RESISTANCE OF BUILT-UP COLD-FORMED STEEL CHANNEL COLUMNS FILLED WITH CONCRETE

Authors

  • Mohd Syahrul Hisyam Mohd Sani Faculty of Civil Engineering, Universiti Teknologi Mara Pahang, Pahang, Malaysia
  • Fadhluhartini Muftah Faculty of Civil Engineering, Universiti Teknologi Malaysia, Johor, Malaysia
  • Mohd Fakri Muda Faculty of Civil Engineering, Universiti Teknologi Mara Pahang, Pahang, Malaysia
  • Cher Siang Tan Faculty of Civil Engineering, Universiti Teknologi Malaysia, Johor, Malaysia

DOI:

https://doi.org/10.11113/jt.v78.8498

Keywords:

Built-up section, Cold-formed steel, Column, Concrete

Abstract

Cold-formed steel (CFS) channel infilled with concrete could increase its ability and stiffness by avoiding failure due to local buckling. Besides, the built-up bolted CFS channel column could serve as permanent formwork, decreased waste material and yet increase economical construction. This study aims to investigate the strength of built-up CFS channel columns infilled with concrete. Two CFS channel sections are situated face to face, connected and strengthen by using M10 bolts and nuts. Then, the 900 mm built-up column is filled with normal concrete of grade C30. Six samples with different end and central bolt spacing were tested. Material properties of CFS and concrete, and the mechanical properties of bolts are also investigated. From the result, the column with concrete on shortest end bolt spacing gave highest ultimate load and reported 68 – 78 % different when compared to similar column without concrete infilled. The failure mode of the column is global buckling and supports yielding, and the concrete is failed due to cracking and breaking. Equation of the relationship between bolt spacing either at the end or central and ultimate load is established. 

References

Zhang, J-H. and Young, B. 2015. Numerical Investigation And Design Of Cold-Formed Steel Built-Up Open Section Columns With Longitudinal Stiffeners. Thin-walled Structures. 89: 178-191.

Li, Y., Li, Y., Wang, S. and Shen, Z. 2014. Ultimate Load-Carrying Capacity Of Cold-Formed Thin-Walled Columns With Built-Up Box And I Section Under Axial Compression. Thin-walled Structures. 79: 202-217.

Georgieva, I., Schueremans, L., Vandewalle, L. and Pyl, L. 2012. Design Of Built-Up Cold-Formed Steel Columns According To The Direct Strength Method. Procedia Engineering. 40: 119-124.

Young, B. And Ellobody, E. 2006. Experimental Investigation Of Concrete-Filled Cold-Formed High Strength Stainless Steel Tube Columns. Journal Of Construction Steel Research. 62: 484-492.

Ferhoune, N. 2014. Experimental Behaviour Of Cold-Formed Steel Welded Tube Filled With Concrete Made Of Crushed Crystallized Slag Subjected To Eccentric Load. Thin-Walled Structures. 80: 159-166.

Dabaon, M.A., El-Boghdadi, M.H. and Hassanein, M.F. 2009. Experimental Investigation On Concrete-Filled Stainless Steel Stiffened Tubular Stub Columns. Engineering Structures. 31: 300-307.

Shi, X-S., Wang, Q-Y., Zhao, X-L and Collins, F.G. 2015. Structural Behaviour Of Geopolymeric Recycled Concrete Filled Steel Tubular Columns Under Axial Loading. Construction and Building Materials. 81: 187-197.

Ellobody, E. 2013. Numerical Modelling Of Fibre Reinforced Concrete-Filled Stainless Steel Tubular Columns. Thin-walled Structures. 63: 1-12.

Dong, J. F, Wang, Q. Y. and Guan, Z. W. 2013. Structural Behaviour Of Recycled Aggregate Concrete Filled Steel Tube Columns Strengthened By CFRP. Engineering Structures. 48: 532-542.

Tao, Z., Uy, B., Han, L-H. and Wang, Z-B. 2009. Analysis And Design Of Concrete-Filled Stiffened Thin-Walled Steel Tubular Columns Under Axial Compression. Thin-walled Structures. 47: 1544-1556.

Ellobody, E. And Young, B. 2006. Design And Behaviour Of Concrete-Filled Cold-Formed Stainless Steel Tube Columns. Engineering Structures. 28: 716-728.

BS EN 10002-1: 2001. Tensile Testing Of Metallic Materials. Method Of Test At Ambient Temperature.

Reyes, W. and Guzman, A. 2011. Evaluation Of The Slenderness Ratio In Built-Up Cold-Formed Box Sections. Journal of Constructional Steel Research. 67: 929-935.

Downloads

Published

2016-05-08

How to Cite

RESISTANCE OF BUILT-UP COLD-FORMED STEEL CHANNEL COLUMNS FILLED WITH CONCRETE. (2016). Jurnal Teknologi, 78(5-2). https://doi.org/10.11113/jt.v78.8498