To read this content please select one of the options below:

Seismic reduction principle and response analysis of variable damping viscous damper system

Shahe Liang (Architects and Engineers Co., Ltd. of Southeast University, Nanjing, China) (Southeast University, Nanjing, China)
Zhiqiang Zhang (Southeast University, Nanjing, China)
Aiqun Li (Southeast University, Nanjing, China)

International Journal of Structural Integrity

ISSN: 1757-9864

Article publication date: 5 December 2023

Issue publication date: 10 January 2024

64

Abstract

Purpose

A new type of variable damping viscous damper is developed to meet the settings of different damping parameter values at different working stages. Its main principle and design structure are introduced, and the two-stage and multi-stage controllable damping methods are proposed.

Design/methodology/approach

The theoretical calculation formulas of the damping force of power-law fluid variable damping viscous damper at elongated holes are derived, aiming to provide a theoretical basis for the development and application of variable damping viscous dampers. For the newly developed variable damping viscous damper, the dynamic equations for the seismic reduction system with variable damping viscous dampers under a multi-degree-of-freedom system are established. A feasible calculation and analysis method is proposed to derive the solution process of time history analysis. At the same time, a program is also developed using Matlab. The dynamic full-scale test of a two-stage variable damping viscous damper was conducted, demonstrating that the hysteresis curve is complete and the working condition is stable.

Findings

Through the calculation and analysis of examples, the results show that the seismic reduction effect of high and flexible buildings using the seismic reduction system with variable damping viscous dampers is significant. The program developed is used to analyze the seismic response of a broadcasting tower using a variable damping TMD system under large earthquakes. The results indicate that the installation of variable damping viscous dampers can effectively control the maximum inter-story displacement response of TMD water tanks and can effectively consume seismic energy.

Originality/value

This method can provide a guarantee for the safe and effective operation of TMD in wind and vibration control.

Keywords

Acknowledgements

National Science and Technology Support Plan of the 11th Five-Year Plan (2006BAJ03A04).

Citation

Liang, S., Zhang, Z. and Li, A. (2024), "Seismic reduction principle and response analysis of variable damping viscous damper system", International Journal of Structural Integrity, Vol. 15 No. 1, pp. 31-60. https://doi.org/10.1108/IJSI-08-2023-0085

Publisher

:

Emerald Publishing Limited

Copyright © 2023, Emerald Publishing Limited

Related articles