Comparison between the RCF Performance of TiN- and TiO2-Laser Coated Ti64 Bearings

Article Preview

Abstract:

The present work is a comparison between the rolling contact fatigue (RCF) of laser processed titanium bearings by using a scanning Nd:YAG Q-sw laser. TiN and TiO2 layers were produced on Ti6Al4V (Ti64) in a closed chamber in nitrogen and air atmosphere, respectively. The average thickness of the layers was 2 m in case of TiN and 0.8 m in case of TiO2. Both non-coated and coated bearings were RCF tested in under-water conditions and it was found that laser processing greatly improved their wear resistance and load capacity. Almost 50-fold and 20-fold increase in the wear resistance of the TiN and TiO2-coated bearings was observed after 7.7x106 cycles at a load of 150 N and 600 rpm. The mechanism responsible for this improvement is thought to be the 3-body-contact between the bearing elements and the small TiN and TiO2 debris, coming from the worn coating layers. The maximum load capability of the non-coated, TiN-coated and TiO2-coated bearings were 150 N, 200 N and 600 N. It is concluded that the higher load capacity of the TiO2 compared to the TiN coatings is due to its lower coefficient of friction.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

308-312

Citation:

Online since:

September 2012

Export:

Price:

[1] T. Bell, P.H. Morton, A. Bloyce, Towards the design of dynamically loaded titanium engineering components, Materials Science and Engineering, A184, 1994, pp.73-86.

DOI: 10.1016/0921-5093(94)91022-7

Google Scholar

[2] T. Bell, H. W. Bergman, J. Lanagan, P. H. Morton, A. M. Staines, Surface engineering of titanium with nitrogen, Surface engineering, Vol. 2, 1986, pp.133-143.

DOI: 10.1179/sur.1986.2.2.133

Google Scholar

[3] A. Bloyce, Wear protection of titanium alloys, Surface performance of titanium, ASM-TMS, (1997).

Google Scholar

[4] D. M. Brunette, P. Tengvall, M. Textor, P. Thomsen, P., Titanium in medicine: material science, surface science, engineering, biological response and medical applications, Springer, (2001).

DOI: 10.1007/978-3-642-56486-4

Google Scholar

[5] P. P. Lutton, B. Ben-Nissan, The status of biomaterials for orthopaedic and dental applications: part I - materials, Materials Technology, Vol. 12, 1997, pp.107-111.

DOI: 10.1080/10667857.1997.11752739

Google Scholar

[6] S. A. Brown, J. E. Lemons, Medical Applications of Titanium and Its Alloys: The Material and Biological Issues, ASTM special technical publication, May 1996, USA.

Google Scholar

[7] E.C. Santos, M. Shiomi, M. Morita, K. Osakada, F. Abe, Laser Nitriding of Titanium Models made by Selective Laser Melting, The Proceedings of the 2004 Japanese Spring Conference for the Technology of Plasticity, Tokyo, Japan, May 2004, pp.107-108.

Google Scholar

[8] E. Gyorgy, A. P. del Pino, P. Serra, J. L. Morenza, Depth profiling characterization of the surface layer obtained by pulsed Nd: YAG laser irradiation of titanium in nitrogen, Surface and coatings technology, Vol. 173, 2003, pp.265-270.

DOI: 10.1016/s0257-8972(03)00520-6

Google Scholar

[9] J. Folkes, D. R. F. West, W. M. Steen, Laser Surface melting and alloying of titanium, Laser Surface Treatment of Metals, Series E: Applied Sciences, 1986, No. 115, NATO ASI Series, pp.451-459.

DOI: 10.1007/978-94-009-4468-8_39

Google Scholar

[10] E. C. Santos, M. Morita, M. Shiomi, K. Osakada, M. Takahashi, Laser gas nitriding of pure titanium using CW and pulsed Nd: YAG lasers, Surface and Coatings Technology, Volume 201, 2006, pp.1635-1642.

DOI: 10.1016/j.surfcoat.2006.02.048

Google Scholar

[11] J. Rozwadowska, E.C. Santos, T. Honda, H. Koike, K. Kida, Y. Kashima, K. Kanemasu, Improvement of the rolling contact fatigue of titanium by Q-sw laser nitriding, Processing and Fabrication of Advanced Materials XIX, New Zealand, January, (2011).

DOI: 10.4028/www.scientific.net/amm.83.191

Google Scholar