Skip to content
Licensed Unlicensed Requires Authentication Published by De Gruyter January 23, 2024

Pull-out strength of screws in long bones at different insertion angles: finite element analysis and experimental investigations

  • Osman İyibilgin

    Osman İyibilgin received his Bachelor Graduation from Hacettepe University in 1995. He received a master’s degree from Bülent Ecevit University in 1998. He gets a doctorate degree from Sakarya University in 2004. He carried out postdoctoral research activities in the USA (Missouri University of Science and Technology, Rolla) from 2012 to 2014. Since 2008, he has been working as a faculty member and Assistant Professor in the Department of Mechanical Engineering at Sakarya University. His main research interests are finite element methods, biomechanics, biomaterials, and additive manufacturing.

    ORCID logo EMAIL logo
    , Engin Gepek

    Engin Gepek, born in 1988, studied Physics at Izmir Institute of Technology. He is an PHD student at Sakarya University. His research interests include the finite element method, biomechanics, biomaterials, and additive manufacturing.

    ORCID logo
    , Levent Bayam

    Levent Bayam is an orthopedic surgeon and associate professor at Medipol University, Istanbul, with a special interest in arthroscopy, lower arthroplasty, and biomechanic, biomedical engineering. He has completed 3 master’s degrees in the UK, a lower limb arthroplasty fellowship at Montreal University, Canada with visiting fellowship program by EFORT, and recently a one-year orthopedic oncology diploma, BOOS. He currently teaches at the biomedical engineering department and international medical school at Medipol University and is actively involved in research with many publications and presentations.

    ORCID logo
    , Efstathios Drampalos

    Efstathios Drampalos is a consultant at Forth Valley NHS Hospital, UK. He graduated from the University of Bologna, Italy in 2002 and completed his training in orthopedic surgery in Greece. He also completed two fellowships in Foot and Ankle Surgery at Wrightington and Wythenshawe hospitals. Since 2013, he has been working in the UK. He has many publications in peer review journals, 2 books, and many presentations in congresses. He teaches medical students at the University of Glasgow and he is a Senior clinical lecturer. His research interests include foot and ankle surgeries and biomechanical studies.

    ORCID logo
    and Amer Shoaib

    Amer Shoaib is a consultant orthopedic surgeon at Manchester University Hospital NHS Foundation Trust, UK, specializing in surgery and conditions of the foot and ankle. His practice centers around foot and ankle surgery from bunions to ankle arthritis. He uses keyhole surgery for bunions, ankle pain, and Achilles tendon injuries. He also deals with complicated limb injuries and deformities with circular frame external fixators. He teaches courses run by the British Orthopedic Foot and Ankle Society and gives lectures for the British Limb Reconstruction Society. He has also worked in several war zones for charities to treat casualties.

From the journal Materials Testing

Abstract

Different types of plates are available to allow insertion of screws for internal fixation of long bone fractures. The aim of the study was to determine the effect of the insertion of screws at different angles on a long bone to the pull-out strength. Using 3D printed bone models, we tested the pull-out strength of screws in long bones at insertion angles between 0 and 40° with both finite element analysis and on printed models experimentally and compared the results. Test samples and cortical screws used were modeled with SolidWorks software and analyzed with Ansys software. As the screw insertion angle increases, the pull-out forces on the test specimens increase from 61.14 ± 3.5 N at 0° to 273 ± 6.8 N at 40° with an exception of a small drop between 15 and 20° from 235.4 ± 6.2 to 233 ± 6.9 N. Both methods showed an increase in the pull-out strength of screws as the insertion angle increases. This might be applicable in the clinical practice of bone fixation. Further studies on plate and screw fixation are needed to complement the findings.


Corresponding author: Osman İyibilgin, Department of Mechanical Engineering, Sakarya University, Sakarya, Türkiye, E-mail:

Funding source: Scientific Research Projects Commission of Sakarya University

Award Identifier / Grant number: 2022-7-25-86

About the authors

Osman İyibilgin

Osman İyibilgin received his Bachelor Graduation from Hacettepe University in 1995. He received a master’s degree from Bülent Ecevit University in 1998. He gets a doctorate degree from Sakarya University in 2004. He carried out postdoctoral research activities in the USA (Missouri University of Science and Technology, Rolla) from 2012 to 2014. Since 2008, he has been working as a faculty member and Assistant Professor in the Department of Mechanical Engineering at Sakarya University. His main research interests are finite element methods, biomechanics, biomaterials, and additive manufacturing.

Engin Gepek

Engin Gepek, born in 1988, studied Physics at Izmir Institute of Technology. He is an PHD student at Sakarya University. His research interests include the finite element method, biomechanics, biomaterials, and additive manufacturing.

