Abstract
Background: Evaluation of paroxysmal nocturnal hemoglobinuria (PNH) clones by flow cytometry (FCM) is not standardized and is associated with consistent inter-laboratory variability.
Methods: In order to rule out the influence of particular approach in generating final results, we analyzed the performance characteristics of individual consensus strategies for small to intermediate (1%–20%) and minor (<1%) PNH clones within the white blood cell (WBC) and red blood cell (RBC) compartments with sensitivity up to 0.1%.
Results: Coefficient of variation (CV) for precision/reproducibility analysis ranged from 0.67%/1.49% to 2.56%/3.09% for granulocytes, from 0.93%/3.09% to 7.76%/12.06% for monocytes and from 0.41%/4.73% to 6.53%/5.1% for RBCs. Coefficient of determination (r2) for linear regression analysis ranged from 0.95 to 0.99, Wilcoxon ranks test showed no statistically significant differences (p>0.05), Bland-Altman analysis demonstrated performance agreement with mean bias ranging from −0.18 to 1.24.
Conclusions: Our results confirmed very good performance characteristics for precision and reproducibility analysis, excellent correlation and favorable agreement between strategies, suggesting that reported inter-laboratory variability is related mainly to incorrect performance and/or insufficient experience with PNH testing by flow cytometry, rather than to relevant limitations of any particular approach.
References
1. van der Schoot CE, Huizinga TW, van’t Veer-Korthof ET, Wijmans R, Pinkster J, von dem Borne AE. Deficiency of glycosyl-phosphatidylinositol-linked membrane glycoproteins of leukocytes in paroxysmal nocturnal hemoglobinuria, description of a new diagnostic cytofluorometric assay. Blood 1990;76:1853–9.10.1182/blood.V76.9.1853.1853Search in Google Scholar
2. Richards SJ, Rawstron AC, Hillmen P. Application of flow cytometry to the diagnosis of paroxysmal nocturnal hemoglobinuria. Cytometry Part B (Clin Cytom) 2000; 42:223–33.10.1002/1097-0320(20000815)42:4<223::AID-CYTO2>3.0.CO;2-DSearch in Google Scholar
3. Oltenao H, Karandikar NJ, McKenna RW, Xu Y. Differential usefulness of various markers in the flow cytometric detection of paroxysmal nocturnal hemoglobinuria in blood and bone marrow. Am J Clin Pathol 2006;126:781–8.10.1309/AT9Y6WR03PX1K228Search in Google Scholar
4. Sutherland DR, Kuek N, Davidson J, Barth D, Chang C, Yeo EL, et al. Diagnosing PNH with FLAER and multiparameter flow cytometry. Cytometry Part B (Clin Cytom)2007;72B: 167–77.http://gateway.webofknowledge.com/gateway/Gateway.cgi?GWVersion=2&SrcApp=PARTNER_APP&SrcAuth=LinksAMR&KeyUT=000246061000002&DestLinkType=FullRecord&DestApp=ALL_WOS&UsrCustomerID=b7bc2757938ac7a7a821505f8243d9f310.1002/cyto.b.20151Search in Google Scholar
5. Oni SB, Osunkoya BO, Luzzatto L. Paroxysmal nocturnal hemoglobinuria: evidence for monoclonal origin of abnormal red cells. Blood 1970;36:145–52.10.1182/blood.V36.2.145.145Search in Google Scholar
6. Moyo VM, Mukhina GL, Garrett ES, Brodsky RA. Natural history of paroxysmal nocturnal haemoglobinuria using modern diagnostic assays. Br J Haematol 2004;126:133–8.10.1111/j.1365-2141.2004.04992.xSearch in Google Scholar
7. Bessler M, Mason PJ, Hillmen P, Miyata T, Yamada N, Takeda N, et al. Paroxysmal nocturnal hemoglobinuria (PNH) is caused by somatic mutations in the PIG-A gene. EMBO J 1994;13: 110–7.10.1002/j.1460-2075.1994.tb06240.xSearch in Google Scholar
8. Nafa K, Bessler M, Castro-Malaspina H, Jhanwar S, Luzzatto L. The spectrum of somatic mutations in the PIG-A gene in paroxysmal nocturnal hemoglobinuria includes large deletions and small duplications. Blood Cells Mol Dis 1998;24:370–84.10.1006/bcmd.1998.0203Search in Google Scholar
9. Hill A, Hillmen P, Richards SJ, Elebute D, Marsh JC, Chan J, et al. Sustained response and long-term safety of eculizumab in paroxysmal nocturnal hemoglobinuria. Blood 2005;106: 2559–65.10.1182/blood-2005-02-0564Search in Google Scholar
10. Hillmen P, Muus P, Duhrsen U, Risitano AM, Schubert J, Luzzatto L, et al. Effect of the complement inhibitor eculizumab on thromboembolism in patients with paroxysmal nocturnal hemoglobinuria. Blood 2007;110:4123–8.http://gateway.webofknowledge.com/gateway/Gateway.cgi?GWVersion=2&SrcApp=PARTNER_APP&SrcAuth=LinksAMR&KeyUT=000251272200047&DestLinkType=FullRecord&DestApp=ALL_WOS&UsrCustomerID=b7bc2757938ac7a7a821505f8243d9f310.1182/blood-2007-06-095646Search in Google Scholar
