動力・エネルギー技術の最前線講演論文集 : シンポジウム
Online ISSN : 2424-2950
セッションID: D102
会議情報
D102 オリフィスの絞り比を変えたときの流れ場(OS6 保全・設備診断技術(1))
釜堀 孝一歌野原 陽一中村 晶村瀬 道雄長屋 行則
著者情報
会議録・要旨集 フリー

詳細
抄録

In order to evaluate the effects of flow field on corrosion rate due to flow accelerated corrosion (FAC), the corrosion rate and flow velocity near wall were measured after an orifice In this study, the difference of flow field downstream from orifices with some aperture ratios was examined using Laser Doppler Velocimetry (LDV) Velocity distributions along the circumferential direction and along the flow direction with each aperture ratios of 0.62, 0.5 and 0.41 were compared, in order to verify the numerically simulated result The diameter of pipe was 50 mm, and the each orifice diameter was 31.0 mm, 25 mm and 20.5 mm, respectively Dependence of orifice aperture ratio on flow field downstream from an orifice was investigated by measurements of streamwise component of time-averaged velocity and standard deviation of velocity downstream from orifices

著者関連情報
© 2013 一般社団法人 日本機械学会
前の記事 次の記事
feedback
Top