Germany) measuring and counting particles in 30 minutes average | |
107 | Log-normal particle size distribution, normalized concentration at particle diameter 32.2 nm, standard deviation | dN/dlogDp(32.2) std dev | ± | Lombard, Fabien | Optical particle counter ([EDM]; EDM180 GRIMM Aerosol Technik Ainring GmbH & Co. KG, Ainring, Germany) measuring and counting particles in 30 minutes average | |
108 | Log-normal particle size distribution, normalized concentration at particle diameter 33.38 nm, standard deviation | dN/dlogDp(33.38) std dev | ± | Lombard, Fabien | Optical particle counter ([EDM]; EDM180 GRIMM Aerosol Technik Ainring GmbH & Co. KG, Ainring, Germany) measuring and counting particles in 30 minutes average | |
109 | Log-normal particle size distribution, normalized concentration at particle diameter 34.6 nm, standard deviation | dN/dlogDp(34.6) std dev | ± | Lombard, Fabien | Optical particle counter ([EDM]; EDM180 GRIMM Aerosol Technik Ainring GmbH & Co. KG, Ainring, Germany) measuring and counting particles in 30 minutes average | |
110 | Log-normal particle size distribution, normalized concentration at particle diameter 35.87 nm, standard deviation | dN/dlogDp(35.87) std dev | ± | Lombard, Fabien | Optical particle counter ([EDM]; EDM180 GRIMM Aerosol Technik Ainring GmbH & Co. KG, Ainring, Germany) measuring and counting particles in 30 minutes average | |
111 | Log-normal particle size distribution, normalized concentration at particle diameter 37.18 nm, standard deviation | dN/dlogDp(37.18) std dev | ± | Lombard, Fabien | Optical particle counter ([EDM]; EDM180 GRIMM Aerosol Technik Ainring GmbH & Co. KG, Ainring, Germany) measuring and counting particles in 30 minutes average | |
112 | Log-normal particle size distribution, normalized concentration at particle diameter 38.54 nm, standard deviation | dN/dlogDp(38.54) std dev | ± | Lombard, Fabien | Optical particle counter ([EDM]; EDM180 GRIMM Aerosol Technik Ainring GmbH & Co. KG, Ainring, Germany) measuring and counting particles in 30 minutes average | |
113 | Log-normal particle size distribution, normalized concentration at particle diameter 39.95 nm, standard deviation | dN/dlogDp(39.95) std dev | ± | Lombard, Fabien | Optical particle counter ([EDM]; EDM180 GRIMM Aerosol Technik Ainring GmbH & Co. KG, Ainring, Germany) measuring and counting particles in 30 minutes average | |
114 | Log-normal particle size distribution, normalized concentration at particle diameter 41.42 nm, standard deviation | dN/dlogDp(41.42) std dev | ± | Lombard, Fabien | Optical particle counter ([EDM]; EDM180 GRIMM Aerosol Technik Ainring GmbH & Co. KG, Ainring, Germany) measuring and counting particles in 30 minutes average | |
115 | Log-normal particle size distribution, normalized concentration at particle diameter 42.94 nm, standard deviation | dN/dlogDp(42.94) std dev | ± | Lombard, Fabien | Optical particle counter ([EDM]; EDM180 GRIMM Aerosol Technik Ainring GmbH & Co. KG, Ainring, Germany) measuring and counting particles in 30 minutes average | |
116 | Log-normal particle size distribution, normalized concentration at particle diameter 44.51 nm, standard deviation | dN/dlogDp(44.51) std dev | ± | Lombard, Fabien | Optical particle counter ([EDM]; EDM180 GRIMM Aerosol Technik Ainring GmbH & Co. KG, Ainring, Germany) measuring and counting particles in 30 minutes average | |
117 | Log-normal particle size distribution, normalized concentration at particle diameter 46.14 nm, standard deviation | dN/dlogDp(46.14) std dev | ± | Lombard, Fabien | Optical particle counter ([EDM]; EDM180 GRIMM Aerosol Technik Ainring GmbH & Co. KG, Ainring, Germany) measuring and counting particles in 30 minutes average | |
