Dental Materials Journal
Online ISSN : 1881-1361
Print ISSN : 0287-4547
ISSN-L : 0287-4547
Original Paper
Fitness accuracy and retentive forces of milled titanium clasp
Ryota MARUOHidemasa SHIMPOKatsuhiko KIMOTOTohru HAYAKAWAHiromi MIURAChikahiro OHKUBO
Author information
JOURNAL FREE ACCESS

2022 Volume 41 Issue 3 Pages 414-420

Details
Abstract

Since cast titanium prostheses have many drawbacks, multi-directionally forged titanium grade 2 (MDF) was developed, and the application of the milling process was proposed for improving the titanium clasp. This in vitro study evaluated milled titanium clasps, including MDF titanium. Milling clasps were manufactured with commercially pure (CP) titanium grade 2 (CP 2), grade 4 (CP 4), Ti-6-Al-4V, and MDF. As a control, a CP 2 cast titanium clasp was fabricated in the conventional manner. No porosities and catastrophic failures were observed in the four milled titanium clasps. Fitness accuracy and retentive forces of milled CP 2 and CP 4 tended to be worse, and the milled MDF showed the higher retentive forces (12.45 N) than did cast and milled CP 2 clasps (9.32 N and 4.42 N). Milled titanium clasps can be recommended for longer-term clinical use as compared to cast clasps.

Content from these authors
© 2022 The Japanese Society for Dental Materials and Devices
Previous article Next article