Levent Bayam

Levent Bayam is an orthopedic surgeon and associate professor at Medipol University, Istanbul, with a special interest in arthroscopy, lower arthroplasty, and biomechanic, biomedical engineering. He has completed 3 master’s degrees in the UK, a lower limb arthroplasty fellowship at Montreal University, Canada with visiting fellowship program by EFORT, and recently a one-year orthopedic oncology diploma, BOOS. He currently teaches at the biomedical engineering department and international medical school at Medipol University and is actively involved in research with many publications and presentations.

Efstathios Drampalos

Efstathios Drampalos is a consultant at Forth Valley NHS Hospital, UK. He graduated from the University of Bologna, Italy in 2002 and completed his training in orthopedic surgery in Greece. He also completed two fellowships in Foot and Ankle Surgery at Wrightington and Wythenshawe hospitals. Since 2013, he has been working in the UK. He has many publications in peer review journals, 2 books, and many presentations in congresses. He teaches medical students at the University of Glasgow and he is a Senior clinical lecturer. His research interests include foot and ankle surgeries and biomechanical studies.

Amer Shoaib

Amer Shoaib is a consultant orthopedic surgeon at Manchester University Hospital NHS Foundation Trust, UK, specializing in surgery and conditions of the foot and ankle. His practice centers around foot and ankle surgery from bunions to ankle arthritis. He uses keyhole surgery for bunions, ankle pain, and Achilles tendon injuries. He also deals with complicated limb injuries and deformities with circular frame external fixators. He teaches courses run by the British Orthopedic Foot and Ankle Society and gives lectures for the British Limb Reconstruction Society. He has also worked in several war zones for charities to treat casualties.

  1. Research ethics: Not applicable.

  2. Author contributions: Osman İYİBİLGİN: Finite element analysis and manuscript writing preparation; Engin GEPEK: Finite element analysis and experiments; Levent BAYAM: study planning and Manuscript writing preparation; Efstathios Drampalos: Writing the article and making corrections and comments; Amer Shoaib: Writing the article and making corrections and comments.

  3. Competing interests: The authors state no conflict of interest.

  4. Research funding: Scientific Research Projects Commission of Sakarya University (Project number: 2022-7-25-86).

  5. Data availability: The raw data can be obtained on request from the corresponding author.

References

[1] Y. Cao, Y. Zhang, L. Huang, and X. Huang, “The impact of plate length, fibula integrity and plate placement on tibial shaft fixation stability: a finite element study,” J. Orthop. Surg. Res., vol. 14, no. 1, pp. 1–7, 2019, https://doi.org/10.1186/s13018-019-1088-y.Search in Google Scholar PubMed PubMed Central

[2] H. S. Hedia and I. M. R. Najjar, “Bio-medical materials in human joint implants – a review,” Mater. Test., vol. 53, no. 5, pp. 266–279, 2011. https://doi.org/10.3139/120.110223.Search in Google Scholar

[3] T. T. Eckel, R. R. Glisson, P. Anand, and S. G. Parekh, “Biomechanical comparison of 4 different lateral plate constructs for distal fibula fractures,” Foot Ankle Int., vol. 34, no. 11, pp. 1588–1595, 2013, https://doi.org/10.1177/1071100713496223.Search in Google Scholar PubMed

[4] C. L. Graw, et al.., “A new manufacturing process for allogeneic bone plates based on high hydrostatic pressure-treated granules for jaw augmentation,” Materialpruefung/Mater. Test., vol. 65, no. 8, pp. 1155–1166, 2023. https://doi.org/10.1515/mt-2023-0004.Search in Google Scholar

[5] C. Halbauer, F. Capanni, I. Bertusch, A. Paech, T. Merkle, and T. Da Silva, “Biomechanical testing of osteosynthetic locking plates for proximal humeral shaft fractures – a systematic literature review,” Biomed. Tech. Biomed. Eng., vol. 68, no. 6, pp. 553–561, 2023. https://doi.org/10.1515/bmt-2023-0039.Search in Google Scholar PubMed

[6] D. Jiang, S. Zhan, Q. Wang, M. Ling, H. Hu, and W. Jia, “Biomechanical comparison of locking plate and cancellous screw techniques in medial malleolar fractures: a finite element analysis,” J. Foot Ankle Surg., vol. 58, no. 6, pp. 1138–1144, 2019, https://doi.org/10.1053/j.jfas.2018.10.005.Search in Google Scholar PubMed

[7] S. Aktas and Y. Kisioglu, “Improving the fatigue life of produced dental implants by the thread-rolling process,” Mater. Test., vol. 64, no. 7, pp. 1012–1025, 2022. https://doi.org/10.1515/mt-2021-2159.Search in Google Scholar

