Simultaneous multi-element and isotope ratio imaging of fish otoliths by laser ablation split stream ICP-MS/MC ICP-MS

Abstract

The simultaneous retrieval of spatially resolved information on the elemental content and isotope ratios from the same sampling spot (e.g. in incrementally grown biological material) still represents an analytical challenge. In order to assess multi-elemental (Sr/Ca; Mg/Ca; Ba/Ca; Na/Ca) and isotopic (87Sr/86Sr) data simultaneously on a fish otolith surface, a laser ablation (LA) system was coupled simultaneously to a multicollector inductively coupled plasma mass spectrometer (MC ICP-MS) and a quadrupole (single collector) ICP-MS via an aerosol split. In addition, a membrane desolvation nebulizer was used for introducing liquid standards in-line to the MC ICP-MS system. The recorded time resolved data of different data density (number of data points/time unit were by a factor of 4 higher using MC ICP-MS) were spatially referenced to the picture using ArcGIS® software. This allowed for the creation of elemental and isotopic images and the combination of data of different spatial resolution. Finally, regions of similar chemical composition were retrieved by cluster analysis. The method was applied to analyze an otolith of a lenok (Brachymystax lenok) caught in the river Eg (northern Mongolia) to assess habitat use and migration in a river system, where only little is known about the migrations of native fish. The combined statistical evaluations of the data showed that the Sr/Ca elemental and 87Sr/86Sr isotope ratios assessed in the otolith were the main discriminators of three clearly different zones on the otolith, indicating habitat shifts. Split-stream LA-ICP-MS/MC ICP-MS proved to be a compelling approach to gain elemental and isotopic data simultaneously from the same sampling spots on solid samples with a minimum loss of information.

Graphical abstract: Simultaneous multi-element and isotope ratio imaging of fish otoliths by laser ablation split stream ICP-MS/MC ICP-MS

Article information

Article type
Paper
Submitted
09 Mar 2016
Accepted
08 Jun 2016
First published
08 Jun 2016

J. Anal. At. Spectrom., 2016,31, 1612-1621

Simultaneous multi-element and isotope ratio imaging of fish otoliths by laser ablation split stream ICP-MS/MC ICP-MS

T. Prohaska, J. Irrgeher and A. Zitek, J. Anal. At. Spectrom., 2016, 31, 1612 DOI: 10.1039/C6JA00087H

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements