Print ISSN:-2395-1354

Online ISSN:-2395-1362

CODEN : IJOSHC

Article History

Received : 30-10-2022

Accepted : 08-11-2022



Article Metrics




Downlaod Files

   


Article Access statistics

Viewed: 434

PDF Downloaded: 398


Fixation stability scoring in inter-trochanteric femur fractures treated with osteosynthesis: A retrospective observational study


Full Text PDF Share on Facebook Share on Twitter


Original Article

Author Details : Pradeep H*, Venkatesh V , Kambam Gowtham Reddy, Markandaiya Acharya

Volume : 8, Issue : 4, Year : 2022

Article Page : 282-290

https://doi.org/10.18231/j.ijos.2022.052



Suggest article by email

Get Permission

Abstract

Objective: To find out the validity of a newly proposed fixation stability scoring system in IT fractures treated with osteosynthesis and its limitations if any.
Materials and Methods: Retrospective analysis of hospital records of patients with various types of intertrochanteric fractures treated surgically at Sri Siddhartha medical college, Tumkur from January 2021 till August 2022. The exclusion criteria were non-ambulatory patients prior to fall, non surgically treated patients, patients loosing follow up or patients who are not alive at the time of study. The scoring was done by three different observers for each patient’s immediate post operative x-ray, repeated at 1 month interval. Radiographs at the final follow up were assessed for fracture union or fixation failure. Parameters of the scoring system: 1) cortical buttress in AP view radiograph, 2) cortical buttress in lateral view radiograph, 3) Tip apex distance (TAD) of principle lag screw, 4) Entry point (in case of IM nail), 5) Location of tip of principle screw in the desired Cleveland zone. 6) Placement of Richard screw in the inferior half of neck (in case of DHS), 7) Use of additional derotation screw (DRS) (in case of DHS).
Results: Scores of all the observers showed statistically significant correlation with fixation failure rates. Results were good with the score of 7.5 and above, fair with 6.5 and above and poor when the score was below 6.5. The minimum acceptable score was 6.5 for extra-medullary devices and 7 for intra-medullary devices.
Conclusion: The newly proposed scoring system appears to be valid and promising intra operative guide for fixation of intertrochanteric fractures with a few limitations. Large scale multi centre prospective studies are needed in the future to support the current study or to further simplify this scoring system.
 

Keywords: Intertrochanteric fracture, Osteosynthesis, Stability score, Fixation failure.



How to cite : Pradeep H, Venkatesh V, Reddy K G, Acharya M, Fixation stability scoring in inter-trochanteric femur fractures treated with osteosynthesis: A retrospective observational study. Indian J Orthop Surg 2022;8(4):282-290


This is an Open Access (OA) journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms.