CC BY-NC-ND 4.0 · Indian J Radiol Imaging 2016; 26(03): 386-396
DOI: 10.4103/0971-3026.190408
Musculoskeletal

Thumb ultrasound: Technique and pathologies

Jatinder P Singh
Department of Imaging and Nuclear Medicine, Medanta, The Medicity, Gurgaon, Haryana, India
,
Shwetam Kumar
Department of Imaging and Nuclear Medicine, Medanta, The Medicity, Gurgaon, Haryana, India
,
Atman V Kathiria
Department of Imaging and Nuclear Medicine, Medanta, The Medicity, Gurgaon, Haryana, India
,
Rachit Harjai
Department of Imaging and Nuclear Medicine, Medanta, The Medicity, Gurgaon, Haryana, India
,
Akram Jawed
Bone and Joint Institute, Medanta, The Medicity, Gurgaon, Haryana, India
,
Vikas Gupta
Bone and Joint Institute, Medanta, The Medicity, Gurgaon, Haryana, India
› Author Affiliations
Financial support and sponsorship Nil.

Abstract

Ultrasound is ideally suited for the assessment of complex anatomy and pathologies of the thumb. Focused and dynamic thumb ultrasound can provide a rapid real-time diagnosis and can be used for guided treatment in certain clinical situations. We present a simplified approach to scanning technique for thumb-related pathologies and illustrate a spectrum of common and uncommon pathologies encountered.



Publication History

Article published online:
30 July 2021

© 2016. Indian Radiological Association. This is an open access article published by Thieme under the terms of the Creative Commons Attribution-NonDerivative-NonCommercial-License, permitting copying and reproduction so long as the original work is given appropriate credit. Contents may not be used for commercial purposes, or adapted, remixed, transformed or built upon. (https://creativecommons.org/licenses/by-nc-nd/4.0/).

Thieme Medical and Scientific Publishers Private Ltd.
A-12, Second Floor, Sector -2, NOIDA -201301, India

 
  • References

  • 1 Eaton RG, Glickel SZ. Trapeziometacarpal osteoarthritis: Staging as a rationale for treatment. Hand Clin 1987;3:455-71.
  • 2 Rousset P, Vuillemin-Bodaghi V, Laredo JD, Parlier-Cuau C. Anatomic variations in the first extensor compartment of the wrist: Accuracy of US. Radiology 2010;257:427-33.
  • 3 Choi SJ, Ahn JH, Lee YJ, Ryu DS, Lee JH, Jung SM, et al. de Quervain disease: US identification of anatomic variations in the first extensor compartment with an emphasis on subcompartmentalization. Radiology 2011;260:480-6.
  • 4 Griffin M, Hindocha S, Jordan D, Saleh M, Khan W. An Overview of the management of flexor tendon injuries. Open Orthop J 2012;6:28-35.
  • 5 Griffin M, Hindocha S, Jordan D, Saleh M, Khan W. Management of Extensor Tendon Injuries. Open Orthop J 2012;6:36-42.
  • 6 Shields JS, Chhabra AB, Pannunzio ME. Acute calcific tendinitis of the hand: 2 case reports involving the abductor pollicis brevis. Am J Orthop 2007;36:605-7.
  • 7 Guerini H, Pessis E, Theumann N, Le Quintrec JS, Campagna R, Chevrot A, et al. Sonographic appearance of trigger fingers. J Ultrasound Med 2008;27:1407-13.
  • 8 Serafini G, Derchi LE, Quadri P, Martinoli C, Orio O, Cavallo A, et al. High resolution sonography of the flexor tendons in trigger fingers. J Ultrasound Med 1996;15:213-9.
  • 9 Peters-Veluthamaningal C, van der Windt DA, Winters JC, Meyboom-de Jong B. Corticosteroid injection for trigger finger in adults. Cochrane Database Sys Rev 2009:CD005617.
  • 10 Benson LS, Ptaszek AJ. Injection versus surgery in the treatment of trigger finger. J Hand Surg Am 1997;22:138-44.
  • 11 Rajeswaran G, Lee JC, Eckersley R, Katsarma E, Healy JC. Ultrasound-guided percutaneous release of the annular pulley in trigger digit. Eur Radiol 2009;19:2232-7.
  • 12 Ebrahim FS, De Maeseneer M, Jager T, Marcelis S, Jamadar DA, Jacobson JA. US diagnosis of UCL tears of the thumb and Stener lesions: Technique, pattern-based approach, and differential diagnosis. Radiographics 2006;26:1007-20.
  • 13 Hergan K, Mittler C, Oser W. Pitfalls in sonography of the gamekeepers' thumb. Eur Radiol 1997;7:65-9.
  • 14 Melville D, Jacobson JA, Haase S, Brandon C, Brigido MK, Fessell D. Ultrasound of displaced ulnar collateral ligament tears of the thumb: The Stener lesion revisited. Skeletal Radiol 2013;42:667-73.
  • 15 Kosiyatrakul A, Jitprapaikulsarn S, Durand S, Oberlin C. Closed flexor pulley rupture of the thumb: Case report and review of literature. Hand Surg 2009;14:139-42.
  • 16 Bayat A, Shaaban H, Giakas G, Lees VC. The pulley system of the thumb: Anatomic and biomechanical study. J Hand Surg Am 2002;27:628-35.
  • 17 Bianchi S, Della Santa D, Glauser T, Beaulieu JY, van Aaken J. Sonography of masses of the wrist and hand. AJR Am J Roentgenol 2008;191:1767-75.
  • 18 Teefey SA, Dahiya N, Middleton WD, Gelberman RH, Boyer MI. Ganglia of the hand and wrist: A sonographic analysis. AJR Am J Roentgenol 2008;191:716-20.
  • 19 Wang G, Jacobson JA, Feng FY, Girish G, Caoili EM, Brandon C. Sonography of wrist ganglion cysts: Variable and noncystic appearances. J Ultrasound Med 2007;26:1323-8.
  • 20 Middleton WD, Patel V, Teefey SA, Boyer MI. Giant cell tumors of the tendon sheath: Analysis of sonographic findings. AJR Am J Roentgenol 2004;183:337-9.
  • 21 Fornage BD, Tassin GB. Sonographic appearances of superficial soft tissue lipomas. J Clin Ultrasound 1991;19:215-20.
  • 22 Inampudi P, Jacobson JA, Fessell DP, Carlos RC, Patel SV, Delaney-Sathy LO, et al. Soft-tissue lipomas: Accuracy of sonography in diagnosis with pathologic correlation. Radiology 2004;233:763-7.
  • 23 Marzano L, Failoni S, Gallazzi M, Garbagna P. The role of diagnostic imaging in synovial sarcoma: Our experience. Radiol Med 2004;107:533-40.
  • 24 Boyse TD, Fessell DP, Jacobson JA, Lin J, van Holsbeeck MT, Hayes CW. US of soft-tissue foreign bodies and associated complications with surgical correlation Radiographics 2001;21:1251-6.
  • 25 Tahmasebi M, Zareizadeh H, Motamedfar A. Accuracy of ultrasonography in detecting radiolucent soft-tissue foreign bodies. Indian J Radiol Imaging 2014;24:196-200.