118 | Log-normal particle size distribution, normalized concentration at particle diameter 47.83 nm, standard deviation | dN/dlogDp(47.83) std dev | ± | Lombard, Fabien | Optical particle counter ([EDM]; EDM180 GRIMM Aerosol Technik Ainring GmbH & Co. KG, Ainring, Germany) measuring and counting particles in 30 minutes average | |
119 | Log-normal particle size distribution, normalized concentration at particle diameter 49.58 nm, standard deviation | dN/dlogDp(49.58) std dev | ± | Lombard, Fabien | Optical particle counter ([EDM]; EDM180 GRIMM Aerosol Technik Ainring GmbH & Co. KG, Ainring, Germany) measuring and counting particles in 30 minutes average | |
120 | Log-normal particle size distribution, normalized concentration at particle diameter 51.4 nm, standard deviation | dN/dlogDp(51.4) std dev | ± | Lombard, Fabien | Optical particle counter ([EDM]; EDM180 GRIMM Aerosol Technik Ainring GmbH & Co. KG, Ainring, Germany) measuring and counting particles in 30 minutes average | |
121 | Log-normal particle size distribution, normalized concentration at particle diameter 53.28 nm, standard deviation | dN/dlogDp(53.28) std dev | ± | Lombard, Fabien | Optical particle counter ([EDM]; EDM180 GRIMM Aerosol Technik Ainring GmbH & Co. KG, Ainring, Germany) measuring and counting particles in 30 minutes average | |
122 | Log-normal particle size distribution, normalized concentration at particle diameter 55.23 nm, standard deviation | dN/dlogDp(55.23) std dev | ± | Lombard, Fabien | Optical particle counter ([EDM]; EDM180 GRIMM Aerosol Technik Ainring GmbH & Co. KG, Ainring, Germany) measuring and counting particles in 30 minutes average | |
123 | Log-normal particle size distribution, normalized concentration at particle diameter 57.25 nm, standard deviation | dN/dlogDp(57.25) std dev | ± | Lombard, Fabien | Optical particle counter ([EDM]; EDM180 GRIMM Aerosol Technik Ainring GmbH & Co. KG, Ainring, Germany) measuring and counting particles in 30 minutes average | |
124 | Log-normal particle size distribution, normalized concentration at particle diameter 59.35 nm, standard deviation | dN/dlogDp(59.35) std dev | ± | Lombard, Fabien | Optical particle counter ([EDM]; EDM180 GRIMM Aerosol Technik Ainring GmbH & Co. KG, Ainring, Germany) measuring and counting particles in 30 minutes average | |
125 | Log-normal particle size distribution, normalized concentration at particle diameter 61.53 nm, standard deviation | dN/dlogDp(61.53) std dev | ± | Lombard, Fabien | Optical particle counter ([EDM]; EDM180 GRIMM Aerosol Technik Ainring GmbH & Co. KG, Ainring, Germany) measuring and counting particles in 30 minutes average | |
126 | Log-normal particle size distribution, normalized concentration at particle diameter 63.78 nm, standard deviation | dN/dlogDp(63.78) std dev | ± | Lombard, Fabien | Optical particle counter ([EDM]; EDM180 GRIMM Aerosol Technik Ainring GmbH & Co. KG, Ainring, Germany) measuring and counting particles in 30 minutes average | |
127 | Log-normal particle size distribution, normalized concentration at particle diameter 66.12 nm, standard deviation | dN/dlogDp(66.12) std dev | ± | Lombard, Fabien | Optical particle counter ([EDM]; EDM180 GRIMM Aerosol Technik Ainring GmbH & Co. KG, Ainring, Germany) measuring and counting particles in 30 minutes average | |
128 | Log-normal particle size distribution, normalized concentration at particle diameter 68.54 nm, standard deviation | dN/dlogDp(68.54) std dev | ± | Lombard, Fabien | Optical particle counter ([EDM]; EDM180 GRIMM Aerosol Technik Ainring GmbH & Co. KG, Ainring, Germany) measuring and counting particles in 30 minutes average | |
