Pages 67-70
In this paper, a pulse tube engine with a linear generator and a displacer with driving rod for using high temperature heat source to generate electricity power is discussed by numerical simulation. It is shown that there is an optimum displacer mass and rod diameter to get optimum efficiency at the condition of the linear motor on resonant condition which can be got by adjust the distance between the cylinder head and the piston head of the linear generator.