環境工学総合シンポジウム講演論文集
Online ISSN : 2424-2969
セッションID: 315
会議情報
315 セラミックMF膜を用いた水道用膜ろ過システムの確立(II)(水環境保全技術,大気・水保全技術)
山田 雄司若林 和幸土屋 博嗣川瀬 優治松本 公寿
著者情報
会議録・要旨集 フリー

詳細
抄録

Membrane filtration process has been introduced to many small water purification plants to fulfill the growing demands of cryptosporidium-free water, rationalized operation and maintenance, and dealing with polluted water source. Recently, introduction of membrane filtration process is to being considered by larger purification plants. For those cases, it is required not only small footprints or high water recovery, but also capability of on-site chemical cleaning of the process. Authors performed a demonstration experiment using pilot scale plant equipped with monolith ceramic MF membrane for put this process to practical use in larger plants. As a result, it was demonstrated that the plant has been operated stably under a flux of 4m/d, with periodical chemical cleaning about once in five month, and water recovery rate was 99.9%.

著者関連情報
© 2005 一般社団法人 日本機械学会
前の記事 次の記事
feedback
Top