129 | Log-normal particle size distribution, normalized concentration at particle diameter 71.05 nm, standard deviation | dN/dlogDp(71.05) std dev | ± | Lombard, Fabien | Optical particle counter ([EDM]; EDM180 GRIMM Aerosol Technik Ainring GmbH & Co. KG, Ainring, Germany) measuring and counting particles in 30 minutes average | |
130 | Log-normal particle size distribution, normalized concentration at particle diameter 73.65 nm, standard deviation | dN/dlogDp(73.65) std dev | ± | Lombard, Fabien | Optical particle counter ([EDM]; EDM180 GRIMM Aerosol Technik Ainring GmbH & Co. KG, Ainring, Germany) measuring and counting particles in 30 minutes average | |
131 | Log-normal particle size distribution, normalized concentration at particle diameter 76.35 nm, standard deviation | dN/dlogDp(76.35) std dev | ± | Lombard, Fabien | Optical particle counter ([EDM]; EDM180 GRIMM Aerosol Technik Ainring GmbH & Co. KG, Ainring, Germany) measuring and counting particles in 30 minutes average | |
132 | Log-normal particle size distribution, normalized concentration at particle diameter 79.15 nm, standard deviation | dN/dlogDp(79.15) std dev | ± | Lombard, Fabien | Optical particle counter ([EDM]; EDM180 GRIMM Aerosol Technik Ainring GmbH & Co. KG, Ainring, Germany) measuring and counting particles in 30 minutes average | |
133 | Log-normal particle size distribution, normalized concentration at particle diameter 82.05 nm, standard deviation | dN/dlogDp(82.05) std dev | ± | Lombard, Fabien | Optical particle counter ([EDM]; EDM180 GRIMM Aerosol Technik Ainring GmbH & Co. KG, Ainring, Germany) measuring and counting particles in 30 minutes average | |
134 | Log-normal particle size distribution, normalized concentration at particle diameter 85.05 nm, standard deviation | dN/dlogDp(85.05) std dev | ± | Lombard, Fabien | Optical particle counter ([EDM]; EDM180 GRIMM Aerosol Technik Ainring GmbH & Co. KG, Ainring, Germany) measuring and counting particles in 30 minutes average | |
135 | Log-normal particle size distribution, normalized concentration at particle diameter 88.17 nm, standard deviation | dN/dlogDp(88.17) std dev | ± | Lombard, Fabien | Optical particle counter ([EDM]; EDM180 GRIMM Aerosol Technik Ainring GmbH & Co. KG, Ainring, Germany) measuring and counting particles in 30 minutes average | |
136 | Log-normal particle size distribution, normalized concentration at particle diameter 91.4 nm, standard deviation | dN/dlogDp(91.4) std dev | ± | Lombard, Fabien | Optical particle counter ([EDM]; EDM180 GRIMM Aerosol Technik Ainring GmbH & Co. KG, Ainring, Germany) measuring and counting particles in 30 minutes average | |
137 | Log-normal particle size distribution, normalized concentration at particle diameter 94.75 nm, standard deviation | dN/dlogDp(94.75) std dev | ± | Lombard, Fabien | Optical particle counter ([EDM]; EDM180 GRIMM Aerosol Technik Ainring GmbH & Co. KG, Ainring, Germany) measuring and counting particles in 30 minutes average | |
138 | Log-normal particle size distribution, normalized concentration at particle diameter 98.22 nm, standard deviation | dN/dlogDp(98.22) std dev | ± | Lombard, Fabien | Optical particle counter ([EDM]; EDM180 GRIMM Aerosol Technik Ainring GmbH & Co. KG, Ainring, Germany) measuring and counting particles in 30 minutes average | |
