Skip to content
Licensed Unlicensed Requires Authentication Published by De Gruyter August 17, 2020

A phasor-distance based faulty phase detection and fault classification technique for parallel transmission lines

  • Nishant Kothari ORCID logo EMAIL logo , Bhavesh R. Bhalja , Vivek Pandya , Pushkar Tripathi and Soumitri Jena

Abstract

This paper presents a phasor-distance based faulty phase detection and fault classification technique for parallel transmission lines. Detection and classification of faulty phase(s) have been carried out by deriving indices from the change in phasor values of current with a distance of one cycle. The derived indices have zero values during normal operating conditions whereas the index corresponding to the faulty phase exceeds the pre-defined threshold in case of occurrence of a fault. A separate ground detection algorithm has been utilized for the identification of involvement of ground in a faulty situation. The performance of the proposed technique has been evaluated for intra-circuit, inter-circuit and simultaneous faults with wide variations in system and fault conditions. The suggested technique has been evaluated for over 23,000 diversified simulated fault cases as well as 14 recorded real fault events. The performance of the proposed technique remains consistent under Current Transformer (CT) saturation as well as different amount and direction of power flow. Moreover, suitability to different power system network has also been studied. Also, faults having fault current less than pre-fault conditions have been detected accurately. The results obtained suggest that it is able to detect faulty phases as well as classify faults within quarter-cycle from the inception of fault with impeccable accuracy. Besides, as modern digital relays have been already equipped with phasor computation facility, phasor-based technique can be easily incorporated with relative ease. At last, a comparative evaluation suggests its superiority in terms of fault classification accuracy, fault detection time, diversify fault scenarios and computational requirement among other existing techniques.


Corresponding author: Nishant Kothari, Department of Electrical Engineering, Marwadi University, Rajkot, Gujarat, India, E-mail:

Acknowledgment

The authors are grateful to the Gujarat Energy Transmission Corporation (GETCO) Limited for their cooperation and support in providing valuable data utilised in this research work.

  1. Author contribution: All the authors have accepted responsibility for the entire content of this submitted manuscript and approved submission.

  2. Research funding: None declared.

  3. Conflict of interest statement: The authors declare no conflicts of interest regarding this article.

Appendix I

Source impedances: Z1 = (0.069 + 2j) Ω, Z0 = (0.2 + 6j) Ω

CT Ratio: 1000/1, Secondary Resistance = 0.5 Ω, Secondary Inductance = 0.8 mH

Transmission Line: Frequency dependent model with configuration as shown in Figure 27.

Figure 27: Transmission line model.
Figure 27:

Transmission line model.

References

1. Apostolov, A, Tholomier, D, Sambasivan, S, Richards, S. Protection of double circuit transmission lines. In: 2007 60th Annual conference for protective relay engineers; 2007:85–101 pp.10.1109/CPRE.2007.359893Search in Google Scholar

2. Makwana, VH, Bhalja, B. New adaptive digital distance relaying scheme for double infeed parallel transmission line during inter-circuit faults. IET Gener Transm Dis 2011;5:667–73. https://doi.org/10.1049/iet-gtd.2010.0707.Search in Google Scholar

3. Osman, A, Malik, O. Protection of parallel transmission lines using wavelet transform. IEEE Trans Power Deliver 2004;19:49–55. https://doi.org/10.1109/tpwrd.2003.820419.Search in Google Scholar

4. Mourad, D, Shehab_Eldin, E. Adaptive single ended protection scheme for parallel transmission lines. In: 2017 Nineteenth international middle east power systems conference (MEPCON); 2017:1208–15 pp.10.1109/MEPCON.2017.8301336Search in Google Scholar

5. Swetapadma, A, Mishra, P, Yadav, A, Abdelaziz, AY. A non-unit protection scheme for double circuit series capacitor compensated transmission lines. Elec Power Syst Res 2017;148:311–25. https://doi.org/10.1016/j.epsr.2017.04.002.Search in Google Scholar

