ABSTRACT
With the development of new power systems, a large number of grid-connected new energy and energy storage power stations with voltage levels of 110kV and below cannot match the traditional AGC control strategy with the grid structure. This brings new challenges to the existing grid AGC control. In view of this situation, this paper proposes the principle of local balance of active power control. Based on this principle, an optimal control method for AGC is proposed. The grid-connected power supplies with voltage levels of 220kV and above and 110kV and below are controlled according to different goals. For the grid-connected new energy and energy storage power stations with voltage levels of 110kV and below, this paper proposes an ACE allocation method that uses cloud data to regulate. The contradiction between regulating cloud data transmission speed and AGC control period is resolved. The proposed method has been deployed and applied in a provincial power grid in southern China for more than 1 year. By running the data, the effectiveness of the proposed method is verified.
- LI Peng, XI Wei, CAI Tiantian, Oncept, Architecture and Key Technologies of Digital Power Grids[J]. Proceedings of the CSEE, 2022, 42(14): 5002-5016.Google Scholar
- CHEN Jingpeng, ZHANG Hongxuan, ZHANG Yong, Design and Strategy Optimization of Unified Frequency Control Areas in China Southern Power Grid for Regional Frequency Regulation Auxiliary Service Market[J]. Power System Technology, 2022, 46(07): 2657-2664.Google Scholar
- GAN Wangwei, CHEN Daojun, CUI Ting, Research on Configuration of Distributed Synchronous Condenser in UHV AC/DC Hybrid Power Grid[J]. Hunan Electric Power, 2022, 42(03): 35-42, 72.Google Scholar
- LI Yangying, XI Lei, GUO Yiguo, Automatic Generation Control Based on the Weighted Double Q-Delayed Update Learning Algorithm[J]. Proceedings of the CSEE, 2022, 42(15): 5459-5471.Google Scholar
- LI Kaibin, CHEN Lei, HE Tingyi, Analysis on Damping Characteristics of Elements and Control Links in Oscillation of Automatic Generation Control[J]. Automation of Electric Power Systems, 2022, 46(04): 170-179.Google Scholar
- SONG Xingrong, WU Jinbo, YANG Zhixue, Multi-source AGC coordination optimization method with Wind-PV-Hydro-Thermal based on multi-objective particle swarm optimization algorithm[J]. Journal of Chongqing University, 2022, 45(07): 13-23.Google Scholar
- HUANG Xinke, WANG Huan, ZHOU Yu, Analysis on Damping Characteristics of Elements and Control Links in Oscillation of Automatic Generation Control[J]. Automation of Electric Power Systems, 2022, 46(14): 150-157.Google Scholar
- LU Dingwen, LIAO Kai, SHEN Yangwu, Research on Maximum Penetration Level of Wind Power Considering Wind Speed Fluctuation and Frequency Constraint[J]. Hunan Electric Power, 2022, 42(01): 23-31.Google Scholar
- XIAO Bai, XING Shiheng, WANG Maochun, Prediction Method of Output Power Long-term Fluctuation Characteristic for Multiple Wind Farms After Aggregation Based on Improved KDE Method and GA-SVM[J]. Electric Power Automation Equipment, 2022, 42(02): 77-84.Google Scholar
- Wu Jinbo, Wen Jinyu, Sun Haishun, Study of control method for improving AC Interconnected grid stability based on energy storage technology[J]. Transactions of China Electrotechnical Society, 2012, 27(6): 261-267.Google Scholar
- HONG Quan, WU Jinbo, LI Li, Analysis and Optimization Discussion on Control System Architecture of Electrochemical Energy Storage Power Station[J]. Hunan Electric Power, 2020, 2022, 42(03): 78-82.Google Scholar
- CAI Xinlei, DONG Kai, MENG Zijie, AGC Command Tracking Control Strategy for Battery Energy Storage Power Station Based on Optimized Dynamic Grouping Technology[J]. Energy Storage Science and Technology, 2022, 11(05): 1475-1481.Google Scholar
- LAN Qiang, ZHOU Yuqing, QIU Yanjun, Adjustable Load Participating in Real-time Dispatching and Control of a Multi-lever Power Grid: Key Technology and Engineering Application[J]. Power System Protection and Control, 2022, 50(06): 141-148.Google Scholar
- GU Wei, REN Jiayi, GAO Jun, Optimal Dispatching Model of Electricity Retailers Considering Distributed Generator and Adjustable Load[J]. Automation of Electric Power Systems, 2017, 41(14): 37-44.Google Scholar
- WU Jinbo, XIONG Shangfeng, Xu Zhaolin, Study on Coordinated Optimization Strategy of Power Network AVC Based on Comprehensive Cost[J]. Power Capacitor & Reactive Power Compensation, 2020, 41(1): 207-214.Google Scholar
- ZHOU Tiegang, WU Jinbo, HE Xiao, Research on Selection Method for AVC Control Command of Continuous Variable Equipment[J]. Hunan Electric Power, 2018, 38(6): 37-41.Google Scholar
- ZHAO Xilin, GONG Chufeng, FU Bo, AGC Control Strategy of Interconnected Power Grid Based on Dynamic Stratification[J]. Power System Technology, 2022, 46(01): 204-212.Google Scholar
- MENG Qingqiang, LI Xiangqi, YU Haifeng, Optimal Planning of Energy Storage Power Station Considering Source-charge Uncetainty[J]. Acta Energiae Solaris Sinica, 2021, 42(10): 415-423.Google Scholar
- LIU Wanfu, CHU Tianshu, ZHAO Shuye, Multi-objective Planning for Grid Structure under UHV Access[J]. Proceedings of the CSU-EPSA, 2021, 33(07): 101-105.Google Scholar
- ZHANG Yong, GUO Jun, LIU Jinbo, Design and Key Technology of Technical Architecture for Infrastructure as a Service (IaaS) Layer in Dispatching and Regulation Cloud Platform[J]. Automation of Electric Power Systems, 2021, 45(02): 114-121.Google Scholar
Recommendations
Optimal Operation Technology of Energy Storage Power Station Based on "Three Stations in One"
ICITEE '22: Proceedings of the 5th International Conference on Information Technologies and Electrical EngineeringAt present, the operation mode of the "three stations in one" energy storage power station is simple and extensive, and generally runs at a depth of 90%. This operation mode cannot realize the maximum value of the energy storage power station due to ...
Multi area AGC scheme using imperialist competition algorithm in restructured power system
Display Omitted PID controller for deregulated two area power system (without GRC) and three area power system (with GRC) is designed using ICA.Parameters of PID has also obtained by genetic algorithm.A comparison of ICA obtained PID and GA obtained PID ...
AGC of restructured multi-area multi-source hydrothermal power systems incorporating energy storage units via optimal fractional-order fuzzy PID controller
Owing to nonlinear structure and uncertain load demand characteristics, expert and intelligent automatic generation control (AGC) is inevitable for coherent operation and control of electric power system. Hence, in this paper, to mitigate the frequency ...