Abstract:

The purpose of this research is to detect the atomic spectrum of cesium using laser-induced breakdown spectroscopy (LIBS). In this study, pollucite ((Cs,Na)(AlSi2)O6.nH2O) was used as a test sample for the LIBS measurement. LIBS is a useful tool for the determination of the elemental composition of various materials and it does not require any preprocessing step. The Nd:YAG laser was operated at 1064 nm to generate a 50-mJ Q-switched pulse with a width of 8 ns (full width at half maximum, FWHM). The breakdown emissions were dispersed by a grating with a groove density of 1200 lines/mm and the resulting electrical signal was recorded using a streak camera. The plasma intensity was optimized with respect to the background. Spectral measurements were carried out after an appropriate delay time to allow for the decay of the continuum radiation. In the experiments, 100 laser shots were used to record data for each spectrum in ambient air. The results of the experiments showed that the atomic signals corresponding to pollucite were obtained easily by LIBS measurements. Thus, spectrum peaks due to cesium, sodium, aluminum, and silicon are observed. In particular, the characteristics of the cesium spectrum play an important role in establishing the LIBS system for environmental monitoring, which may be used to detect radioactive elements emitted from nuclear plants.

You might also be interested in these eBooks

Info:

Periodical:

Solid State Phenomena (Volume 199)

Pages:

285-290

Citation:

Online since:

March 2013

Export:

Price:

[1] D.A. Cremers, L.J. Radziemski, T.R. Loree, Spectrochemical analysis of liquids using the laser spark, Appl. Spectr., 38 Issue 5 (1984) 721-729.

DOI: 10.1366/0003702844555034

Google Scholar

[2] L. Frey, S. Kubodera, P.J. Wisoff, R. Sauerbrey, Spectroscopy and kinetics of the ionic cesium fluoride excimer excited by a laser-produced plasma, J. Opt. Soc. Am. B, 6 Issue 8 (1989) 1529-1535.

DOI: 10.1364/josab.6.001529

Google Scholar

[3] W. Hübert, G. Ankerhold, Elemental misinterpretation in automated analysis of LIBS spectra, Anal Bioanal Chem (2011), Springer-Verlag (2011).

DOI: 10.1007/s00216-011-4793-x

Google Scholar

[4] O. Samek, D. C. S. Beddows, J. Kaiser, S. V. Kukhlevsky, M. Liska, H. H. Telle, and J. Young, Application of laser-induced breakdown spectroscopy to in situ analysis of liquid samples, Opt. Eng., vol. 39, p.2248–2262, Aug., (2000).

DOI: 10.1117/1.1304855

Google Scholar

[5] J. Uebbing, J. Brust, W. Sdorra, F. Leis, and K. Niemax, Reheating of a laser-produced plasma by a second pulse laser, Appl. Spectrosc., vol. 45, p.1419–1423, Sep., (1991).

DOI: 10.1366/0003702914335445

Google Scholar

[6] R. Nyga and W. Neu, Double-pulse technique for optical emission spectroscopy of ablation plasmas of samples in liquids, Opt. Lett., vol. 18, p.747–749, May., (1993).

DOI: 10.1364/ol.18.000747

Google Scholar

[7] R. Sattmann, V. Sturm, and R. Noll, Laser-induced breakdown spectroscopy of steel samples using multiple Q-switch Nd: YAG laser pulses, J. Phys. D., vol. 28, p.2181–2187, Oct., (1995).

DOI: 10.1088/0022-3727/28/10/030

Google Scholar

[8] S. Nakamura, Y. Ito, K. Sone, H. Hiraga, and K. Kaneko, Determination of an Iron Suspension in Water by Laser-Induced Breakdown Spectroscopy with Two Sequential Laser Pulses, Anal. Chem., vol. 68, p.2981–2986, Sep., (1996).

DOI: 10.1021/ac9601167

Google Scholar

[9] A. E. Pichahchy, D. A. Cremers, and M. J. Ferris, Elemental analysis of metals under water using laser-induced breakdown spectroscopy, Spectrochim. Acta. B, vol. 52, p.25–39, Jan., (1997).

DOI: 10.1016/s0584-8547(96)01575-3

Google Scholar

[10] D. N. Stratis, K. L. Eland, and S. M. Angel, Dual-pulse LIBS using a pre-ablation spark for enhanced ablation and emission, Appl. Spectrosc., vol. 54, p.1270–1274, Sep., (2000).

DOI: 10.1366/0003702001951174

Google Scholar

[11] D. N. Stratis, K. L. Eland, and S. M. Angel, Effect of pulse delay time on a pre-ablation dual-pulse LIBS plasma, Appl. Spectrosc., vol. 55, p.1297–1303, Oct., (2001).

DOI: 10.1366/0003702011953649

Google Scholar

[12] A. Kuwako, Y. Uchida, K. Maeda, Supersensitive detection of sodium in water with use of dual-pulse laser-induced breakdown spectroscopy, Appl. Opt., vol. 42, no. 30, p.6052–6056, Oct., (2003).

DOI: 10.1364/ao.42.006052

Google Scholar