139 | Log-normal particle size distribution, normalized concentration at particle diameter 101.82 nm, standard deviation | dN/dlogDp(101.82) std dev | ± | Lombard, Fabien | Optical particle counter ([EDM]; EDM180 GRIMM Aerosol Technik Ainring GmbH & Co. KG, Ainring, Germany) measuring and counting particles in 30 minutes average | |
140 | Log-normal particle size distribution, normalized concentration at particle diameter 105.54 nm, standard deviation | dN/dlogDp(105.54) std dev | ± | Lombard, Fabien | Optical particle counter ([EDM]; EDM180 GRIMM Aerosol Technik Ainring GmbH & Co. KG, Ainring, Germany) measuring and counting particles in 30 minutes average | |
141 | Log-normal particle size distribution, normalized concentration at particle diameter 109.41 nm, standard deviation | dN/dlogDp(109.41) std dev | ± | Lombard, Fabien | Optical particle counter ([EDM]; EDM180 GRIMM Aerosol Technik Ainring GmbH & Co. KG, Ainring, Germany) measuring and counting particles in 30 minutes average | |
142 | Log-normal particle size distribution, normalized concentration at particle diameter 113.42 nm, standard deviation | dN/dlogDp(113.42) std dev | ± | Lombard, Fabien | Optical particle counter ([EDM]; EDM180 GRIMM Aerosol Technik Ainring GmbH & Co. KG, Ainring, Germany) measuring and counting particles in 30 minutes average | |
143 | Log-normal particle size distribution, normalized concentration at particle diameter 117.57 nm, standard deviation | dN/dlogDp(117.57) std dev | ± | Lombard, Fabien | Optical particle counter ([EDM]; EDM180 GRIMM Aerosol Technik Ainring GmbH & Co. KG, Ainring, Germany) measuring and counting particles in 30 minutes average | |
144 | Log-normal particle size distribution, normalized concentration at particle diameter 121.88 nm, standard deviation | dN/dlogDp(121.88) std dev | ± | Lombard, Fabien | Optical particle counter ([EDM]; EDM180 GRIMM Aerosol Technik Ainring GmbH & Co. KG, Ainring, Germany) measuring and counting particles in 30 minutes average | |
145 | Log-normal particle size distribution, normalized concentration at particle diameter 126.35 nm, standard deviation | dN/dlogDp(126.35) std dev | ± | Lombard, Fabien | Optical particle counter ([EDM]; EDM180 GRIMM Aerosol Technik Ainring GmbH & Co. KG, Ainring, Germany) measuring and counting particles in 30 minutes average | |
146 | Log-normal particle size distribution, normalized concentration at particle diameter 130.97 nm, standard deviation | dN/dlogDp(130.97) std dev | ± | Lombard, Fabien | Optical particle counter ([EDM]; EDM180 GRIMM Aerosol Technik Ainring GmbH & Co. KG, Ainring, Germany) measuring and counting particles in 30 minutes average | |
147 | Log-normal particle size distribution, normalized concentration at particle diameter 135.77 nm, standard deviation | dN/dlogDp(135.77) std dev | ± | Lombard, Fabien | Optical particle counter ([EDM]; EDM180 GRIMM Aerosol Technik Ainring GmbH & Co. KG, Ainring, Germany) measuring and counting particles in 30 minutes average | |
148 | Log-normal particle size distribution, normalized concentration at particle diameter 140.75 nm, standard deviation | dN/dlogDp(140.75) std dev | ± | Lombard, Fabien | Optical particle counter ([EDM]; EDM180 GRIMM Aerosol Technik Ainring GmbH & Co. KG, Ainring, Germany) measuring and counting particles in 30 minutes average | |
149 | Log-normal particle size distribution, normalized concentration at particle diameter 145.9 nm, standard deviation | dN/dlogDp(145.9) std dev | ± | Lombard, Fabien | Optical particle counter ([EDM]; EDM180 GRIMM Aerosol Technik Ainring GmbH & Co. KG, Ainring, Germany) measuring and counting particles in 30 minutes average | |
