Abstract

Introduction: Acinetobacter spp. are found in moist natural environment and hospital settings. In ICU Acinetobacter spp. is the most common cause of Respiratory tract infection. Acinetobacter spp. has evolved from a minor infection to one of the most virulent and multidrug-resistant, pathogens in intensive care units. Overuses of the antibiotics patients drug resistant pattern are increase and immune compromise patient are not recover early. This research will help in better infection control and a better knowledge of antibiotic resistance patterns in our area. The aim and objective of this study is isolation of Acinetobacter spp. and its antimicrobial resistance pattern in all lower respiratory samples from ICU.
Materials and Methods: All lower respiratory samples were collected (Sputum, BAL, ET etc.) samples was inoculated on MacConkey and blood agar. At 37 degrees Celsius, culture plates were incubated aerobically for 24 hours. Gram staining and biochemical test were used to identify the Acinetobacter species. All species was isolate further processed on the basis of AST by automated through vitek2 compact.
Result: Among 151 samples, 71 (47.01%) were culture positive. Acinetobacter spp. was isolated in 31 (43.66%). The number and percentage of Acinetobacter in various clinical sample were sputum 14 (45.20%), ET 12 (38.70%), pleural fluid 3 (9.60%), BAL 2 (6.50%). The strains showed maximum resistance to Ampicillin (100%) and pipracilline\tazobactum (94.0%), Ceftazidime (86%) followed by gentamycin (77%), Ciprofloxacin (72%). All the strains were sensitive to colistin and Polymyxin B (100%).
Conclusion: The rise of resistant Acinetobacter infection strains has resulted in fewer treatment choices. Because of the limited therapeutic options, infection prevention and control methods, including not only standard measures but also antibiotic management strategies in the ICU, are important.
 

Keywords: Acinetobacter, ICU’s, AST pattern


How to cite : Rani C, Sharma S R, Farooq U, Singh S, Sharma V, Ahamad I, Isolation of Acinetobacter Spp. and its antimicrobial resistance pattern in all lower respiratory samples from ICU. IP Int J Med Microbiol Trop Dis 2022;8(2):118-122


This is an Open Access (OA) journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms.







Article History

Received : 14-03-2022

Accepted : 24-03-2022


View Article

PDF File   Full Text Article


Copyright permission

Get article permission for commercial use

Downlaod

PDF File   XML File   ePub File


Digital Object Identifier (DOI)

Article DOI

https://doi.org/10.18231/j.ijmmtd.2022.024


Article Metrics






Article Access statistics

Viewed: 662

PDF Downloaded: 222



Medical Abbreviation List