{"_buckets": {"deposit": "e7f9817a-1b21-4cc8-a841-a8725d49707a"}, "_deposit": {"created_by": 2, "id": "2236", "owners": [2], "pid": {"revision_id": 0, "type": "depid", "value": "2236"}, "status": "published"}, "_oai": {"id": "oai:fut.repo.nii.ac.jp:00002236", "sets": ["1"]}, "author_link": ["8000", "7999"], "item_10002_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2022-10-31", "bibliographicIssueDateType": "Issued"}, "bibliographicPageEnd": "054", "bibliographicPageStart": "051", "bibliographic_titles": [{}]}]}, "item_10002_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "In the present study, we attempted to determine trace lead (Pb) in a game pet food by using a method combining pressure acid decomposition and graphite furnace atomic absorption spectrometry (GF-AAS). It was confirmed that there was no contamination by a blank test, and that there was no volatilization of Pb during decomposition by an addition recovery experiment. As a result of four analyzes, the recovery rate exceeded 100% in all cases, but this was due to the small amount of sample collected, which was near the determination limit of GF-AAS (0.4 µg L-1). It was found that the estimated value of the Pb content in the sample obtained from the quantitative results was about 0.2 µg g-1, which was less than the Pb standard value of 3 µg g-1for a pet food. In order to obtain more accurate quantitative results, it is necessary to increase the amount of sample collected.", "subitem_description_type": "Abstract"}]}, "item_10002_identifier_registration": {"attribute_name": "ID登録", "attribute_value_mlt": [{"subitem_identifier_reg_text": "10.57375/00002226", "subitem_identifier_reg_type": "JaLC"}]}, "item_10002_publisher_8": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "福井工業大学"}]}, "item_10002_version_type_20": {"attribute_name": "著者版フラグ", "attribute_value_mlt": [{"subitem_version_resource": "http://purl.org/coar/version/c_970fb48d4fbd8a85", "subitem_version_type": "VoR"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "田中, 智一/ドー ニャット チューン/増實 浩登/松本 直也"}, {"creatorName": "タナカ, トモカズ/ドー ニャット チューン/マスミ ヒロト/マツモト ナオヤ", "creatorNameLang": "ja-Kana"}], "nameIdentifiers": [{"nameIdentifier": "7999", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Tomokazu, Tanaka/Nhat-Truong Do/Hiroto Masumi/Naoya Matsumoto", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "8000", "nameIdentifierScheme": "WEKO"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2023-04-05"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "kiyou5207.pdf", "filesize": [{"value": "3.4 MB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_free", "mimetype": "application/pdf", "size": 3400000.0, "url": {"label": "kiyou5207.pdf", "url": "https://fut.repo.nii.ac.jp/record/2236/files/kiyou5207.pdf"}, "version_id": "c0091ea2-7aae-415d-bc06-891cde247d73"}]}, "item_keyword": {"attribute_name": "キーワード", "attribute_value_mlt": [{"subitem_subject": "Game Pet Food, Lead, Atomic Absorption Spectrometry, Graphite Furnace, Pressure Acid Decomposition", "subitem_subject_language": "en", "subitem_subject_scheme": "Other"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "jpn"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "departmental bulletin paper", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "加圧酸分解/黒鉛炉原子吸光分析法によるジビエペットフード中の鉛の定量", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "加圧酸分解/黒鉛炉原子吸光分析法によるジビエペットフード中の鉛の定量"}, {"subitem_title": "Determination of Lead in a Game Pet Food by Pressure Acid Decomposition / Graphite Furnace Atomic Absorption Spectrometry", "subitem_title_language": "en"}]}, "item_type_id": "10002", "owner": "2", "path": ["1"], "permalink_uri": "https://doi.org/10.57375/00002226", "pubdate": {"attribute_name": "公開日", "attribute_value": "2022-10-31"}, "publish_date": "2022-10-31", "publish_status": "0", "recid": "2236", "relation": {}, "relation_version_is_last": true, "title": ["加圧酸分解/黒鉛炉原子吸光分析法によるジビエペットフード中の鉛の定量"], "weko_shared_id": -1}
加圧酸分解/黒鉛炉原子吸光分析法によるジビエペットフード中の鉛の定量
https://doi.org/10.57375/00002226
https://doi.org/10.57375/00002226d4fc4e5b-b746-4ab6-9a0c-bc6d3773fef3
名前 / ファイル | ライセンス | アクション |
---|---|---|
kiyou5207.pdf (3.4 MB)
|
|
Item type | 紀要論文 / Departmental Bulletin Paper(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2022-10-31 | |||||
タイトル | ||||||
タイトル | 加圧酸分解/黒鉛炉原子吸光分析法によるジビエペットフード中の鉛の定量 | |||||
タイトル | ||||||
言語 | en | |||||
タイトル | Determination of Lead in a Game Pet Food by Pressure Acid Decomposition / Graphite Furnace Atomic Absorption Spectrometry | |||||
言語 | ||||||
言語 | jpn | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | Game Pet Food, Lead, Atomic Absorption Spectrometry, Graphite Furnace, Pressure Acid Decomposition | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | departmental bulletin paper | |||||
ID登録 | ||||||
ID登録 | 10.57375/00002226 | |||||
ID登録タイプ | JaLC | |||||
著者 |
田中, 智一/ドー ニャット チューン/増實 浩登/松本 直也
× 田中, 智一/ドー ニャット チューン/増實 浩登/松本 直也× Tomokazu, Tanaka/Nhat-Truong Do/Hiroto Masumi/Naoya Matsumoto |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | In the present study, we attempted to determine trace lead (Pb) in a game pet food by using a method combining pressure acid decomposition and graphite furnace atomic absorption spectrometry (GF-AAS). It was confirmed that there was no contamination by a blank test, and that there was no volatilization of Pb during decomposition by an addition recovery experiment. As a result of four analyzes, the recovery rate exceeded 100% in all cases, but this was due to the small amount of sample collected, which was near the determination limit of GF-AAS (0.4 µg L-1). It was found that the estimated value of the Pb content in the sample obtained from the quantitative results was about 0.2 µg g-1, which was less than the Pb standard value of 3 µg g-1for a pet food. In order to obtain more accurate quantitative results, it is necessary to increase the amount of sample collected. | |||||
書誌情報 | p. 051-054, 発行日 2022-10-31 | |||||