150 | Log-normal particle size distribution, normalized concentration at particle diameter 151.25 nm, standard deviation | dN/dlogDp(151.25) std dev | ± | Lombard, Fabien | Optical particle counter ([EDM]; EDM180 GRIMM Aerosol Technik Ainring GmbH & Co. KG, Ainring, Germany) measuring and counting particles in 30 minutes average | |
151 | Log-normal particle size distribution, normalized concentration at particle diameter 156.79 nm, standard deviation | dN/dlogDp(156.79) std dev | ± | Lombard, Fabien | Optical particle counter ([EDM]; EDM180 GRIMM Aerosol Technik Ainring GmbH & Co. KG, Ainring, Germany) measuring and counting particles in 30 minutes average | |
152 | Log-normal particle size distribution, normalized concentration at particle diameter 162.53 nm, standard deviation | dN/dlogDp(162.53) std dev | ± | Lombard, Fabien | Optical particle counter ([EDM]; EDM180 GRIMM Aerosol Technik Ainring GmbH & Co. KG, Ainring, Germany) measuring and counting particles in 30 minutes average | |
153 | Log-normal particle size distribution, normalized concentration at particle diameter 168.49 nm, standard deviation | dN/dlogDp(168.49) std dev | ± | Lombard, Fabien | Optical particle counter ([EDM]; EDM180 GRIMM Aerosol Technik Ainring GmbH & Co. KG, Ainring, Germany) measuring and counting particles in 30 minutes average | |
154 | Log-normal particle size distribution, normalized concentration at particle diameter 174.66 nm, standard deviation | dN/dlogDp(174.66) std dev | ± | Lombard, Fabien | Optical particle counter ([EDM]; EDM180 GRIMM Aerosol Technik Ainring GmbH & Co. KG, Ainring, Germany) measuring and counting particles in 30 minutes average | |
155 | Log-normal particle size distribution, normalized concentration at particle diameter 181.06 nm, standard deviation | dN/dlogDp(181.06) std dev | ± | Lombard, Fabien | Optical particle counter ([EDM]; EDM180 GRIMM Aerosol Technik Ainring GmbH & Co. KG, Ainring, Germany) measuring and counting particles in 30 minutes average | |
156 | Log-normal particle size distribution, normalized concentration at particle diameter 187.69 nm, standard deviation | dN/dlogDp(187.69) std dev | ± | Lombard, Fabien | Optical particle counter ([EDM]; EDM180 GRIMM Aerosol Technik Ainring GmbH & Co. KG, Ainring, Germany) measuring and counting particles in 30 minutes average | |
157 | Log-normal particle size distribution, normalized concentration at particle diameter 194.56 nm, standard deviation | dN/dlogDp(194.56) std dev | ± | Lombard, Fabien | Optical particle counter ([EDM]; EDM180 GRIMM Aerosol Technik Ainring GmbH & Co. KG, Ainring, Germany) measuring and counting particles in 30 minutes average | |
158 | Log-normal particle size distribution, normalized concentration at particle diameter 201.69 nm, standard deviation | dN/dlogDp(201.69) std dev | ± | Lombard, Fabien | Optical particle counter ([EDM]; EDM180 GRIMM Aerosol Technik Ainring GmbH & Co. KG, Ainring, Germany) measuring and counting particles in 30 minutes average | |
159 | Log-normal particle size distribution, normalized concentration at particle diameter 209.08 nm, standard deviation | dN/dlogDp(209.08) std dev | ± | Lombard, Fabien | Optical particle counter ([EDM]; EDM180 GRIMM Aerosol Technik Ainring GmbH & Co. KG, Ainring, Germany) measuring and counting particles in 30 minutes average | |
160 | Log-normal particle size distribution, normalized concentration at particle diameter 216.74 nm, standard deviation | dN/dlogDp(216.74) std dev | ± | Lombard, Fabien | Optical particle counter ([EDM]; EDM180 GRIMM Aerosol Technik Ainring GmbH & Co. KG, Ainring, Germany) measuring and counting particles in 30 minutes average | |
