Paper
23 February 2007 VCSELs for atomic sensors
D. K. Serkland, K. M. Geib, G. M. Peake, R. Lutwak, A. Rashed, M. Varghese, G. Tepolt, M. Prouty
Author Affiliations +
Abstract
A new generation of small low-power atomic sensors, including clocks, magnetometers, and gyroscopes, is being developed based on recently available MEMS and VCSEL technologies. These sensors rely on spectroscopic interrogation of alkali atoms, typically rubidium or cesium, contained in small vapor cells. The relevant spectroscopic wavelengths (in vacuum) are 894.6 nm (D1) and 852.3 nm (D2) for cesium, and 795.0 nm (D1) and 780.2 nm (D2) for rubidium. The D1 wavelengths are either preferred or required, depending on the application, and vertical-cavity surface-emitting lasers (VCSELs) are preferred optical sources because of their low power consumption and circular output beam. This paper describes the required VCSEL characteristics for atomic clocks and magnetometers. The fundamental VCSEL requirement is single-frequency output with tunability to the particular spectroscopic line of interest. Single-polarization and single-transverse-mode operation are implicit requirements. VCSEL amplitude noise and frequency noise are also important because they contribute significantly to the sensor signal-to-noise ratio. Additional desired VCSEL attributes are low cost, low power consumption, and several years of continuous operating lifetime. This paper also describes the 894-nm VCSELs that we have developed for cesium-based atomic sensors. In particular, we discuss VCSEL noise measurements and accelerated lifetime testing. Finally, we report the performance of prototype atomic clocks employing VCSELs.
© (2007) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
D. K. Serkland, K. M. Geib, G. M. Peake, R. Lutwak, A. Rashed, M. Varghese, G. Tepolt, and M. Prouty "VCSELs for atomic sensors", Proc. SPIE 6484, Vertical-Cavity Surface-Emitting Lasers XI, 648406 (23 February 2007); https://doi.org/10.1117/12.715077
Lens.org Logo
CITATIONS
Cited by 43 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Vertical cavity surface emitting lasers

Atomic clocks

Cesium

Sensors

Magnetometers

Rubidium

Signal to noise ratio

RELATED CONTENT

Heading error in an alignment-based magnetometer
Proceedings of SPIE (May 23 2011)
Optomechanical fiber gyroscope
Proceedings of SPIE (October 05 2009)
Narrow linewidth VCSELs for high-resolution spectroscopy
Proceedings of SPIE (February 06 2009)
Performance of an FM cw prototype ladar using a 32...
Proceedings of SPIE (August 21 2003)
Miniaturized laser magnetometers and clocks
Proceedings of SPIE (April 01 2002)

Back to Top