耳鼻と臨床
Online ISSN : 2185-1034
Print ISSN : 0447-7227
ISSN-L : 0447-7227
小児の中等度,高度感音難聴に対する補聴器の適合の検討
古賀 慶次郎川城 信子荒木 昭夫脇 喜久子
著者情報
ジャーナル フリー

1982 年 28 巻 5Supplement3 号 p. 928-932

詳細
抄録

On 12 ears of 10 children with bilateral hearing loss, the hearing threshold SPL levels at 500, 1000, 2000 and 4000 Hz were measured either by a hearing SPL meter or a conventional audiometer. Further the output SPL levels of hearing aids of 10 children were determined while giving 60 dB input at frequencies within speech range.
Thus obtained output SPL levels of hearing aids were compared with the hearing threshold SPL levels for the individual subjects and the differences between them were evaluated. The results were as follows:
1) In cases with moderate hearing loss, the output SPL levels of hearing aids ranged over 20 dB below their hearing threshold SPL levels. In cases with severe hearing loss, the output SPL levels of hearing aids were scattered more and deviated from the hearing threshold SPL levels much greater than in cases with moderate hearing loss. The woking gain of hearing aids in everyday use was found insufficient for hearing loss of all cases in this study.
2) Five children out of 10 subjects used, for 6 months, thier own hearing aids with gain increased. In the 6 months, increase in the gain of hearing aids was found to improve their auditory acuity, though gain of hearing aids could be at most 11 dB above the hearing threshold SPL levels and could not exceed them by 20 dB.

著者関連情報