161 | Log-normal particle size distribution, normalized concentration at particle diameter 224.68 nm, standard deviation | dN/dlogDp(224.68) std dev | ± | Lombard, Fabien | Optical particle counter ([EDM]; EDM180 GRIMM Aerosol Technik Ainring GmbH & Co. KG, Ainring, Germany) measuring and counting particles in 30 minutes average | |
162 | Log-normal particle size distribution, normalized concentration at particle diameter 232.91 nm, standard deviation | dN/dlogDp(232.91) std dev | ± | Lombard, Fabien | Optical particle counter ([EDM]; EDM180 GRIMM Aerosol Technik Ainring GmbH & Co. KG, Ainring, Germany) measuring and counting particles in 30 minutes average | |
163 | Log-normal particle size distribution, normalized concentration at particle diameter 241.44 nm, standard deviation | dN/dlogDp(241.44) std dev | ± | Lombard, Fabien | Optical particle counter ([EDM]; EDM180 GRIMM Aerosol Technik Ainring GmbH & Co. KG, Ainring, Germany) measuring and counting particles in 30 minutes average | |
164 | Log-normal particle size distribution, normalized concentration at particle diameter 250.29 nm, standard deviation | dN/dlogDp(250.29) std dev | ± | Lombard, Fabien | Optical particle counter ([EDM]; EDM180 GRIMM Aerosol Technik Ainring GmbH & Co. KG, Ainring, Germany) measuring and counting particles in 30 minutes average | |
165 | Log-normal particle size distribution, normalized concentration at particle diameter 259.46 nm, standard deviation | dN/dlogDp(259.46) std dev | ± | Lombard, Fabien | Optical particle counter ([EDM]; EDM180 GRIMM Aerosol Technik Ainring GmbH & Co. KG, Ainring, Germany) measuring and counting particles in 30 minutes average | |
166 | Log-normal particle size distribution, normalized concentration at particle diameter 268.96 nm, standard deviation | dN/dlogDp(268.96) std dev | ± | Lombard, Fabien | Optical particle counter ([EDM]; EDM180 GRIMM Aerosol Technik Ainring GmbH & Co. KG, Ainring, Germany) measuring and counting particles in 30 minutes average | |
167 | Log-normal particle size distribution, normalized concentration at particle diameter 278.81 nm, standard deviation | dN/dlogDp(278.81) std dev | ± | Lombard, Fabien | Optical particle counter ([EDM]; EDM180 GRIMM Aerosol Technik Ainring GmbH & Co. KG, Ainring, Germany) measuring and counting particles in 30 minutes average | |
168 | Log-normal particle size distribution, normalized concentration at particle diameter 289.03 nm, standard deviation | dN/dlogDp(289.03) std dev | ± | Lombard, Fabien | Optical particle counter ([EDM]; EDM180 GRIMM Aerosol Technik Ainring GmbH & Co. KG, Ainring, Germany) measuring and counting particles in 30 minutes average | |
169 | Log-normal particle size distribution, normalized concentration at particle diameter 299.61 nm, standard deviation | dN/dlogDp(299.61) std dev | ± | Lombard, Fabien | Optical particle counter ([EDM]; EDM180 GRIMM Aerosol Technik Ainring GmbH & Co. KG, Ainring, Germany) measuring and counting particles in 30 minutes average | |
170 | Log-normal particle size distribution, normalized concentration at particle diameter 310.59 nm, standard deviation | dN/dlogDp(310.59) std dev | ± | Lombard, Fabien | Optical particle counter ([EDM]; EDM180 GRIMM Aerosol Technik Ainring GmbH & Co. KG, Ainring, Germany) measuring and counting particles in 30 minutes average | |
171 | Log-normal particle size distribution, normalized concentration at particle diameter 321.97 nm, standard deviation | dN/dlogDp(321.97) std dev | ± | Lombard, Fabien | Optical particle counter ([EDM]; EDM180 GRIMM Aerosol Technik Ainring GmbH & Co. KG, Ainring, Germany) measuring and counting particles in 30 minutes average | |