6. Swetapadma, A, Yadav, A. Directional relaying using support vector machine for double circuit transmission lines including cross-country and inter-circuit faults. Int J Electr Power Energy Syst 2016;81:254–64. https://doi.org/10.1016/j.ijepes.2016.02.034.Search in Google Scholar

7. Zin, AAM, Saini, M, Mustafa, MW, Sultan, AR. New algorithm for detection and fault classification on parallel transmission line using DWT and BPNN based on Clarke’s transformation. Neurocomputing 2015;168:983–93. https://doi.org/10.1016/j.neucom.2015.05.026.Search in Google Scholar

8. Abdullah, A. Ultrafast transmission line fault detection using a DWT-based ANN. IEEE Trans Ind Appl 2018;54:1182–93. https://doi.org/10.1109/tia.2017.2774202.Search in Google Scholar

9. Ashok, V, Yadav, A. A protection scheme for cross-country faults and transforming faults in dual-circuit transmission line using real-time digital simulator: a case study of Chhattisgarh state transmission utility. Ira J Sci Tech, Trans Electr Eng 2019;43:941–67. https://doi.org/10.1007/s40998-019-00202-w.Search in Google Scholar

10. Ashok, V, Yadav, A, Anthony, C, Yadav, K, Yadav, U. A reliable decision-making algorithm for fault during power swing in 400 kV double-circuit transmission line: a case study of Chhattisgarh state power system network. In: Decision making applications in modern power systems. Elsevier; 2020:473–506 pp.10.1016/B978-0-12-816445-7.00018-9Search in Google Scholar

11. Jamehbozorg, A, Shahrtash, S. A decision tree-based method for fault classification in double-circuit transmission lines. IEEE Trans Power Deliver 2010;25:2184–9. https://doi.org/10.1109/tpwrd.2010.2050911.Search in Google Scholar

12. Bollen, M. Travelling-wave-based protection of double-circuit lines. In: IEE Proceedings C (generation, transmission and distribution); 1993:37–48 pp.10.1049/ip-c.1993.0006Search in Google Scholar

13. Sharafi, A, Sanaye-Pasand, M, Jafarian, P. Ultra-high-speed protection of parallel transmission lines using current travelling waves. IET Gener Transm Dis 2011;5:656–66. https://doi.org/10.1049/iet-gtd.2010.0767.Search in Google Scholar

14. Zhang, G, Shu, H, Lopes, F, Liao, Y. Single-ended travelling wave-based protection scheme for double-circuit transmission lines. Int J Electr Power Energy Syst 2018;97:93–105. https://doi.org/10.1016/j.ijepes.2017.10.025.Search in Google Scholar

15. Hasheminejad, S, Seifossadat, SG, Razaz, M, Joorabian, M. Traveling-wave-based protection of parallel transmission lines using Teager energy operator and fuzzy systems. IET Gener Transm Distr 2016;10:1067–74. https://doi.org/10.1049/iet-gtd.2015.0947.Search in Google Scholar

16. Chen, C-S, Liu, C-W, Jiang, J-A. A new adaptive PMU based protection scheme for transposed/untransposed parallel transmission lines. IEEE Trans Power Deliver 2002;17:395–404. https://doi.org/10.1109/61.997906.Search in Google Scholar

17. Jiang, J-A, Tseng, C-L, Yu, C-S, Wang, Y-C, Chen, C-S. Digital protective relaying algorithms for double circuit lines protection. In: Proceedings. PowerCon 2002. International conference on power system technology; 2002:2551–5 pp.10.1109/ICPST.2002.1047246Search in Google Scholar

18. Dutta, P, Esmaeilian, A, Kezunovic, M. Transmission-line fault analysis using synchronized sampling. IEEE Trans Power Deliver 2014;29:942–50. https://doi.org/10.1109/tpwrd.2013.2296788.Search in Google Scholar

19. Jena, MK, Samantaray, S. Intelligent relaying scheme for series-compensated double circuit lines using phase angle of differential impedance. Int J Electr Power Energy Syst 2015;70:17–26. https://doi.org/10.1016/j.ijepes.2015.01.035.Search in Google Scholar

