摘要: 我国西部地区地下水和土壤中富含硫酸盐,危害混凝土结构、减少服役寿命。在浇筑过程中,两层混凝土之间产生冷缝,冷缝面微裂纹多、孔隙大是离子流通的主要通道,是结构盐蚀破坏的薄弱面。通过浇筑间隔为0.25 d、0.5 d、7 d和28 d的带冷缝混凝土试件,经历0次、30次、90次和150次硫酸盐干湿-盐蚀循环,结合压剪试验探究浇筑间隔和干湿-盐蚀周期双因素影响下,混凝土冷缝面的黏结退化规律。结果表明:浇筑间隔越久冷缝面黏附力越低;浇筑间隔越短,冷缝面黏附力变化越明显,呈对数函数关系;干湿-盐蚀循环30次内,浇筑间隔对耐蚀性的影响不显著,干湿-盐蚀循环90次后,浇筑间隔对耐蚀性的影响差异逐渐增大;在浇筑间隔增大和干湿-盐蚀循环次数增加的双重影响下,会加速冷缝面的黏结失效。

关键词: 混凝土, 硫酸盐, 冷缝, 黏附力, 耐蚀性

Abstract: Groundwater and soils in the western regions of China are rich in sulfate, which impairs concrete structures and reduces their service life. During concrete pouring, a cold joint forms between two concrete layers; on its surface, many micro-cracks and large pores serve as the main channels for salt ions to flow and cause a weakness prone to salt erosion damage. This study conducts experimental compression-shear tests on concrete specimens and examines the adhesion degradation of the cold joint surface and its variations under sulfate dry-wet-salt corrosion cycling, focusing on the joints with pouring intervals of 0.25 d, 0.5 d, 7 d and 28 d under the condition of 0, 30, 90 and 150 cycles. The results show that a longer pouring interval lead to lower adhesion on the joint surface while a shorter one to greater variations in the adhesion, which follow a logarithmic relationship. Within 30 dry-wet-salt corrosion cycles, the effect of pouring interval on the corrosion resistance of the joint surface is insignificant, while this effect increases gradually after 90 cycles. Accelerating adhesion failure on the cold joint surface is possible in the case of a long pouring interval and a large number of cycles.

Key words: Kconcrete, sulfate, cold joint, adhesion, corrosion resistance

京ICP备13015787号-3
版权所有 © 2013《水力发电学报》编辑部
编辑部地址:中国北京清华大学水电工程系 邮政编码:100084 电话:010-62783813
本系统由北京玛格泰克科技发展有限公司设计开发  技术支持:support@magtech.com.cn