Abstract
Background
Complex AO type C3 fractures of the distal femur are challenging injuries, fraught with complications such as malunion and stiffness. We prospectively evaluated a consecutive series of patients with complex AO type C3 distal femur fractures to determine the clinicoradiological outcome after fixation with a single locked plate using modified swashbuckler approach.
Materials and Methods
12 patients with C3 type distal femur fractures treated with a lateral locked plate, using a modified swashbuckler approach, were included in the study. The extraarticular component was managed either by compression plating or bridge plating (transarticular approach and retrograde plate osteosynthesis) depending on the fracture pattern. Primary bone grafting was not done in any case. The clinical outcome at 1 year was determined using the Knee Society Score (KSS). The presence of any secondary osteoarthritis in the knee joint was noted at final followup.
Results
All fractures united at a mean of 14.3 ± 4.7 weeks (range 6–26 weeks). There were no significant complications such as nonunion, deep infection, and implant failure. One of the patients underwent secondary bone grafting at 3 months. The mean range of motion of the knee was 120° ± 14.8° (range 105°–150°). Seven patients had excellent, three patients had good and two patients had a fair outcome according to the KSS at 1 year. At a mean followup of 17.6 months, three patients showed radiological evidence of secondary osteoarthritis of the knee joint. However, only one of these patients was symptomatic.
Conclusion
The results of complex C3 type distal femur fractures, fixed with a single lateral locked plate using a modified swashbuckler approach, are encouraging, with a majority of patients achieving good to excellent outcome at 1 year.
Similar content being viewed by others
References
Hutson JJ Jr., Zych GA. Treatment of comminuted intraarticular distal femur fractures with limited internal and external tensioned wire fixation. J Orthop Trauma 2000;14:405–13.
Ramesh LJ, Rajkumar SA, Rajendra R, Rajagopal HP, Phaneesha MS, Gaurav S. Ilizarov ring fixation and fibular strut grafting for C3 distal femoral fractures. J Orthop Surg (Hong Kong) 2004;12:91–5.
Lin D, Chen C, Lian K, Zhai W. Treatment of type C3.3 distal femoral fractures with double-plating fixation via U-shaped incision. Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi 2010;24:683–6.
Zhang ZM, Liu J, Huang CX, Zhao ZF, Wang G, Qin CC. Treatment of type C3 distal femoral fractures with double-plating fixation via anteriormiddle approach. Zhongguo Gu Shang 2012;25:1049–52.
Khalil AE, Ayoub MA. Highly unstable complex C3-type distal femur fracture: Can double plating via a modified Olerud extensile approach be a standby solution? J Orthop Traumatol 2012;13:179–88.
STrbu PD, Asaftei R, Petreus T, Lupascu C, Puha B, Lunca S. Transarticular approach and retrograde plate osteosynthesis (TARPO) using implants with angular stability – A series of 17 cases of complex distal femoral fractures type C3/AO. Chirurgia (Bucur) 2014;109:233–7.
Krettek C, Schandelmaier P, Miclau T, Bertram R, Holmes W, Tscherne H. Transarticular joint reconstruction and indirect plate osteosynthesis for complex distal supracondylar femoral fractures. Injury 1997;28 Suppl 1:A31–41.
Kregor PJ. Distal femur fractures with complex articular involvement: Management by articular exposure and submuscular fixation. Orthop Clin North Am 2002;33:153–75, ix.
Egund N, Kolmert L. Deformities, gonarthrosis and function after distal femoral fractures. Acta Orthop Scand 1982;53:963–74.
Rademakers MV, Kerkhoffs GM, Sierevelt IN, Raaymakers EL, Marti RK. Intraarticular fractures of the distal femur: A long term followup study of surgically treated patients. J Orthop Trauma 2004;18:213–9.
Zehntner MK, Marchesi DG, Burch H, Ganz R. Alignment of supracondylar/intercondylar fractures of the femur after internal fixation by AO/ASIF technique. J Orthop Trauma 1992;6:318–26.
Schatzker J. Fractures of the distal femur revisited. Clin Orthop Relat Res 1998;347:43–56.
Starr AJ, Jones AL, Reinert CM. The swashbuckler: A modified anterior approach for fractures of the distal femur. J Orthop Trauma 1999;13:138–40.
Olerud S. Operative treatment of supracondylar – Condylar fractures of the femur. Technique and results in fifteen cases. J Bone Joint Surg Am 1972;54:1015–32.
Collicott PE. Advanced trauma life support (ATLS): Past, present, future-16th Stone Lecture, American Trauma Society. J Trauma 1992;33:749–53.
Marsh JL, Slongo TF, Agel J, Broderick JS, Creevey W, DeCoster TA, et al. Fracture and dislocation classification compendium – 2007: Orthopaedic Trauma Association classification, database and outcomes committee. J Orthop Trauma 2007;21 10 Suppl: S 1–133.
Insall JN, Dorr LD, Scott RD, Scott WN. Rationale of the knee society clinical rating system. Clin Orthop Relat Res 1989;248:13–4.
Asif S, Choon DS. Midterm results of cemented Press Fit Condylar Sigma total knee arthroplasty system. J Orthop Surg (Hong Kong) 2005;13:280–4.
Henry AK. Extensile Exposure. Edinburgh: Livingstone; 1959. p. 199.
Zlowodzki M, Bhandari M, Marek DJ, Cole PA, Kregor PJ. Operative treatment of acute distal femur fractures: Systematic review of 2 comparative studies and 45 case series (1989 to 2005). J Orthop Trauma 2006;20:366–71.
Henderson CE, Lujan TJ, Kuhl LL, Bottlang M, Fitzpatrick DC, Marsh JL 2010 mid-America Orthopaedic Association Physician in Training Award: Healing complications are common after locked plating for distal femur fractures. Clin Orthop Relat Res 2011;469:1757–65.
Henderson CE, Kuhl LL, Fitzpatrick DC, Marsh JL. Locking plates for distal femur fractures: Is there a problem with fracture healing? J Orthop Trauma 2011;25 Suppl 1:S 8–14.
Hwang JH, Oh JK, Oh CW, Yoon YC, Choi HW. Mismatch of anatomically pre-shaped locking plate on Asian femurs could lead to malalignment in the minimally invasive plating of distal femoral fractures: A cadaveric study. Arch Orthop Trauma Surg 2012;132:51–6.
Siliski JM, Mahring M, Hofer HP. Supracondylar-intercondylar fractures of the femur. Treatment by internal fixation. J Bone Joint Surg Am 1989;71:95–104.
Zlowodzki M, Williamson S, Cole PA, Zardiackas LD, Kregor PJ. Biomechanical evaluation of the less invasive stabilization system, angled blade plate, and retrograde intramedullary nail for the internal fixation of distal femur fractures. J Orthop Trauma 2004;18:494–502.
Author information
Authors and Affiliations
Corresponding author
Additional information
This is an open access article distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 3.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as the author is credited and the new creations are licensed under the identical terms.
Rights and permissions
About this article
Cite this article
Agrawal, A., Kiyawat, V. Complex AO type C3 distal femur fractures: Results after fixation with a lateral locked plate using modified swashbuckler approach. IJOO 51, 18–27 (2017). https://doi.org/10.4103/0019-5413.197516
Published:
Issue Date:
DOI: https://doi.org/10.4103/0019-5413.197516
Key words
- Distal femur fracture
- complex distal femur fractures
- intraarticular distal femur fractures
- swashbuckler approach