Issue 24, 2021

A visualized ratiometric fluorescence sensing system for copper ions based on gold nanoclusters/perovskite quantum dot@SiO2 nanocomposites

Abstract

Excessive copper ions (Cu2+) cause serious environmental pollution and even endanger the health of organisms. Fluorescence chemosensing materials are widely used in the detection of metal ions due to their simple operation and high sensitivity. In this study, SiO2-encapsulated single perovskite quantum dot (PQD@SiO2) core–shell nanostructures which show strong, stable, and green fluorescence are synthesized and composited with gold nanoclusters (AuNCs) which show Cu2+-sensitive and red light-emitting fluorescence to obtain a visualized ratiometric fluorescence sensor (AuNCs/PQD@SiO2) for the detection of Cu2+. In the visualized detection of Cu2+, the green fluorescence emitted from the ion-insensitive PQD@SiO2 component is used as a reference signal and the red fluorescence emitted by ion-sensitive AuNC component is adopted as a sensing signal. In the presence of Cu2+, the red fluorescence is quenched whereas the green fluorescence remains stable, which results in a visualized fluorescence color change from orange-red to yellow and finally to green with increasing Cu2+ concentration. The significant change in the fluorescence color of AuNCs/PQD@SiO2 in response to Cu2+ enables a rapid, sensitive, and visualized detection of Cu2+. Further accurate and sensitive ratiometric fluorescence analysis of Cu2+ can be accomplished by measuring the ratio of fluorescence intensities at 643 and 520 nm (I643/I520) at a certain Cu2+ level. The developed AuNCs/PQD@SiO2-based sensor has been validated by its satisfactory application in the detection of Cu2+ in human serum and environmental water samples.

Graphical abstract: A visualized ratiometric fluorescence sensing system for copper ions based on gold nanoclusters/perovskite quantum dot@SiO2 nanocomposites

Supplementary files

Article information

Article type
Paper
Submitted
13 Oct 2021
Accepted
28 Oct 2021
First published
29 Oct 2021

Analyst, 2021,146, 7545-7553

A visualized ratiometric fluorescence sensing system for copper ions based on gold nanoclusters/perovskite quantum dot@SiO2 nanocomposites

W. Xue, J. Zhong, H. Wu, J. Zhang and Y. Chi, Analyst, 2021, 146, 7545 DOI: 10.1039/D1AN01857D

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements