Published November 4, 2014 | Version 9999750
Journal article Open

Behaviour of Lightweight Expanded Clay Aggregate Concrete Exposed to High Temperatures

Description

This paper is concerning the issues of behaviour of
lightweight expanded clay aggregates concrete exposed to high
temperature. Lightweight aggregates from expanded clay are
produced by firing of row material up to temperature 1050°C.
Lightweight aggregates have suitable properties in terms of volume
stability, when exposed to temperatures up to 1050°C, which could
indicate their suitability for construction applications with higher risk
of fire. The test samples were exposed to heat by using the standard
temperature-time curve ISO 834. Negative changes in resulting
mechanical properties, such as compressive strength, tensile strength,
and flexural strength were evaluated. Also visual evaluation of the
specimen was performed. On specimen exposed to excessive heat, an
explosive spalling could be observed, due to evaporation of
considerable amount of unbounded water from the inner structure of
the concrete.

Files

9999750.pdf

Files (209.2 kB)

Name Size Download all
md5:dc58f5d6f2ff3886ffa6e328b54b8c1a
209.2 kB Preview Download

Additional details

References

  • Technical guide Liapor, Lias Vintirov LSM, 2014.
  • G. H. A. van der Heijden, R.M.W. van Bijnen, L. Pel, H. P. Huinink, "Moisture transport in heated concrete, as studied by NMR, and its consequences for fire spalling," in Cement and concrete research, vol. 37, iss. 6, 2007, pp 894 -901.
  • I. Hager, "Behaviour of cement concrete at high temperature", in Bulletin of the Polish Academy of Sciences: Technical Sciences, vol. 61, iss. 1, 2013.
  • A. Dufka, F. Khestl, "Determination of the degradation level in firedamaged RC constructions," in Proceedings and Monographs in Engineering Water and Earth Sciences, 6th International Conference on Fracture Mechanics of Concrete and Concrete Structures, Fracture mechanics of concrete and concrete structures, Vol. 1-3, pp. 1767- 1771, 2007.
  • M. Zeiml, R. Lackner, D. Leithner, J. Eberhardsteiner, "Identification of residual gas-transport properties of concrete subjected to high temperatures," in Cement and Concrete Research, vol. 38(5), 2008, pp. 699-716.
  • P. Reiterman, M. Keppert, O. Holcapek, Z. Kadlecova, K. Kolar, "Permeability of Concrete Surface Layer," in Proc. of the 50th Annual Conference on Experimental Stress Analysis, Tabor, Czech Republic, 2012, pp. 361-368.
  • Pavus, "Protocol on the classification of fire resistance No. PK2-03-10- 004-C-0 Bearing ceilings and roofs with fire separating function EN 13501-2+A1:2010", Prague, 2010.
  • EN 1365-2 Fire resistance tests for loadbearing elements - Part 2: Floors and roofs.
  • EN 12350-6 Testing fresh concrete - Part 6: Density. [10] EN 12350-2 Testing fresh concrete - Part 2: Slump-test. [11] EN 12390-7 Testing hardened concrete - Part 7: Density of hardened concrete. [12] EN 12390-3 Testing hardened concrete - Part 3: Compressive strength of test specimens. [13] EN 12390-5 Testing hardened concrete - Part 5: Flexural strength of test specimens. [14] EN 1991-1-2 Eurocode 1: Actions on structures - Part 1-2: General actions - Actions on structures exposed to fire.