日本機械学会論文集 B編
Online ISSN : 1884-8346
Print ISSN : 0387-5016
アクティブアキュムレータに関する研究 : 液圧回路を伝ぱする高周波流量脈動のアクティブ制振
横田 眞一杣田 久志山口 博嗣
著者情報
ジャーナル フリー

1994 年 60 巻 570 号 p. 484-490

詳細
抄録

The pulsation of flow rate through pipelines caused by hydraulic components (e.g., piston pumps) is one of the most common sources of vibration and noise in hydraulic control systems, particularly in pipelines between pumps and actuators. Among the flow rate pulsations caused by hydraulic piston pumps, which is called fluid borne noise, low-frequency pulsation can be easily absorbed and reduced by a passive element such as an accumulator. However, it is difficult to effectively reduce the high-frequency pulsation such as pulses using the passive elements. This paper deals with an active accumulator which is proposed, newly fabricated and is driven directly by multilayered PZT devices to reduce the flow rate pulsation produced by hydraulic elements in the high-frequency region. The active accumulator has the potential to actively reduce and cancel the variation of high-frequency pulsating flow rate (from 500 Hz to 1 kHz frequency) with hydraulic piston pumps by producing and using the inverse-phase flow by making use of fast-acting piezo device actuators. An active control method is proposed to simultaneously reduce several targeted frequency components of the pulsation without influencing on the other components. The validity and the effectiveness of the method are ascertained experimentally.

著者関連情報
© 社団法人日本機械学会
前の記事 次の記事
feedback
Top