To respond the urgent needs of verification, training and drill for full scope severe accident management guidelines (FSSAMG) among nuclear regulators, utilities and research institutes, the FSSAMG verification and drill system is developed. The FSSAMG includes comprehensive scenarios under Power Condition, Shutdown Condition, Spent Fuel Pool Condition, and Refueling Conditions. This article summarized the research and development of validation and drill system for FSSAMG by using the severe accident analysis program MAAP5 (Modular Accident Analysis Program 5). Realistic accident scenarios can be verified and exercised in the developed system to support FSSAMG training, drill, examination and verification.