where expertise comes together - since 1996 -

The Largest Open Access Portal of Nondestructive Testing (NDT)
where expertise comes together
- since 1996 -
Articles
NDT.net Issue: 2024-03
13th Conference on Industrial Computed Tomography (iCT) 2023, 6 - 9 February 2024 in School of Engineering, Wels Campus, Austria (iCT 2024)
Special Issue of e-Journal of Nondestructive Testing (eJNDT) ISSN 1435-4934
Session: Multi Spectral Imaging
Resource Sponsors

Sanying Precision Instruments

Energy-selective X-ray CT imaging with an EIGER2 hybrid photon counting detector in a Diondo d2 XCT system

Jorge Martinez-Garcia1ORCID: 0000-0001-5376-474X2, Damian Gwerder1ORCID: 0000-0002-5843-291X6, David Schiffmann1, Thomas Thuering2, Dubravka Šišak Jung2, Spyridon Gkoumas2ORCID: 0000-0001-8529-1131, Philipp Schuetz1ORCID: 0000-0001-7564-14683
1Competence Centre Thermal Energy Storage; Lucerne University of Applied Sciences and Arts (HSLU)9, Lucerne, Switzerland
2DECTRIS2, Baden, Switzerland

Abstract: Hybrid photon counting (HPC) detector having high spatial resolution and photon energy discrimination capabilities can remarkably improve the quality of X-ray computed tomography (XCT) measurements. In this contribution, we report on the integration of an HPC (EIGER2) detector in a Diondo d2 XCT system and present imaging results for two different samples. It is shown that the detector performs well in the Diondo d2 XCT system allowing to resolve components of different densities in all examined samples. A higher quality of the images was achieved for lower energy threshold values. The integration of the HPC detector required remarkable data postprocessing on the adquired projections as described here.The approach described here enables the exploitation of energy-selective XCT imaging.

Keywords: Computed Tomography (369), X-ray (66), hybrid photon counting, data postprocessing, energy-selective imaging,
*Keywords are freely formed keywords from the authors and thus you may Search also for similar terms.

View:


Comments or Questions?

Share:
Cite:
Martinez-Garcia, J., Gwerder, D., Schiffmann, D., Thuering, T., Jung, D., Gkoumas, S., & Schuetz, P. (2024). Energy-selective X-ray CT imaging with an EIGER2 hybrid photon counting detector in a Diondo d2 XCT system. 13th Conference on Industrial Computed Tomography (iCT) 2023, 6 - 9 February 2024 in School of Engineering, Wels Campus, Austria. e-Journal of Nondestructive Testing . https://doi.org/10.58286/29275
Copyright:
© 2024 The Authors under License CC-BY-4.0

Published: 1 Mar 2024


 Product Spotlight

Black Light UV-LED TYPE UV LED 3P-BS

PICO UV-LED 3P-BS battery type does not require a separate power supply, can be used continuously
...
for more than 4 hours and 30 minutes, and is easy to carry, so it can be applied to various inspections with excellent site accessibility. The portable PICO UV-LED 3P-BS has an ergonomic design considering the safety and convenience of the inspector.
More from "Jorge Martinez-Garcia" (1)
2024-03 Automated drift compensation procedure for high-resolution XCT imaging based on simultaneous measurement of marker sphere

Co-Authored mostly with: D. Gwerder P. Schuetz S. Allner D. Schiffmann A. Bruun

More from "Damian Gwerder" (5)
2024-03 Automated drift compensation procedure for high-resolution XCT imaging based on simultaneous measurement of marker sphere
2023-08 Monitoring of water distribution in meat upon freezing with X-ray computed tomography
2023-08 Study of the solidification behaviour of phase change materials by in-situ X-ray computed tomography
2022-03 Fully volumetric tracking of melting fronts in phase change materials with computed tomography
2022-03 Phase Change Material numerical simulation: enthalpy-porosity model validation against liquid fraction data from a computed tomograph
... All 5 Details >
Co-Authored mostly with: J. Martinez-Garcia D. Guarda P. Schuetz P. Schütz A. Stamatiou





More from "Philipp Schuetz" (2)
2024-03 Automated drift compensation procedure for high-resolution XCT imaging based on simultaneous measurement of marker sphere
2023-08 Study of the solidification behaviour of phase change materials by in-situ X-ray computed tomography
... All 2 Details >
Co-Authored mostly with: D. Gwerder J. Martinez-Garcia B. Fenk S. Gkoumas M. Willner

More from "Lucerne University of Applied Sciences and Arts (HSLU)" (5 of 8)
2024-03 Automated drift compensation procedure for high-resolution XCT imaging based on simultaneous measurement of marker sphere
2023-08 Monitoring of water distribution in meat upon freezing with X-ray computed tomography
2023-08 Study of the solidification behaviour of phase change materials by in-situ X-ray computed tomography
2023-08 Reviewers ECNDT 2023
2022-03 Fully volumetric tracking of melting fronts in phase change materials with computed tomography
... All 8 Details >
Co-Authored mostly with: ... DECTRIS... BAM Federal Institut... MITOS GmbH... University of Padova...

More from "DECTRIS" (1)
2015-08 A Large-Area CdTe Photon-Counting Pixel Detector for High-Energy X-ray Imaging and Diffraction Applications
... All 1 Details >
Co-Authored mostly with: Lucerne University o...

 Product Spotlight

XTR-2022: High Power Ultrasonic Pulse Receiver

The high-power ultrasonic pulser receiver XTR-2022 developed by mkckorea is capable of testing in
...
a wide frequency range from 10kHz to 10MHz up to 700V. For pulse, square pulse method for PZT transducer and square pulse method for EMAT transducer can be used selectively. Therefore, it is a smart device designed to drive PZT transducer and EMAT by one device.

VERMON NDT | Contact PAUT Probes

Master any contact application with our comprehensive line up of state- of-the-art PAUT probes. You
...
can mount these probes on many wedge designs to operate them on scanners or use them for manual inspections. We offer a variety of connector options to mount these probes on all existing ultrasonic generators.

ELOTEST\HST - Heavy Plate Hard Spot Tester

The ELOTEST\HST 3 testing trolley is used for the detection of partial hardening spots on heavy pl
...
ates. The ELOTEST HST-3 is designed for manual testing of large-areas on semi-finished products using the EDDY+ method. The test signals of the integrated ELOTEST\PL650 R eddy current tester are directly displayed as a C-Scan on the fully robust mobile PC (Panasonic Toughbook) included in the scope of delivery.

Flexscan

Flexscan portable phased array ultrasonic testing flaw detector is the latest competitive product
...
made by Doppler. It shares reliable quality and capable performance with Phascan. Smaller size, lighter weight, Hardware upgraded, software improved, more efficiency operation.Flexscan is one of the best solutions for on-site inspection.

Subscribe

Share...
We use technical and analytics cookies to ensure that we will give you the best experience of our website.
More Info
Accept
top
this is debug window