172 | Log-normal particle size distribution, normalized concentration at particle diameter 333.76 nm, standard deviation | dN/dlogDp(333.76) std dev | ± | Lombard, Fabien | Optical particle counter ([EDM]; EDM180 GRIMM Aerosol Technik Ainring GmbH & Co. KG, Ainring, Germany) measuring and counting particles in 30 minutes average | |
173 | Log-normal particle size distribution, normalized concentration at particle diameter 345.99 nm, standard deviation | dN/dlogDp(345.99) std dev | ± | Lombard, Fabien | Optical particle counter ([EDM]; EDM180 GRIMM Aerosol Technik Ainring GmbH & Co. KG, Ainring, Germany) measuring and counting particles in 30 minutes average | |
174 | Log-normal particle size distribution, normalized concentration at particle diameter 358.66 nm, standard deviation | dN/dlogDp(358.66) std dev | ± | Lombard, Fabien | Optical particle counter ([EDM]; EDM180 GRIMM Aerosol Technik Ainring GmbH & Co. KG, Ainring, Germany) measuring and counting particles in 30 minutes average | |
175 | Log-normal particle size distribution, normalized concentration at particle diameter 371.8 nm, standard deviation | dN/dlogDp(371.8) std dev | ± | Lombard, Fabien | Optical particle counter ([EDM]; EDM180 GRIMM Aerosol Technik Ainring GmbH & Co. KG, Ainring, Germany) measuring and counting particles in 30 minutes average | |
176 | Log-normal particle size distribution, normalized concentration at particle diameter 385.42 nm, standard deviation | dN/dlogDp(385.42) std dev | ± | Lombard, Fabien | Optical particle counter ([EDM]; EDM180 GRIMM Aerosol Technik Ainring GmbH & Co. KG, Ainring, Germany) measuring and counting particles in 30 minutes average | |
177 | Log-normal particle size distribution, normalized concentration at particle diameter 399.54 nm, standard deviation | dN/dlogDp(399.54) std dev | ± | Lombard, Fabien | Optical particle counter ([EDM]; EDM180 GRIMM Aerosol Technik Ainring GmbH & Co. KG, Ainring, Germany) measuring and counting particles in 30 minutes average | |
178 | Log-normal particle size distribution, normalized concentration at particle diameter 414.18 nm, standard deviation | dN/dlogDp(414.18) std dev | ± | Lombard, Fabien | Optical particle counter ([EDM]; EDM180 GRIMM Aerosol Technik Ainring GmbH & Co. KG, Ainring, Germany) measuring and counting particles in 30 minutes average | |
179 | Log-normal particle size distribution, normalized concentration at particle diameter 429.35 nm, standard deviation | dN/dlogDp(429.35) std dev | ± | Lombard, Fabien | Optical particle counter ([EDM]; EDM180 GRIMM Aerosol Technik Ainring GmbH & Co. KG, Ainring, Germany) measuring and counting particles in 30 minutes average | |
180 | Log-normal particle size distribution, normalized concentration at particle diameter 445.08 nm, standard deviation | dN/dlogDp(445.08) std dev | ± | Lombard, Fabien | Optical particle counter ([EDM]; EDM180 GRIMM Aerosol Technik Ainring GmbH & Co. KG, Ainring, Germany) measuring and counting particles in 30 minutes average | |
181 | Log-normal particle size distribution, normalized concentration at particle diameter 461.38 nm, standard deviation | dN/dlogDp(461.38) std dev | ± | Lombard, Fabien | Optical particle counter ([EDM]; EDM180 GRIMM Aerosol Technik Ainring GmbH & Co. KG, Ainring, Germany) measuring and counting particles in 30 minutes average | |
182 | Log-normal particle size distribution, normalized concentration at particle diameter 478.29 nm, standard deviation | dN/dlogDp(478.29) std dev | ± | Lombard, Fabien | Optical particle counter ([EDM]; EDM180 GRIMM Aerosol Technik Ainring GmbH & Co. KG, Ainring, Germany) measuring and counting particles in 30 minutes average | |
