IP Indian Journal of Orthodontics and Dentofacial Research

Print ISSN: 2581-9356

Online ISSN: 2581-9364

CODEN : IIJOCV

IP Indian Journal of Orthodontics and Dentofacial Research (IJODR) open access, peer-reviewed quarterly journal publishing since 2015 and is published under the Khyati Education and Research Foundation (KERF), is registered as a non-profit society (under the society registration act, 1860), Government of India with the vision of various accredited vocational courses in healthcare, education, paramedical, yoga, publication, teaching and research activity, with the aim of faster and better dissemination of knowledge, we will be publishing the more...

Article type

Original Article


Article page

198-208


Authors Details

Vaibhav Bhatt*, Tejas Motiwale, Geeti V. Mitra


Article Metrics


View Article As

 


Downlaod Files

   






Article statistics

Viewed: 383

PDF Downloaded: 119


Evaluation of the efficacy of Three-dimensional mini plates versus conventional mini plates used in the management of anterior mandibular fractures


Original Article

Author Details : Vaibhav Bhatt*, Tejas Motiwale, Geeti V. Mitra

Volume : 8, Issue : 3, Year : 2022

Article Page : 198-208

https://doi.org/10.18231/j.ijodr.2022.034



Suggest article by email

Get Permission

Abstract

Introduction: The management of mandibular fractures has evolved from closed reduction to open reduction. Champy’s miniplates have become highly popular and is a time-tested method of treatment of mandibular fractures. However, advances like 3D miniplate with claimed advantages like requires less armamentarium, providing better occlusal stability
Materials and Methods: Evaluative study conducted in 24 patients & randomly divided in 2 groups, use of 3D miniplate vs conventional miniplates in anterior mandibular fractures, age group 15-90, post-operative evaluation at day 1, 7 & 3 month, fracture stability, mobility of fracture fragment, complications & bite force.
Result: The level of significance was fixed at 5% and p ? 0.05 was considered statistically significant. 3D mini plating system (p value:- .001)have lesser operating time when compared to 2D conventional miniplating system, also 3D miniplate system have better intraoperative and lesser complications, significantly better bite force results (p value .002*(s)) with 3D miniplate compared to 2D conventional miniplating system.
Conclusion: 3D miniplate a novel form of plating system with better intraoperative and post operative results, better stability compared to conventional miniplating system.
 
Keywords: Champy's miniplates, Fractures, Anterior mandibular, Conventional mini plates


How to cite : Bhatt V, Motiwale T, Mitra G V, Evaluation of the efficacy of Three-dimensional mini plates versus conventional mini plates used in the management of anterior mandibular fractures. IP Indian J Orthod Dentofacial Res 2022;8(3):198-208

This is an Open Access (OA) journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms.