Paper
29 December 1998 Characterization of a geometrically desensitized interferometer for flatness testing
Author Affiliations +
Proceedings Volume 3520, Three-Dimensional Imaging, Optical Metrology, and Inspection IV; (1998) https://doi.org/10.1117/12.334344
Event: Photonics East (ISAM, VVDC, IEMB), 1998, Boston, MA, United States
Abstract
We describe the detailed design of a geometrically desensitized interferometer using two transmission diffraction gratings. A number of models of the instrument are used to eliminate object ghosts and stray light contributions. We then investigate analytically the influence of object slope variations on the instrument precision. We show that the part can be located at a measurement location where the metrology is optimized. Analytical and raytracing models demonstrate excellent agreement with experiment.
© (1998) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Xavier Colonna de Lega, James F. Biegen, Dave Stephenson, and Peter J. de Groot "Characterization of a geometrically desensitized interferometer for flatness testing", Proc. SPIE 3520, Three-Dimensional Imaging, Optical Metrology, and Inspection IV, (29 December 1998); https://doi.org/10.1117/12.334344
Lens.org Logo
CITATIONS
Cited by 4 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Diffraction gratings

Interferometers

Diffraction

Reflection

Optical design

Ray tracing

Geometrical optics

RELATED CONTENT

Optical design and simulation for waveguided AR glasses
Proceedings of SPIE (December 20 2022)
Holographic Optical Elements (HOEs)
Proceedings of SPIE (April 26 1982)
Demystifying the sequential ray-tracing algorithm
Proceedings of SPIE (September 04 2002)

Back to Top