電気学会論文誌C(電子・情報・システム部門誌)
Online ISSN : 1348-8155
Print ISSN : 0385-4221
ISSN-L : 0385-4221
拡張型動脈系電気回路モデルを用いた漢方内服時における橈骨動脈圧波形変化の検討
石山 仁笠原 宏天野 和彦上馬場 和夫許 鳳浩
著者情報
ジャーナル フリー

2002 年 122 巻 7 号 p. 1110-1119

詳細
抄録

An internal-use medication experiment of Ninjin-to and Mao-to was performed to six healthy adult males. The radial artery pressure pulse and stroke volume before and after taking each medicines were measured for 2 hours at every of 30 minutes. Then circuit constant of the five-element electric circuit arterial model which authors reported previously was calculated from the measured radial artery pressure pulse and stroke volume. Comparison examinations were carried out among each individual on the change of the calculated circuit constant with the passage of time. As the results, the change of the radial artery pressure pulse due to the internal-use of Ninjin-to and Mao-to has been able to be shown quantitatively as change of the central and peripheral constants.

著者関連情報
© 電気学会
前の記事 次の記事
feedback
Top