Space Station Freedom (SSF) will be required to vent water during non-quiescent periods. During Man Tended Configuration (MTC), before the Environmental Control and Life Support System (ECLSS) water loop is closed, humidity condensate will be periodically vented. At Permanently Manned Configuration (PMC), water will be vented on contingency if there is excess water on SSF. The thrust due to venting must be minimized to be considered non-propulsive. Also, ice formation and clogging of the vent nozzle must be avoided. Many aspects of the Space Shuttle water vent design were utilized in development of the preliminary SSF water vent design presented in this paper. Design modifications which improved the shuttle vent as well as those necessary for SSF are discussed. The exterior vent location, direction and environment on SSF are unique compared to previous space water vent designs. From data collected in the vent tests and analyses, a finalized SSF water vent design will be developed.
Recommended Content
Authors
Citation
Miernik, J., Worden, E., Bedard, J., and Lieu, B., "Water Vent Design for Space Station Freedom," SAE Technical Paper 921116, 1992, https://doi.org/10.4271/921116.Also In
References
- Lin, C. L. Rotter, H. A. “Shuttle Supply and Waste Water Dump Nozzles Icing Prevention Evaluation” JSC 19168 doc. # CSD-SH-291 Jan. 1985
- Lieu, B. H. “ECLSS Vent Preliminary Design Final Report” Boeing memo # 2-5332-BHL91-100 Sept. 1991
- “Space Shuttle Systems Handbook” 1 JSC-11174 21 Dec. 1990
- “Test Report Overboard Dumping Functional Model (Selection of Significant Experiments)” Dornier GmbH. DN: RP-DS-1002 10 Aug. 1976 Fuchs H.
- “MSFC Skylab Lessons Learned” NASA TM X-64860 MSCF July 1974
- “Skylab Lessons Learned as Applicable to a Large Space Station” NASA TM X-73073 Schneider W. C. NASA Headquarters Apr. 1976
- “Reevaluation of the Skylab Vent Plume Impingement Effects on the Vehicle Orbital Attitude and Cluster Leakage” Rev. A, LMSC TM-54/20-284-A Aug. 1971
- “Space Station External Contamination Control Requirements” SSP 30426 Rev. B
- Pike C. P. et. ala. “Release of Liquid Water from the Space Shuttle” Geophys. Res. Let. 17 2 139 142 Feb. 1990
- Fowler M. E. et. ala. “Contamination of Spacecraft by Recontact of Dumped Fluids” Geophys. Res. Let. 18 99 104