183 | Log-normal particle size distribution, normalized concentration at particle diameter 495.81 nm, standard deviation | dN/dlogDp(495.81) std dev | ± | Lombard, Fabien | Optical particle counter ([EDM]; EDM180 GRIMM Aerosol Technik Ainring GmbH & Co. KG, Ainring, Germany) measuring and counting particles in 30 minutes average | |
184 | Log-normal particle size distribution, normalized concentration at particle diameter 513.97 nm, standard deviation | dN/dlogDp(513.97) std dev | ± | Lombard, Fabien | Optical particle counter ([EDM]; EDM180 GRIMM Aerosol Technik Ainring GmbH & Co. KG, Ainring, Germany) measuring and counting particles in 30 minutes average | |
185 | Log-normal particle size distribution, normalized concentration at particle diameter 532.8 nm, standard deviation | dN/dlogDp(532.8) std dev | ± | Lombard, Fabien | Optical particle counter ([EDM]; EDM180 GRIMM Aerosol Technik Ainring GmbH & Co. KG, Ainring, Germany) measuring and counting particles in 30 minutes average | |
186 | Log-normal particle size distribution, normalized concentration at particle diameter 552.32 nm, standard deviation | dN/dlogDp(552.32) std dev | ± | Lombard, Fabien | Optical particle counter ([EDM]; EDM180 GRIMM Aerosol Technik Ainring GmbH & Co. KG, Ainring, Germany) measuring and counting particles in 30 minutes average | |
187 | Log-normal particle size distribution, normalized concentration at particle diameter 572.55 nm, standard deviation | dN/dlogDp(572.55) std dev | ± | Lombard, Fabien | Optical particle counter ([EDM]; EDM180 GRIMM Aerosol Technik Ainring GmbH & Co. KG, Ainring, Germany) measuring and counting particles in 30 minutes average | |
188 | Log-normal particle size distribution, normalized concentration at particle diameter 593.52 nm, standard deviation | dN/dlogDp(593.52) std dev | ± | Lombard, Fabien | Optical particle counter ([EDM]; EDM180 GRIMM Aerosol Technik Ainring GmbH & Co. KG, Ainring, Germany) measuring and counting particles in 30 minutes average | |
189 | Log-normal particle size distribution, normalized concentration at particle diameter 615.27 nm, standard deviation | dN/dlogDp(615.27) std dev | ± | Lombard, Fabien | Optical particle counter ([EDM]; EDM180 GRIMM Aerosol Technik Ainring GmbH & Co. KG, Ainring, Germany) measuring and counting particles in 30 minutes average | |
190 | Log-normal particle size distribution, normalized concentration at particle diameter 637.8 nm, standard deviation | dN/dlogDp(637.8) std dev | ± | Lombard, Fabien | Optical particle counter ([EDM]; EDM180 GRIMM Aerosol Technik Ainring GmbH & Co. KG, Ainring, Germany) measuring and counting particles in 30 minutes average | |
191 | Log-normal particle size distribution, normalized concentration at particle diameter 661.17 nm, standard deviation | dN/dlogDp(661.17) std dev | ± | Lombard, Fabien | Optical particle counter ([EDM]; EDM180 GRIMM Aerosol Technik Ainring GmbH & Co. KG, Ainring, Germany) measuring and counting particles in 30 minutes average | |
192 | Log-normal particle size distribution, normalized concentration at particle diameter 685.39 nm, standard deviation | dN/dlogDp(685.39) std dev | ± | Lombard, Fabien | Optical particle counter ([EDM]; EDM180 GRIMM Aerosol Technik Ainring GmbH & Co. KG, Ainring, Germany) measuring and counting particles in 30 minutes average |
License:
Creative Commons Attribution 4.0 International (CC-BY-4.0)
Status:
Curation Level: Enhanced curation (CurationLevelC)
Size:
2410457 data points
Download Data
View dataset as HTML (shows only first 2000 rows)