[8] R. P. Singh, V. Gupta, P. M. Pandey, and A. R. Mridha, “Effect of drilling techniques on microcracks and pull-out strength of cortical screw fixed in human tibia: an in-vitro study,” Ann. Biomed. Eng., vol. 49, no. 1, pp. 382–393, 2021, https://doi.org/10.1007/s10439-020-02565-2.Search in Google Scholar PubMed

[9] P. S. D. Patel, D. W. L. Hukins, and D. E. T. Shepherd, “The effect of “toggling” on the pullout strength of bone screws in normal and osteoporotic bone models,” Open Mech. Eng. J., vol. 7, no. 1, pp. 35–39, 2013, https://doi.org/10.2174/1874155X01307010035.Search in Google Scholar

[10] J. B. Selby, D. L. Johnson, P. Hester, and D. N. M. Caborn, “Effect of screw length on bioabsorbable interference screw fixation in a tibial bone tunnel,” Am. J. Sports Med., vol. 29, no. 5, pp. 614–619, 2001, https://doi.org/10.1177/03635465010290051401.Search in Google Scholar PubMed

[11] J. Nie, et al., “The fixation effect of different types of screws in the whole osteoporotic lumbar vertebrae: an FEA study,” J. Mech. Med. Biol., vol. 22, no. 10, supp. 2250034, pp. 1–14, 2022. https://doi.org/10.1142/S0219519422500348.Search in Google Scholar

[12] Q. H. Zhang, S. H. Tan, and S. M. Chou, “Effects of bone materials on the screw pull-out strength in human spine,” Med. Eng. Phys., vol. 28, no. 8, pp. 795–801, 2006, https://doi.org/10.1016/j.medengphy.2005.11.009.Search in Google Scholar PubMed

[13] A. Anwar, et al.., “Finite element analysis of the three different posterior malleolus fixation strategies in relation to different fracture sizes,” Injury, vol. 48, no. 4, pp. 825–832, 2017, https://doi.org/10.1016/j.injury.2017.02.012.Search in Google Scholar PubMed

[14] N. J. White, D. T. Corr, J. P. Wagg, C. Lorincz, and R. E. Buckley, “Locked plate fixation of the comminuted distal fibula: a biomechanical study,” Can. J. Surg., vol. 56, no. 1, pp. 35–40, 2013, https://doi.org/10.1503/cjs.012311.Search in Google Scholar PubMed PubMed Central

[15] H. Ketata, F. Affes, M. Kharrat, and M. Dammak, “A comparative study of tapped and untapped pilot holes for bicortical orthopedic screws – 3D finite element analysis with an experimental test,” Biomed. Tech., vol. 64, no. 5, pp. 563–570, 2019, https://doi.org/10.1515/bmt-2018-0049.Search in Google Scholar PubMed

[16] P. S. D. Patel, D. E. T. Shepherd, and D. W. L. Hukins, “The effect of screw insertion angle and thread type on the pullout strength of bone screws in normal and osteoporotic cancellous bone models,” Med. Eng. Phys., vol. 32, no. 8, pp. 822–828, 2010, https://doi.org/10.1016/j.medengphy.2010.05.005.Search in Google Scholar PubMed

[17] K. Wermelin, P. Aspenberg, P. Linderbäck, and P. Tengvall, “Bisphosphonate coating on titanium screws increases mechanical fixation in rat tibia after two weeks,” J. Biomed. Mater. Res. A, vol. 86, no. 1, pp. 220–227, 2008, https://doi.org/10.1002/jbm.a.31583.Search in Google Scholar PubMed

[18] Q. H. Zhang, S. H. Tan, and S. M. Chou, “Investigation of fixation screw pull-out strength on human spine,” J. Biomech., vol. 37, no. 4, pp. 479–485, 2004, https://doi.org/10.1016/j.jbiomech.2003.09.005.Search in Google Scholar PubMed

[19] A. Beumer, M. M. Campo, R. Niesing, J. Day, G. J. Kleinrensink, and B. A. Swierstra, “Screw fixation of the syndesmosis: a cadaver model comparing stainless steel and titanium screws and three and four cortical fixation,” Injury, vol. 36, no. 1, pp. 60–64, 2005, https://doi.org/10.1016/j.injury.2004.05.024.Search in Google Scholar PubMed

[20] R. Zdero, S. Rose, E. H. Schemitsch, and M. Papini, “Cortical screw pullout strength and effective shear stress in synthetic third generation composite femurs,” J. Biomech. Eng., vol. 129, no. 2, pp. 289–293, 2007, https://doi.org/10.1115/1.2540926.Search in Google Scholar PubMed