11. Hillmen P, Young NS, Schubert J, Brodsky RA, Socie G, Muus P, et al. The complement inhibitor eculizumab in paroxysmal nocturnal hemoglobuniria. N Engl J Med 2006; 355:1233–43.10.1056/NEJMoa061648Search in Google Scholar PubMed
12. Wang SA, Pozdnyakova O, Jorgensen JL, Medeiros LJ, Stachurski D, Anderson M, et al. Detection of paroxysmal nocturnal hemoglobinuria clones in patients with myelodysplastic syndromes and related bone marrow diseases, with emphasis on diagnostic pitfalls and caveats. Haematologica 2009;94:29–37.10.3324/haematol.13601Search in Google Scholar PubMed PubMed Central
13. Galili N, Ravandi F, Palermo G, Bubis J, Illingworth A, Castro-Malaspina H, et al. Prevalence of paroxysmal nocturnal hemoglobinuria (PNH) cells in patients with myelodysplastic syndrome (MDS) aplastic anemia (AA) or other bone marrow failure (BMF)snydromes: interim results from the explore trial. J Clin Oncol 2009;27:15s.10.1200/jco.2009.27.15_suppl.7082Search in Google Scholar
14. Movalia MK, Illingworth A. Identification and clinical significance of type II granulocytes among patients with paroxysmal nocturnal hemoglobinuria (PNH) identified using multiparameter high sensitivity flow cytometry. Blood 2009;114:3015 (abstr).10.1182/blood.V114.22.3015.3015Search in Google Scholar
15. Borowitz MJ, Craig FE, DiGiuseppe JA, Illingworth AJ, Rosse W, Sutherland DR, et al. On behalf of the Clinical Cytometry Society. Guidelines for the diagnosis and monitoring of paroxysmal nocturnal hemoglobinuria and related disorders by flow cytometry. Cytometry Part B (Clin Cytom) 2010; 78B:211–30.http://gateway.webofknowledge.com/gateway/Gateway.cgi?GWVersion=2&SrcApp=PARTNER_APP&SrcAuth=LinksAMR&KeyUT=000279478600001&DestLinkType=FullRecord&DestApp=ALL_WOS&UsrCustomerID=b7bc2757938ac7a7a821505f8243d9f3Search in Google Scholar
16. Sutherland DR, Keeney M, Illingworth A. Practical guidelines for the high-sensitivity detection and monitoring of paroxysmal nocturnal hemoglobinuria clones by flow cytometry. Cytometry Part B (Clin Cytom) 2012;82B(4):195–208.10.1002/cyto.b.21023http://gateway.webofknowledge.com/gateway/Gateway.cgi?GWVersion=2&SrcApp=PARTNER_APP&SrcAuth=LinksAMR&KeyUT=000305556900035&DestLinkType=FullRecord&DestApp=ALL_WOS&UsrCustomerID=b7bc2757938ac7a7a821505f8243d9f3Search in Google Scholar PubMed
17. Marinov I, Kohoutová M, Tkáčová V, Lysák D, Holubová M, Stehlíková O, et al. Intra- and interlaboratory variability of paroxysmal nocturnal hemoglobinuria testing by flow cytometry following the 2012 practical guidelines for high-sensitivity paroxysmal nocturnal hemoglobinuria testing. Cytometry Part B (Clin Cytom) 2013;000B:000–000.http://gateway.webofknowledge.com/gateway/Gateway.cgi?GWVersion=2&SrcApp=PARTNER_APP&SrcAuth=LinksAMR&KeyUT=000320732900005&DestLinkType=FullRecord&DestApp=ALL_WOS&UsrCustomerID=b7bc2757938ac7a7a821505f8243d9f3Search in Google Scholar
18. Parker C, Omine M, Richards S, Nishimura J, Bessler M, Ware R, et al. Diagnosis and management of paroxysmal nocturnal hemoglobinuria. Blood 2005;106:3699–709.http://gateway.webofknowledge.com/gateway/Gateway.cgi?GWVersion=2&SrcApp=PARTNER_APP&SrcAuth=LinksAMR&KeyUT=000254675500002&DestLinkType=FullRecord&DestApp=ALL_WOS&UsrCustomerID=b7bc2757938ac7a7a821505f8243d9f3Search in Google Scholar
19. Richards SJ, Hill A, Hillmen P. Recent advances in the diagnosis, monitoring and management of patients with paroxysmal nocturnal hemoglobinuria. Cytometry Part B (Clin Cytom) 2007;72B:291–8.http://gateway.webofknowledge.com/gateway/Gateway.cgi?GWVersion=2&SrcApp=PARTNER_APP&SrcAuth=LinksAMR&KeyUT=000249104300001&DestLinkType=FullRecord&DestApp=ALL_WOS&UsrCustomerID=b7bc2757938ac7a7a821505f8243d9f310.1002/cyto.b.20358Search in Google Scholar PubMed
20. Sutherland DR, Kuek N, Azcona-Olivera J, Anderson T, Acton E, Barth D, et al. Use of FLAER-based white blood cell assay in the primary screening of PNH clones. Am J Clin Pathol 2009;132:564–72.http://gateway.webofknowledge.com/gateway/Gateway.cgi?GWVersion=2&SrcApp=PARTNER_APP&SrcAuth=LinksAMR&KeyUT=000270503500010&DestLinkType=FullRecord&DestApp=ALL_WOS&UsrCustomerID=b7bc2757938ac7a7a821505f8243d9f310.1309/AJCPMRDZZFQM7YJ4Search in Google Scholar PubMed
©2013 by Walter de Gruyter Berlin Boston