Taylor & Francis Group
Browse
tent_a_1629634_sm0935.docx (355.36 kB)

Field demonstration of solar-powered electrocoagulation water treatment system for purifying groundwater contaminated by both total coliforms and arsenic

Download (355.36 kB)
journal contribution
posted on 2019-06-10, 11:18 authored by Chamteut Oh, Seungil Pak, Young-Soo Han, Nguyen Thi Hoang Ha, Moonil Hong, Sangwoo Ji

People who drink groundwater in rural areas of Southeast Asia are exposed to pathogens and arsenic (As)-related health problems. A water treatment system consisting of electrocoagulation reactors, using iron (Fe) electrodes and a filtration tank, was designed to treat complex contaminated groundwater for drinking. Its applicability was demonstrated near the Red River in Vietnam. The water treatment system reduced 10.3 CFU/mL of total coliform and 376 μg/L of As(III) in the groundwater to 0 CFU/mL and 6.68 μg/L, respectively. Total coliforms were attenuated by Fe(II) infiltration or enmeshed during Fe precipitate formation. Of the total As, 43% formed As(III) complexation with the Fe precipitates and the other 57% was oxidized to As(V) then adsorbed to Fe precipitates. The Fe precipitates, containing total coliforms and As, were separated from the discharge water in the filtration tank. The system required 49 W of power to operate, which equates to 423 kWh/year, to continuously purify 0.5 t water/day. This requirement was powered by a 380–750 W solar panel, without external energy supply, making the water treatment system an appropriate option for addressing drinking water problems in rural areas.

History