The observation of neutron interference using a crystal interferometer having a separate analyser opens the way to the construction and operation of interferometers with vast arm separation and length. Setting the design specifications requires a three-dimensional dynamical theory model of their operation. This paper develops the required three-dimensional mathematical framework, which also comprises coherent and incoherent illuminations; it is applied to study the visibility of the interference fringes.