[21] A. B. Karakullukcu, E. Taban, and O. O. Ojo, “Biocompatibility of biomaterials and test methods: a review,” Mater. Test., vol. 65, no. 4, pp. 545–559, 2023, https://doi.org/10.1515/mt-2022-0195.Search in Google Scholar

[22] Q. Liu, G. Zhao, B. Yu, J. Ma, Z. Li, and K. Zhang, “Effects of inferior tibiofibular syndesmosis injury and screw stabilization on motion of the ankle: a finite element study,” Knee Surg. Sports Traumatol. Arthrosc., vol. 24, no. 4, pp. 1228–1235, 2016, https://doi.org/10.1007/s00167-014-3320-y.Search in Google Scholar PubMed

[23] A. R. Knutsen, et al.., “Distal fibula fracture fixation: biomechanical evaluation of three different fixation implants,” Foot Ankle Surg., vol. 22, no. 4, pp. 278–285, 2016, https://doi.org/10.1016/j.fas.2016.08.007.Search in Google Scholar PubMed

[24] A. Matityahu, et al.., “Reduction of pullout strength caused by reinsertion of 3.5-mm cortical screws,” J. Orthop. Trauma, vol. 27, no. 3, pp. 170–176, 2013, https://doi.org/10.1097/BOT.0b013e31825490b1.Search in Google Scholar PubMed

[25] S. Patil, A. Mahon, S. Green, I. Mcmurtry, and A. Port, “A biomechanical study comparing a raft of 3.5 mm cortical screws with 6.5 mm cancellous screws in depressed tibial plateau fractures,” Knee, vol. 13, no. 3, pp. 231–235, 2006. https://doi.org/10.1016/j.knee.2006.03.003.Search in Google Scholar PubMed

[26] M. Serhan Er, O. Verim, M. Eroglu, L. Altinel, B. Gokce, and S. Tasgetiren, “Biomechanical evaluation of syndesmotic screw design via finite element analysis and taguchi’s method,” J. Am. Podiatric Med. Assoc., vol. 105, no. 1, pp. 14–21, 2015, https://doi.org/10.7547/8750-7315-105.1.14.Search in Google Scholar PubMed

[27] Y. Y. Kim, W. S. Choi, and K. W. Rhyu, “Assessment of pedicle screw pullout strength based on various screw designs and bone densities – an ex vivo biomechanical study,” Spine, vol. 12, no. 2, pp. 164–168, 2012, https://doi.org/10.1016/j.spinee.2012.01.014.Search in Google Scholar PubMed

[28] T. Hirano, et al.., “Structural characteristics of the pedicle and its role in screw stability,” Spine, vol. 22, no. 21, pp. 2504–2510, 1997, https://doi.org/10.1097/00007632-199711010-00007.Search in Google Scholar PubMed

[29] H. Bekler, G. Bulut, M. Usta, A. Gokce, F. Okyar, and T. Beyzadeoglu, “The contribution of locked screw-plate fixation with varying angle configurations to stability of osteoporotic fractures: an experimental study,” Acta Orthop. Traumatol. Turc., vol. 42, no. 2, pp. 125–129, 2008, https://doi.org/10.3944/AOTT.2008.42.2.125.Search in Google Scholar PubMed

[30] C. P. DiPaola, J. A. Jacobson, H. Awad, B. P. Conrad, and G. R. Rechtine, “Screw orientation and plate type (variable- vs. fixed-angle) effect strength of fixation for in vitro biomechanical testing of the Synthes CSLP,” Spine, vol. 8, no. 5, pp. 717–722, 2008, https://doi.org/10.1016/j.spinee.2007.06.016.Search in Google Scholar PubMed

[31] J. E. Tidwell, E. P. Roush, C. L. Ondeck, A. R. Kunselman, J. S. Reid, and G. S. Lewis, “The biomechanical cost of variable angle locking screws,” Injury, vol. 47, no. 8, pp. 1624–1630, 2016, https://doi.org/10.1016/j.injury.2016.06.001.Search in Google Scholar PubMed

[32] K. Q. Robert, R. Chandler, R. V. Baratta, K. A. Thomas, and M. B. Harris, “The effect of divergent screw placement on the initial strength of plate-to-bone fixation,” J. Trauma, vol. 55, no. 6, pp. 1139–1144, 2003, https://doi.org/10.1097/01.TA.0000031103.15337.CA.Search in Google Scholar PubMed

Published Online: 2024-01-23
Published in Print: 2024-03-25

© 2024 Walter de Gruyter GmbH, Berlin/Boston

Downloaded on 28.5.2024 from https://www.degruyter.com/document/doi/10.1515/mt-2023-0239/html
Scroll to top button