20. Das, S, Singh, SP, Panigrahi, BK. Transmission line fault detection and location using wide area measurements. Elec Power Syst Res 2017;151:96–105. https://doi.org/10.1016/j.epsr.2017.05.025.Search in Google Scholar

21. Eissa, M. A new wide-area protection scheme for single-and double-circuit lines using 3-D-phase surface. IEEE Trans Power Deliver 2018;33:2613–23. https://doi.org/10.1109/tpwrd.2018.2808288.Search in Google Scholar

22. Gaur, VK, Bhalja, B. New fault detection and localisation technique for double-circuit three-terminal transmission line. IET Gener Transm Dis 2017;12:1687–96. https://doi.org/10.1049/iet-gtd.2017.1101.Search in Google Scholar

23. Benmouyal, G, Roberts, J. Superimposed quantities: their true nature and application in relays. In: Proceedings of the 26th annual western protective relay conference, Spokane, WA; 1999.Search in Google Scholar

24. Krishnanand, K, Dash, P. A new real-time fast discrete S-transform for cross-differential protection of shunt-compensated power systems. IEEE Trans Power Deliver 2013;28:402–10. https://doi.org/10.1109/tpwrd.2012.2221749.Search in Google Scholar

25. Bhalja, B, Maheshwari, R. Percentage differential protection of double-circuit line using wavelet transform. Electr Power Comp Syst 2007;35:945–54. https://doi.org/10.1080/15325000701199453.Search in Google Scholar

26. Bhalja, B, Purohit, S. Protection of double-circuit transmission line using superimposed current. Electr Power Comp Syst 2011;39:590–604. https://doi.org/10.1080/15325008.2010.528545.Search in Google Scholar

27. Wang, Q, Dong, X, Bo, Z, Caunce, B, Apostolov, A, Tholomier, D. Cross differential protection of double lines based on supper-imposed current. In: CIRED 2005. 18th International conference and exhibition on electricity distribution; 2005:1–4 pp.Search in Google Scholar

28. Muller, C. User’s guide on the use of PSCAD. Manitoba, Canada: Manitoba HVDC Research Centre; 2010.Search in Google Scholar

29. Perera, N, Rajapakse, AD. Series-compensated double-circuit transmission-line protection using directions of current transients. IEEE Trans Power Deliver 2013;28:1566–75. https://doi.org/10.1109/tpwrd.2013.2256934.Search in Google Scholar

30. Solak, K, Rebizant, W. Analysis of differential protection response for cross-country faults in transmission lines. In: 2010 Modern electric power systems; 2010:1–4 pp.Search in Google Scholar

31. Eissa, M, Masoud, M. A novel digital distance relaying technique for transmission line protection. IEEE Trans Power Deliver 2001;16:380–4. https://doi.org/10.1109/61.924814.Search in Google Scholar

32. Hooshyar, A, Sanaye-Pasand, M, El-Saadany, EF. CT saturation detection based on waveshape properties of current difference functions. IEEE Trans Power Deliver 2013;28:2254–63. https://doi.org/10.1109/tpwrd.2013.2266799.Search in Google Scholar

33. Jiang, S, Annakkage, U, Gole, A. A platform for validation of FACTS models. IEEE Trans Power Deliver 2005;21:484–91.10.1109/TPWRD.2005.852301Search in Google Scholar

34. Tripathi, P, Pillai, G, Gupta, HO. Kernel-extreme learning machine-based fault location in advanced series-compensated transmission line. Electr Power Comp Syst 2016;44:2243–55. https://doi.org/10.1080/15325008.2016.1220999.Search in Google Scholar

35. Maezono, PK, Altman, E, Brito, K, Maria, VADSM, Magrin, F. Very high-resistance fault on a 525 kV transmission line-case study. In: 2009 62nd Annual conference for protective relay engineers; 2009:322–32 pp.10.1109/CPRE.2009.4982523Search in Google Scholar

Received: 2020-02-10
Accepted: 2020-07-09
Published Online: 2020-08-17

© 2020 Walter de Gruyter GmbH, Berlin/Boston

Downloaded on 28.4.2024 from https://www.degruyter.com/document/doi/10.1515/ijeeps-2020-0018/html