IP Indian Journal of Orthodontics and Dentofacial Research

Print ISSN: 2581-9356

Online ISSN: 2581-9364

CODEN : IIJOCV

IP Indian Journal of Orthodontics and Dentofacial Research (IJODR) open access, peer-reviewed quarterly journal publishing since 2015 and is published under the Khyati Education and Research Foundation (KERF), is registered as a non-profit society (under the society registration act, 1860), Government of India with the vision of various accredited vocational courses in healthcare, education, paramedical, yoga, publication, teaching and research activity, with the aim of faster and better dissemination of knowledge, we will be publishing the more...

Article type

Original Article


Article page

137-144


Authors Details

Anjana S Nair*, Anil Kumar P, Amal S Nair


Article Metrics


View Article As

 


Downlaod Files

   






Article statistics

Viewed: 818

PDF Downloaded: 693


A comparitive evaluation of the shear bond strength of Er:YAG laser ablation on enamel at 3 different power outputs with that of onventional acid etching technique - An invitro study


Original Article

Author Details : Anjana S Nair*, Anil Kumar P, Amal S Nair

Volume : 6, Issue : 3, Year : 2020

Article Page : 137-144

https://doi.org/10.18231/j.ijodr.2020.028



Suggest article by email

Get Permission

Abstract

Background: The aim of this study is to determine whether bonding of stainless steel orthodontic brackets to tooth enamel prepared by laser etching would result in a similar bonding capability as those prepared by acid etching using 37 % phosphoric acid; and also to compare the shear bond strength.
Materials and Methods: Eighty four samples were prepared for the study. The 4 groups were Group 1-The enamel was etched with 37 % phosphoric acid, Group 2- Er: YAG laser etching was done at 1W power output, Group 3- Er: YAG laser etching was done at 2W power output and Group 4- Er:YAG laser etching was done at 3W power output. All groups have 20 teeth for shear bond strength testing and one tooth for SEM evaluation. Shear bond strength testing was performed on all teeth using Instron universal testing machine.
Results: Analysis of the variance indicated a significant difference (P < 0>Conclusion: The results showed that at that laser etching at 2 W to the tooth surface for 15 seconds
had statistically significant higher shear bond strength in comparison to conventional 37% phosphoric acid technique. The use of increasing the laser power output more than 2 W did not significantly increase the bond strength. The shear bond strength of all the three Laser etched groups was clinically acceptable. Enamel etching with Er: YAG Laser (2W for 15 seconds) produced maximum bond strength than acid etching and could be a viable alternative method.

Keywords: Lasers erbium: yttrium - aluminum garnet (Er: YAG) acid etching, Shear bond strength (SBS), Universal Testing Machine (Instron)


How to cite : Nair A S, Anil Kumar P, Nair A S, A comparitive evaluation of the shear bond strength of Er:YAG laser ablation on enamel at 3 different power outputs with that of onventional acid etching technique - An invitro study. IP Indian J Orthod Dentofacial Res 2020;6(3):137-144

This is an Open Access (OA) journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms.